Cargando…
Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery
Congenital pulmonary airway malformation (CPAM) is a developmental malformation that affects the lung parenchyma, especially terminal respiratory bronchioles. This paper reports a case of an infant diagnosed with CPAM who underwent stapleless thoracoscopic lobectomy using Hem-o-Lok clips(®). Compute...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10187473/ https://www.ncbi.nlm.nih.gov/pubmed/37201108 http://dx.doi.org/10.1093/jscr/rjad247 |
_version_ | 1785042742702768128 |
---|---|
author | Masahata, Kazunori Uga, Naoko Nomura, Motonari Kamiyama, Masafumi Okuyama, Hiroomi |
author_facet | Masahata, Kazunori Uga, Naoko Nomura, Motonari Kamiyama, Masafumi Okuyama, Hiroomi |
author_sort | Masahata, Kazunori |
collection | PubMed |
description | Congenital pulmonary airway malformation (CPAM) is a developmental malformation that affects the lung parenchyma, especially terminal respiratory bronchioles. This paper reports a case of an infant diagnosed with CPAM who underwent stapleless thoracoscopic lobectomy using Hem-o-Lok clips(®). Computed tomography showed cystic pulmonary lesions in the left lower lobe. Thoracoscopic lobectomy was performed at the age of 1 year and 3 months. During surgery, the hilar vasculature was treated using either Hem-o-Lok(®) clips or a LigaSure vessel sealing system. The lower lobe bronchus was divided using double Hem-o-Lok(®) clips proximally. The surgery was successfully completed. The patient’s postoperative course was uneventful, and there were no complications. This technique can be easily performed as a thoracoscopic lobectomy with the potential benefits of safe and effective procedures for bronchus closure and vascular sealing in the small working space of pediatric patients. |
format | Online Article Text |
id | pubmed-10187473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-101874732023-05-17 Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery Masahata, Kazunori Uga, Naoko Nomura, Motonari Kamiyama, Masafumi Okuyama, Hiroomi J Surg Case Rep Surgical Technique Congenital pulmonary airway malformation (CPAM) is a developmental malformation that affects the lung parenchyma, especially terminal respiratory bronchioles. This paper reports a case of an infant diagnosed with CPAM who underwent stapleless thoracoscopic lobectomy using Hem-o-Lok clips(®). Computed tomography showed cystic pulmonary lesions in the left lower lobe. Thoracoscopic lobectomy was performed at the age of 1 year and 3 months. During surgery, the hilar vasculature was treated using either Hem-o-Lok(®) clips or a LigaSure vessel sealing system. The lower lobe bronchus was divided using double Hem-o-Lok(®) clips proximally. The surgery was successfully completed. The patient’s postoperative course was uneventful, and there were no complications. This technique can be easily performed as a thoracoscopic lobectomy with the potential benefits of safe and effective procedures for bronchus closure and vascular sealing in the small working space of pediatric patients. Oxford University Press 2023-05-15 /pmc/articles/PMC10187473/ /pubmed/37201108 http://dx.doi.org/10.1093/jscr/rjad247 Text en Published by Oxford University Press and JSCR Publishing Ltd. © The Author(s) 2023. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Surgical Technique Masahata, Kazunori Uga, Naoko Nomura, Motonari Kamiyama, Masafumi Okuyama, Hiroomi Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
title | Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
title_full | Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
title_fullStr | Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
title_full_unstemmed | Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
title_short | Stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
title_sort | stapleless thoracoscopic lobectomy for congenital pulmonary airway malformation: a simple technique in thoracoscopic surgery |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10187473/ https://www.ncbi.nlm.nih.gov/pubmed/37201108 http://dx.doi.org/10.1093/jscr/rjad247 |
work_keys_str_mv | AT masahatakazunori staplelessthoracoscopiclobectomyforcongenitalpulmonaryairwaymalformationasimpletechniqueinthoracoscopicsurgery AT uganaoko staplelessthoracoscopiclobectomyforcongenitalpulmonaryairwaymalformationasimpletechniqueinthoracoscopicsurgery AT nomuramotonari staplelessthoracoscopiclobectomyforcongenitalpulmonaryairwaymalformationasimpletechniqueinthoracoscopicsurgery AT kamiyamamasafumi staplelessthoracoscopiclobectomyforcongenitalpulmonaryairwaymalformationasimpletechniqueinthoracoscopicsurgery AT okuyamahiroomi staplelessthoracoscopiclobectomyforcongenitalpulmonaryairwaymalformationasimpletechniqueinthoracoscopicsurgery |