Cargando…
Hospital utilisation and the costs associated with complications of ICD implantation in a contemporary primary prevention cohort
INTRODUCTION: Implantation of an implantable cardioverter defibrillator (ICD) is standard care for primary prevention of sudden cardiac death. However, ICD-related complications are increasing as the population of ICD recipients grows. METHODS: ICD-related complications in a national DO-IT Registry...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10188874/ https://www.ncbi.nlm.nih.gov/pubmed/36434382 http://dx.doi.org/10.1007/s12471-022-01733-4 |
Sumario: | INTRODUCTION: Implantation of an implantable cardioverter defibrillator (ICD) is standard care for primary prevention of sudden cardiac death. However, ICD-related complications are increasing as the population of ICD recipients grows. METHODS: ICD-related complications in a national DO-IT Registry cohort of 1442 primary prevention ICD patients were assessed in terms of additional use of hospital care resources and costs. RESULTS: During a median follow-up of 28.7 months (IQR 25.2–33.7) one or more complications occurred in 13.5% of patients. A complication resulted in a surgical intervention in 53% of cases and required on average 3.65 additional hospital days. The additional hospital costs were €6,876 per complication or €8,110 per patient, to which clinical re-interventions and additional hospital days contributed most. Per category of complications, infections required most hospital utilisation and were most expensive at an average of €22,892. The mean costs were €5,800 for lead-related complications, €2,291 for pocket-related complications and €5,619 for complications due to other causes. We estimate that the total yearly incidence-based costs in the Netherlands for hospital management of ICD-related complications following ICD implantation for primary prevention are €2.7 million. CONCLUSION: Complications following ICD implantation are related to a substantial additional need for hospital resources. When performing cost-effectiveness analyses of ICD implantation, including the costs associated with complications, one should be aware that real-world complication rates may deviate from trial data. Considering the economic implications, strategies to reduce the incidence of complications are encouraged. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s12471-022-01733-4) contains supplementary material, which is available to authorized users. |
---|