Cargando…
Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures
BACKGROUND: Hip fractures in the elderly population are common and the number of patients is rising. For young and geriatric patients with undisplaced fractures osteosynthesis is the primary type of treatment. The dynamic hip screw (DHS) is around for many years and proved its value especially in di...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10191950/ https://www.ncbi.nlm.nih.gov/pubmed/35867115 http://dx.doi.org/10.1007/s00402-022-04551-w |
_version_ | 1785043556559224832 |
---|---|
author | Schuetze, Konrad Burkhardt, Jakob Pankratz, Carlos Eickhoff, Alexander Boehringer, Alexander Degenhart, Christina Gebhard, Florian Cintean, Raffael |
author_facet | Schuetze, Konrad Burkhardt, Jakob Pankratz, Carlos Eickhoff, Alexander Boehringer, Alexander Degenhart, Christina Gebhard, Florian Cintean, Raffael |
author_sort | Schuetze, Konrad |
collection | PubMed |
description | BACKGROUND: Hip fractures in the elderly population are common and the number of patients is rising. For young and geriatric patients with undisplaced fractures osteosynthesis is the primary type of treatment. The dynamic hip screw (DHS) is around for many years and proved its value especially in displaced fractures. Since 2018 the femoral neck system (FNS) is available as an alternative showing promising biomechanical results. The aim of this study is to evaluate clinical results of the FNS and compare it to the DHS. MATERIALS AND METHODS: Patients older than 18 years with Garden I–IV fractures that were treated with osteosynthesis in a level 1 trauma center were included in the study. Between January 2015 and March 2021, all patients treated with FNS (1-hole plate, DePuy-Synthes, Zuchwil, Switzerland) or DHS (2-hole plate, DePuy-Synthes, Zuchwil, Switzerland) for proximal femur fractures were included in the study. Closed reduction was achieved using a traction table. All operations were carried out by experienced orthopedic trauma surgeons. Primary outcome measures were rate of implant failure (cut out) and surgical complications (hematoma, infection). Secondary outcome measures were Hb-difference, length of hospital stay and mortality. RESULTS: Overall, 221 patients were included in the study. 113 were treated with FNS, 108 with DHS. Mean age was 69 ± 14 years. There were 17.2% Garden I, 47.5% Garden II, 26.7% Garden III and 8.6% Garden IV fractures. No difference between the groups for age, body mass index (BMI), Charlson comorbidity index (CCI), time to surgery, Pauwels and Garden classification, rate of optimal blade position or tip apex distance was found. FNS showed lower pre- to postoperative Hb-difference (1.4 ± 1.1 g/l vs. 2.1 ± 1.4 g/l; p < 0.05), shorter operating time (36.3 ± 11.6 min vs. 54.7 ± 17.4 min; p < 0.05) and hospital stay (8.8 ± 4.3 d vs. 11.2 ± 6.8 d; p < 0.05). Surgical complications (FNS 13.3% vs. DHS 18.4%, p > 0.05), rate of cut out (FNS 12.4% vs. DHS 10.2%, p > 0.05) and mortality (FNS 3.5%; DHS 0.9%; p > 0.05) showed no difference between the groups. Logistic regression showed that poor blade position was the only significant predictor for cut out and increased the risk by factor 7. Implant related infection (n = 3) and hematoma/seroma (n = 6) that needed revision was only seen in DHS group. CONCLUSION: FNS proved to be as reliable as DHS in all patients with hip fractures. Not the type of implant but blade positioning is still key to prevent implant failure. Still due to minimal invasive approach implant related infections and postoperative hematomas might have been prevented using the FNS. |
format | Online Article Text |
id | pubmed-10191950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-101919502023-05-19 Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures Schuetze, Konrad Burkhardt, Jakob Pankratz, Carlos Eickhoff, Alexander Boehringer, Alexander Degenhart, Christina Gebhard, Florian Cintean, Raffael Arch Orthop Trauma Surg Trauma Surgery BACKGROUND: Hip fractures in the elderly population are common and the number of patients is rising. For young and geriatric patients with undisplaced fractures osteosynthesis is the primary type of treatment. The dynamic hip screw (DHS) is around for many years and proved its value especially in displaced fractures. Since 2018 the femoral neck system (FNS) is available as an alternative showing promising biomechanical results. The aim of this study is to evaluate clinical results of the FNS and compare it to the DHS. MATERIALS AND METHODS: Patients older than 18 years with Garden I–IV fractures that were treated with osteosynthesis in a level 1 trauma center were included in the study. Between January 2015 and March 2021, all patients treated with FNS (1-hole plate, DePuy-Synthes, Zuchwil, Switzerland) or DHS (2-hole plate, DePuy-Synthes, Zuchwil, Switzerland) for proximal femur fractures were included in the study. Closed reduction was achieved using a traction table. All operations were carried out by experienced orthopedic trauma surgeons. Primary outcome measures were rate of implant failure (cut out) and surgical complications (hematoma, infection). Secondary outcome measures were Hb-difference, length of hospital stay and mortality. RESULTS: Overall, 221 patients were included in the study. 113 were treated with FNS, 108 with DHS. Mean age was 69 ± 14 years. There were 17.2% Garden I, 47.5% Garden II, 26.7% Garden III and 8.6% Garden IV fractures. No difference between the groups for age, body mass index (BMI), Charlson comorbidity index (CCI), time to surgery, Pauwels and Garden classification, rate of optimal blade position or tip apex distance was found. FNS showed lower pre- to postoperative Hb-difference (1.4 ± 1.1 g/l vs. 2.1 ± 1.4 g/l; p < 0.05), shorter operating time (36.3 ± 11.6 min vs. 54.7 ± 17.4 min; p < 0.05) and hospital stay (8.8 ± 4.3 d vs. 11.2 ± 6.8 d; p < 0.05). Surgical complications (FNS 13.3% vs. DHS 18.4%, p > 0.05), rate of cut out (FNS 12.4% vs. DHS 10.2%, p > 0.05) and mortality (FNS 3.5%; DHS 0.9%; p > 0.05) showed no difference between the groups. Logistic regression showed that poor blade position was the only significant predictor for cut out and increased the risk by factor 7. Implant related infection (n = 3) and hematoma/seroma (n = 6) that needed revision was only seen in DHS group. CONCLUSION: FNS proved to be as reliable as DHS in all patients with hip fractures. Not the type of implant but blade positioning is still key to prevent implant failure. Still due to minimal invasive approach implant related infections and postoperative hematomas might have been prevented using the FNS. Springer Berlin Heidelberg 2022-07-22 2023 /pmc/articles/PMC10191950/ /pubmed/35867115 http://dx.doi.org/10.1007/s00402-022-04551-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Trauma Surgery Schuetze, Konrad Burkhardt, Jakob Pankratz, Carlos Eickhoff, Alexander Boehringer, Alexander Degenhart, Christina Gebhard, Florian Cintean, Raffael Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
title | Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
title_full | Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
title_fullStr | Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
title_full_unstemmed | Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
title_short | Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
title_sort | is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures |
topic | Trauma Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10191950/ https://www.ncbi.nlm.nih.gov/pubmed/35867115 http://dx.doi.org/10.1007/s00402-022-04551-w |
work_keys_str_mv | AT schuetzekonrad isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT burkhardtjakob isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT pankratzcarlos isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT eickhoffalexander isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT boehringeralexander isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT degenhartchristina isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT gebhardflorian isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures AT cinteanraffael isnewalwaysbettercomparisonofthefemoralnecksystemandthedynamichipscrewinthetreatmentoffemoralneckfractures |