Cargando…

Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)

BACKGROUND: Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determ...

Descripción completa

Detalles Bibliográficos
Autores principales: Khamis, Mohamed Moataz, Zakaria, Niveen Hazem, Farrag, Khaled Mohamed, Abolgheit, Salma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10190041/
https://www.ncbi.nlm.nih.gov/pubmed/37198623
http://dx.doi.org/10.1186/s12903-023-02958-4
_version_ 1785043205862981632
author Khamis, Mohamed Moataz
Zakaria, Niveen Hazem
Farrag, Khaled Mohamed
Abolgheit, Salma
author_facet Khamis, Mohamed Moataz
Zakaria, Niveen Hazem
Farrag, Khaled Mohamed
Abolgheit, Salma
author_sort Khamis, Mohamed Moataz
collection PubMed
description BACKGROUND: Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of splinted restorations with engaging preparable abutments or titanium base abutments. METHODS: Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0 to 20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0–10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman’s rank correlation coefficient. RESULTS: The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman’s rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased. CONCLUSIONS: Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees.
format Online
Article
Text
id pubmed-10190041
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101900412023-05-18 Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study) Khamis, Mohamed Moataz Zakaria, Niveen Hazem Farrag, Khaled Mohamed Abolgheit, Salma BMC Oral Health Research BACKGROUND: Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of splinted restorations with engaging preparable abutments or titanium base abutments. METHODS: Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0 to 20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0–10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman’s rank correlation coefficient. RESULTS: The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman’s rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased. CONCLUSIONS: Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees. BioMed Central 2023-05-17 /pmc/articles/PMC10190041/ /pubmed/37198623 http://dx.doi.org/10.1186/s12903-023-02958-4 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Khamis, Mohamed Moataz
Zakaria, Niveen Hazem
Farrag, Khaled Mohamed
Abolgheit, Salma
Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
title Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
title_full Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
title_fullStr Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
title_full_unstemmed Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
title_short Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
title_sort evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study)
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10190041/
https://www.ncbi.nlm.nih.gov/pubmed/37198623
http://dx.doi.org/10.1186/s12903-023-02958-4
work_keys_str_mv AT khamismohamedmoataz evaluationofthedislodgementforceofsplintedrestorationswithengagingconicalabutmentsovermultiplenonparallelimplantsinvitrostudy
AT zakarianiveenhazem evaluationofthedislodgementforceofsplintedrestorationswithengagingconicalabutmentsovermultiplenonparallelimplantsinvitrostudy
AT farragkhaledmohamed evaluationofthedislodgementforceofsplintedrestorationswithengagingconicalabutmentsovermultiplenonparallelimplantsinvitrostudy
AT abolgheitsalma evaluationofthedislodgementforceofsplintedrestorationswithengagingconicalabutmentsovermultiplenonparallelimplantsinvitrostudy