Cargando…

SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study

BACKGROUND: SpO(2), heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units. Objective: to determine the relationship between the aforementioned parameters and the sta...

Descripción completa

Detalles Bibliográficos
Autores principales: Czeszyńska, Maria Beata, Sontowska, Agnieszka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10183777/
https://www.ncbi.nlm.nih.gov/pubmed/33165881
http://dx.doi.org/10.5114/ait.2020.100574
_version_ 1785042027846565888
author Czeszyńska, Maria Beata
Sontowska, Agnieszka
author_facet Czeszyńska, Maria Beata
Sontowska, Agnieszka
author_sort Czeszyńska, Maria Beata
collection PubMed
description BACKGROUND: SpO(2), heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units. Objective: to determine the relationship between the aforementioned parameters and the status of newborns depending on the outcome of the Infant Flow (I-F) therapy, and the development of complications in the form of pneumothorax. METHODS: A retrospective single-centre study covering the years 2009–2014. A total of 182 neonates, with mean gestational age 34.1 weeks and mean body weight 2226 g, were analysed. The minimum and maximum values of the evaluated parameters were analysed statistically according to the therapy outcome noted as success or failure. RESULTS: A successful outcome of I-F therapy (71.4%) was characterised by higher SpO(2) (93.3 ±7.28 vs. 85.9 ±14.77 at P < 0.001; 99.95 ±0.31 vs. 98.6 ±3.30 at P < 0.0001), lower heart rate (122.5 ±12.37 vs. 135.9 ±14.97 at P < 0.0001), and higher max systolic blood pressure (79.05 ±12.49 vs. 69.78 ±13.73 mm Hg at P < 0.0001), max diastolic blood pressure (57.03 ±9.31 vs. 50.41 ±13.82 mm Hg; P < 0.0003), and max as well as min mean arterial blood pressure (46.8 ±10.13 vs. 41.39 ±15.46 mm Hg; P < 0.001) (27.88 ±5.71 vs. 26.14 ±7.35 mm Hg; P < 0.02). CONCLUSIONS: In newborns suffering from respiratory failure and treated with I-F, higher SpO(2) values, lower heart rate, and higher arterial blood pressure coincide with success of the I-F therapy.
format Online
Article
Text
id pubmed-10183777
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-101837772023-05-17 SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study Czeszyńska, Maria Beata Sontowska, Agnieszka Anaesthesiol Intensive Ther Original and Clinical Articles BACKGROUND: SpO(2), heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units. Objective: to determine the relationship between the aforementioned parameters and the status of newborns depending on the outcome of the Infant Flow (I-F) therapy, and the development of complications in the form of pneumothorax. METHODS: A retrospective single-centre study covering the years 2009–2014. A total of 182 neonates, with mean gestational age 34.1 weeks and mean body weight 2226 g, were analysed. The minimum and maximum values of the evaluated parameters were analysed statistically according to the therapy outcome noted as success or failure. RESULTS: A successful outcome of I-F therapy (71.4%) was characterised by higher SpO(2) (93.3 ±7.28 vs. 85.9 ±14.77 at P < 0.001; 99.95 ±0.31 vs. 98.6 ±3.30 at P < 0.0001), lower heart rate (122.5 ±12.37 vs. 135.9 ±14.97 at P < 0.0001), and higher max systolic blood pressure (79.05 ±12.49 vs. 69.78 ±13.73 mm Hg at P < 0.0001), max diastolic blood pressure (57.03 ±9.31 vs. 50.41 ±13.82 mm Hg; P < 0.0003), and max as well as min mean arterial blood pressure (46.8 ±10.13 vs. 41.39 ±15.46 mm Hg; P < 0.001) (27.88 ±5.71 vs. 26.14 ±7.35 mm Hg; P < 0.02). CONCLUSIONS: In newborns suffering from respiratory failure and treated with I-F, higher SpO(2) values, lower heart rate, and higher arterial blood pressure coincide with success of the I-F therapy. Termedia Publishing House 2020-10-30 2020-10 /pmc/articles/PMC10183777/ /pubmed/33165881 http://dx.doi.org/10.5114/ait.2020.100574 Text en Copyright © Polish Society of Anaesthesiology and Intensive Therapy https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access journal, all articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) ), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original and Clinical Articles
Czeszyńska, Maria Beata
Sontowska, Agnieszka
SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
title SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
title_full SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
title_fullStr SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
title_full_unstemmed SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
title_short SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
title_sort spo(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study
topic Original and Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10183777/
https://www.ncbi.nlm.nih.gov/pubmed/33165881
http://dx.doi.org/10.5114/ait.2020.100574
work_keys_str_mv AT czeszynskamariabeata spo2heartrateandarterialbloodpressureduringsuccessfulorfailedapplicationofnoninvasiveventilationafterdeliveryasinglecentrestudy
AT sontowskaagnieszka spo2heartrateandarterialbloodpressureduringsuccessfulorfailedapplicationofnoninvasiveventilationafterdeliveryasinglecentrestudy