DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study
AIM: The present investigation aimed at assessing the diagnostic accuracy of DIAGNOdent compared to the International Caries Detection and Assessment System-II (ICDAS-II) in the detection of facial, smooth surface noncavitated carious lesions. SETTINGS AND DESIGN: Sixty patients were enrolled in the...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10190091/ https://www.ncbi.nlm.nih.gov/pubmed/37205891 http://dx.doi.org/10.4103/jcd.jcd_575_22 |
_version_ | 1785043216096034816 |
---|---|
author | Shaalan, Omar Osama |
author_facet | Shaalan, Omar Osama |
author_sort | Shaalan, Omar Osama |
collection | PubMed |
description | AIM: The present investigation aimed at assessing the diagnostic accuracy of DIAGNOdent compared to the International Caries Detection and Assessment System-II (ICDAS-II) in the detection of facial, smooth surface noncavitated carious lesions. SETTINGS AND DESIGN: Sixty patients were enrolled in the current study according to the eligibility criteria. There were 161 teeth with noncavitated, white spot carious lesions and 32 sound teeth. MATERIALS AND METHODS: Before examination, teeth were cleaned and polished and all patients were assessed under standardized operating conditions: preset dental unit position, operating light, and prolonged air drying (approximately 5 s). All teeth were assessed by two calibrated examiners individually without any contact using ICDAS-II and DIAGNOdent. STATISTICAL ANALYSIS: The diagnostic accuracy of DIAGNOdent device was determined, including sensitivity, specificity, overall accuracy, positive and negative predictive values, and receiver operating characteristic curve analysis. Chi-square test was conducted to compare the distribution of ICDAS-II and DIAGNOdent scores. Inter-observer agreement between assessors was evaluated using Cohen's kappa test. RESULTS: In the current study, DIAGNOdent had an overall accuracy of 84.45% with sensitivity and specificity of 87.58% and 96.87%, respectively, and +PV and −PV of 97.7% and 83.9%, respectively, when score 0 represented sound tooth surface, while scores 1 and 2 were considered clinically noncavitated carious lesions. Moreover, when only ICDAS score 1 was considered representing first visual change in enamel, DIAGNOdent had an accuracy of 74.15% with sensitivity and specificity of 83.53% and 90.62%, respectively, and +PV and −PV of 93% and 78.6%, respectively. In the present study, when only ICDAS score 2 was considered representing distinct visual change in enamel, DIAGNOdent had an accuracy of 100% with sensitivity and specificity of 100% and 100%, respectively, and +PV and −PV of 100% and 100%, respectively. CONCLUSIONS: The overall performance of DIAGNOdent was equivalent to the visual inspection using ICDAS-II. DIAGNOdent might be considered a useful adjunctive device for detection and monitoring development of noncavitated carious lesions on facial smooth surfaces. |
format | Online Article Text |
id | pubmed-10190091 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-101900912023-05-18 DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study Shaalan, Omar Osama J Conserv Dent Original Article AIM: The present investigation aimed at assessing the diagnostic accuracy of DIAGNOdent compared to the International Caries Detection and Assessment System-II (ICDAS-II) in the detection of facial, smooth surface noncavitated carious lesions. SETTINGS AND DESIGN: Sixty patients were enrolled in the current study according to the eligibility criteria. There were 161 teeth with noncavitated, white spot carious lesions and 32 sound teeth. MATERIALS AND METHODS: Before examination, teeth were cleaned and polished and all patients were assessed under standardized operating conditions: preset dental unit position, operating light, and prolonged air drying (approximately 5 s). All teeth were assessed by two calibrated examiners individually without any contact using ICDAS-II and DIAGNOdent. STATISTICAL ANALYSIS: The diagnostic accuracy of DIAGNOdent device was determined, including sensitivity, specificity, overall accuracy, positive and negative predictive values, and receiver operating characteristic curve analysis. Chi-square test was conducted to compare the distribution of ICDAS-II and DIAGNOdent scores. Inter-observer agreement between assessors was evaluated using Cohen's kappa test. RESULTS: In the current study, DIAGNOdent had an overall accuracy of 84.45% with sensitivity and specificity of 87.58% and 96.87%, respectively, and +PV and −PV of 97.7% and 83.9%, respectively, when score 0 represented sound tooth surface, while scores 1 and 2 were considered clinically noncavitated carious lesions. Moreover, when only ICDAS score 1 was considered representing first visual change in enamel, DIAGNOdent had an accuracy of 74.15% with sensitivity and specificity of 83.53% and 90.62%, respectively, and +PV and −PV of 93% and 78.6%, respectively. In the present study, when only ICDAS score 2 was considered representing distinct visual change in enamel, DIAGNOdent had an accuracy of 100% with sensitivity and specificity of 100% and 100%, respectively, and +PV and −PV of 100% and 100%, respectively. CONCLUSIONS: The overall performance of DIAGNOdent was equivalent to the visual inspection using ICDAS-II. DIAGNOdent might be considered a useful adjunctive device for detection and monitoring development of noncavitated carious lesions on facial smooth surfaces. Wolters Kluwer - Medknow 2023 2023-03-16 /pmc/articles/PMC10190091/ /pubmed/37205891 http://dx.doi.org/10.4103/jcd.jcd_575_22 Text en Copyright: © 2023 Journal of Conservative Dentistry https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Shaalan, Omar Osama DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study |
title | DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study |
title_full | DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study |
title_fullStr | DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study |
title_full_unstemmed | DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study |
title_short | DIAGNOdent versus International Caries Detection and Assessment System in detection of incipient carious lesions: A diagnostic accuracy study |
title_sort | diagnodent versus international caries detection and assessment system in detection of incipient carious lesions: a diagnostic accuracy study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10190091/ https://www.ncbi.nlm.nih.gov/pubmed/37205891 http://dx.doi.org/10.4103/jcd.jcd_575_22 |
work_keys_str_mv | AT shaalanomarosama diagnodentversusinternationalcariesdetectionandassessmentsystemindetectionofincipientcariouslesionsadiagnosticaccuracystudy |