Cargando…
Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI
INTRODUCTION: The Centiloid scale aims to harmonize amyloid beta (Aβ) positron emission tomography (PET) measures across different analysis methods. As Centiloids were created using PET/computerized tomography (CT) data and are influenced by scanner differences, we investigated the Centiloid transfo...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10186069/ https://www.ncbi.nlm.nih.gov/pubmed/37201176 http://dx.doi.org/10.1002/dad2.12434 |
_version_ | 1785042493689036800 |
---|---|
author | Coath, William Modat, Marc Cardoso, M. Jorge Markiewicz, Pawel J. Lane, Christopher A. Parker, Thomas D. Keshavan, Ashvini Buchanan, Sarah M. Keuss, Sarah E. Harris, Matthew J. Burgos, Ninon Dickson, John Barnes, Anna Thomas, David L. Beasley, Daniel Malone, Ian B. Wong, Andrew Erlandsson, Kjell Thomas, Benjamin A. Schöll, Michael Ourselin, Sebastien Richards, Marcus Fox, Nick C. Schott, Jonathan M. Cash, David M. |
author_facet | Coath, William Modat, Marc Cardoso, M. Jorge Markiewicz, Pawel J. Lane, Christopher A. Parker, Thomas D. Keshavan, Ashvini Buchanan, Sarah M. Keuss, Sarah E. Harris, Matthew J. Burgos, Ninon Dickson, John Barnes, Anna Thomas, David L. Beasley, Daniel Malone, Ian B. Wong, Andrew Erlandsson, Kjell Thomas, Benjamin A. Schöll, Michael Ourselin, Sebastien Richards, Marcus Fox, Nick C. Schott, Jonathan M. Cash, David M. |
author_sort | Coath, William |
collection | PubMed |
description | INTRODUCTION: The Centiloid scale aims to harmonize amyloid beta (Aβ) positron emission tomography (PET) measures across different analysis methods. As Centiloids were created using PET/computerized tomography (CT) data and are influenced by scanner differences, we investigated the Centiloid transformation with data from Insight 46 acquired with PET/magnetic resonanceimaging (MRI). METHODS: We transformed standardized uptake value ratios (SUVRs) from 432 florbetapir PET/MRI scans processed using whole cerebellum (WC) and white matter (WM) references, with and without partial volume correction. Gaussian‐mixture‐modelling–derived cutpoints for Aβ PET positivity were converted. RESULTS: The Centiloid cutpoint was 14.2 for WC SUVRs. The relationship between WM and WC uptake differed between the calibration and testing datasets, producing implausibly low WM‐based Centiloids. Linear adjustment produced a WM‐based cutpoint of 18.1. DISCUSSION: Transformation of PET/MRI florbetapir data to Centiloids is valid. However, further understanding of the effects of acquisition or biological factors on the transformation using a WM reference is needed. HIGHLIGHTS: Centiloid conversion of amyloid beta positron emission tomography (PET) data aims to standardize results. Centiloid values can be influenced by differences in acquisition. We converted florbetapir PET/magnetic resonance imaging data from a large birth cohort. Whole cerebellum referenced values could be reliably transformed to Centiloids. White matter referenced values may be less generalizable between datasets. |
format | Online Article Text |
id | pubmed-10186069 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101860692023-05-17 Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI Coath, William Modat, Marc Cardoso, M. Jorge Markiewicz, Pawel J. Lane, Christopher A. Parker, Thomas D. Keshavan, Ashvini Buchanan, Sarah M. Keuss, Sarah E. Harris, Matthew J. Burgos, Ninon Dickson, John Barnes, Anna Thomas, David L. Beasley, Daniel Malone, Ian B. Wong, Andrew Erlandsson, Kjell Thomas, Benjamin A. Schöll, Michael Ourselin, Sebastien Richards, Marcus Fox, Nick C. Schott, Jonathan M. Cash, David M. Alzheimers Dement (Amst) Research Articles INTRODUCTION: The Centiloid scale aims to harmonize amyloid beta (Aβ) positron emission tomography (PET) measures across different analysis methods. As Centiloids were created using PET/computerized tomography (CT) data and are influenced by scanner differences, we investigated the Centiloid transformation with data from Insight 46 acquired with PET/magnetic resonanceimaging (MRI). METHODS: We transformed standardized uptake value ratios (SUVRs) from 432 florbetapir PET/MRI scans processed using whole cerebellum (WC) and white matter (WM) references, with and without partial volume correction. Gaussian‐mixture‐modelling–derived cutpoints for Aβ PET positivity were converted. RESULTS: The Centiloid cutpoint was 14.2 for WC SUVRs. The relationship between WM and WC uptake differed between the calibration and testing datasets, producing implausibly low WM‐based Centiloids. Linear adjustment produced a WM‐based cutpoint of 18.1. DISCUSSION: Transformation of PET/MRI florbetapir data to Centiloids is valid. However, further understanding of the effects of acquisition or biological factors on the transformation using a WM reference is needed. HIGHLIGHTS: Centiloid conversion of amyloid beta positron emission tomography (PET) data aims to standardize results. Centiloid values can be influenced by differences in acquisition. We converted florbetapir PET/magnetic resonance imaging data from a large birth cohort. Whole cerebellum referenced values could be reliably transformed to Centiloids. White matter referenced values may be less generalizable between datasets. John Wiley and Sons Inc. 2023-05-16 /pmc/articles/PMC10186069/ /pubmed/37201176 http://dx.doi.org/10.1002/dad2.12434 Text en © 2023 The Authors. Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring published by Wiley Periodicals, LLC on behalf of Alzheimer's Association. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Research Articles Coath, William Modat, Marc Cardoso, M. Jorge Markiewicz, Pawel J. Lane, Christopher A. Parker, Thomas D. Keshavan, Ashvini Buchanan, Sarah M. Keuss, Sarah E. Harris, Matthew J. Burgos, Ninon Dickson, John Barnes, Anna Thomas, David L. Beasley, Daniel Malone, Ian B. Wong, Andrew Erlandsson, Kjell Thomas, Benjamin A. Schöll, Michael Ourselin, Sebastien Richards, Marcus Fox, Nick C. Schott, Jonathan M. Cash, David M. Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI |
title | Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI |
title_full | Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI |
title_fullStr | Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI |
title_full_unstemmed | Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI |
title_short | Operationalizing the centiloid scale for [(18)F]florbetapir PET studies on PET/MRI |
title_sort | operationalizing the centiloid scale for [(18)f]florbetapir pet studies on pet/mri |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10186069/ https://www.ncbi.nlm.nih.gov/pubmed/37201176 http://dx.doi.org/10.1002/dad2.12434 |
work_keys_str_mv | AT coathwilliam operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT modatmarc operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT cardosomjorge operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT markiewiczpawelj operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT lanechristophera operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT parkerthomasd operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT keshavanashvini operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT buchanansarahm operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT keusssarahe operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT harrismatthewj operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT burgosninon operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT dicksonjohn operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT barnesanna operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT thomasdavidl operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT beasleydaniel operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT maloneianb operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT wongandrew operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT erlandssonkjell operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT thomasbenjamina operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT schollmichael operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT ourselinsebastien operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT richardsmarcus operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT foxnickc operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT schottjonathanm operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT cashdavidm operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri AT operationalizingthecentiloidscalefor18fflorbetapirpetstudiesonpetmri |