Cargando…
Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS
BACKGROUND: The Patient-Reported Outcomes Measurement Information System (PROMIS) has not been fully evaluated for outcomes assessment after hip arthroscopy to correct femoroacetabular impingement syndrome (FAIS). PURPOSE/HYPOTHESIS: The purpose of this study was to compare the accuracy of the PROMI...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10184234/ https://www.ncbi.nlm.nih.gov/pubmed/37197035 http://dx.doi.org/10.1177/23259671231168887 |
_version_ | 1785042124327092224 |
---|---|
author | Martin, RobRoy L. Harris, Joshua D. Ellis, Thomas Kollmorgen, Robert |
author_facet | Martin, RobRoy L. Harris, Joshua D. Ellis, Thomas Kollmorgen, Robert |
author_sort | Martin, RobRoy L. |
collection | PubMed |
description | BACKGROUND: The Patient-Reported Outcomes Measurement Information System (PROMIS) has not been fully evaluated for outcomes assessment after hip arthroscopy to correct femoroacetabular impingement syndrome (FAIS). PURPOSE/HYPOTHESIS: The purpose of this study was to compare the accuracy of the PROMIS Physical Function (PF) and Pain Interference (PI) subscales with the 12-Item International Hip Outcome Tool (iHOT-12) to define patients with 3 unique substantial clinical benefit (SCB) scores—patients who reported ≥80%, ≥90%, and 100% satisfaction at 1 year after hip arthroscopy for FAIS. We hypothesized that the iHOT-12 would be more accurate than the PROMIS-PF and PROMIS-PI subscales in identifying these 3 patient groups. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: We reviewed the records of patients who underwent hip arthroscopy for symptomatic FAIS at 3 centers from January 2019 through June 2021 and had 1-year clinical and radiographic follow-up data. Patients completed the iHOT-12, PROMIS-PF, and PROMIS-PI on initial assessment and at 1 year (±30 days) postoperatively. Postoperative satisfaction was reported on an 11-category scale with anchors defined as “0% satisfied” and “100% satisfied.” Receiver operator characteristic analysis was performed to determine the absolute SCB values for the iHOT-12 and PROMIS subscales that would most accurately identify those patients who reported ≥80%, ≥90%, and 100% satisfaction. Area under the curve (AUC) values and 95% CIs for the 3 instruments were compared. RESULTS: Included were 163 patients (111 [68%] women and 52 [32%] men), with a mean age of 26.1 years. Corresponding absolute SCB scores for patients who reported ≥80%, ≥90%, and 100% satisfaction were as follows: iHOT-12, 68.4, 72.1, 74.7; PROMIS-PF, 45, 47.7, 49.9; and PROMIS-PI, 55.9, 52.4, 51.9. The AUC ranged between 0.67 and 0.82, with overlapping 95% CIs indicating a minimal difference in accuracy between the 3 instruments. Sensitivity and specificity values ranged between 0.61 and 0.82. CONCLUSION: The PROMIS-PF and PROMIS-PI subscales were as accurate as the iHOT-12 in defining absolute SCB scores for patients reporting ≥80%, ≥90%, and 100% satisfaction at 1-year follow-up after hip arthroscopy for FAIS. |
format | Online Article Text |
id | pubmed-10184234 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-101842342023-05-16 Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS Martin, RobRoy L. Harris, Joshua D. Ellis, Thomas Kollmorgen, Robert Orthop J Sports Med Original Research BACKGROUND: The Patient-Reported Outcomes Measurement Information System (PROMIS) has not been fully evaluated for outcomes assessment after hip arthroscopy to correct femoroacetabular impingement syndrome (FAIS). PURPOSE/HYPOTHESIS: The purpose of this study was to compare the accuracy of the PROMIS Physical Function (PF) and Pain Interference (PI) subscales with the 12-Item International Hip Outcome Tool (iHOT-12) to define patients with 3 unique substantial clinical benefit (SCB) scores—patients who reported ≥80%, ≥90%, and 100% satisfaction at 1 year after hip arthroscopy for FAIS. We hypothesized that the iHOT-12 would be more accurate than the PROMIS-PF and PROMIS-PI subscales in identifying these 3 patient groups. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: We reviewed the records of patients who underwent hip arthroscopy for symptomatic FAIS at 3 centers from January 2019 through June 2021 and had 1-year clinical and radiographic follow-up data. Patients completed the iHOT-12, PROMIS-PF, and PROMIS-PI on initial assessment and at 1 year (±30 days) postoperatively. Postoperative satisfaction was reported on an 11-category scale with anchors defined as “0% satisfied” and “100% satisfied.” Receiver operator characteristic analysis was performed to determine the absolute SCB values for the iHOT-12 and PROMIS subscales that would most accurately identify those patients who reported ≥80%, ≥90%, and 100% satisfaction. Area under the curve (AUC) values and 95% CIs for the 3 instruments were compared. RESULTS: Included were 163 patients (111 [68%] women and 52 [32%] men), with a mean age of 26.1 years. Corresponding absolute SCB scores for patients who reported ≥80%, ≥90%, and 100% satisfaction were as follows: iHOT-12, 68.4, 72.1, 74.7; PROMIS-PF, 45, 47.7, 49.9; and PROMIS-PI, 55.9, 52.4, 51.9. The AUC ranged between 0.67 and 0.82, with overlapping 95% CIs indicating a minimal difference in accuracy between the 3 instruments. Sensitivity and specificity values ranged between 0.61 and 0.82. CONCLUSION: The PROMIS-PF and PROMIS-PI subscales were as accurate as the iHOT-12 in defining absolute SCB scores for patients reporting ≥80%, ≥90%, and 100% satisfaction at 1-year follow-up after hip arthroscopy for FAIS. SAGE Publications 2023-05-12 /pmc/articles/PMC10184234/ /pubmed/37197035 http://dx.doi.org/10.1177/23259671231168887 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Martin, RobRoy L. Harris, Joshua D. Ellis, Thomas Kollmorgen, Robert Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS |
title | Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS |
title_full | Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS |
title_fullStr | Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS |
title_full_unstemmed | Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS |
title_short | Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS |
title_sort | comparison of the promis and ihot-12 in determining satisfaction levels after hip arthroscopy for fais |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10184234/ https://www.ncbi.nlm.nih.gov/pubmed/37197035 http://dx.doi.org/10.1177/23259671231168887 |
work_keys_str_mv | AT martinrobroyl comparisonofthepromisandihot12indeterminingsatisfactionlevelsafterhiparthroscopyforfais AT harrisjoshuad comparisonofthepromisandihot12indeterminingsatisfactionlevelsafterhiparthroscopyforfais AT ellisthomas comparisonofthepromisandihot12indeterminingsatisfactionlevelsafterhiparthroscopyforfais AT kollmorgenrobert comparisonofthepromisandihot12indeterminingsatisfactionlevelsafterhiparthroscopyforfais |