Cargando…

Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine

INTRODUCTION: In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. MATERIALS AND METHODS: Posterior instrumentation procedures between 2010 and 2015 were retrospe...

Descripción completa

Detalles Bibliográficos
Autores principales: Conrads, Nora, Grunz, Jan-Peter, Huflage, Henner, Luetkens, Karsten Sebastian, Feldle, Philipp, Grunz, Katharina, Köhler, Stefan, Westermaier, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10191982/
https://www.ncbi.nlm.nih.gov/pubmed/35794344
http://dx.doi.org/10.1007/s00402-022-04514-1
_version_ 1785043562160717824
author Conrads, Nora
Grunz, Jan-Peter
Huflage, Henner
Luetkens, Karsten Sebastian
Feldle, Philipp
Grunz, Katharina
Köhler, Stefan
Westermaier, Thomas
author_facet Conrads, Nora
Grunz, Jan-Peter
Huflage, Henner
Luetkens, Karsten Sebastian
Feldle, Philipp
Grunz, Katharina
Köhler, Stefan
Westermaier, Thomas
author_sort Conrads, Nora
collection PubMed
description INTRODUCTION: In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. MATERIALS AND METHODS: Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. RESULTS: Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. CONCLUSIONS: Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required.
format Online
Article
Text
id pubmed-10191982
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-101919822023-05-19 Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine Conrads, Nora Grunz, Jan-Peter Huflage, Henner Luetkens, Karsten Sebastian Feldle, Philipp Grunz, Katharina Köhler, Stefan Westermaier, Thomas Arch Orthop Trauma Surg Orthopaedic Surgery INTRODUCTION: In spinal surgery, precise instrumentation is essential. This study aims to evaluate the accuracy of navigated, O-arm-controlled screw positioning in thoracic and lumbar spine instabilities. MATERIALS AND METHODS: Posterior instrumentation procedures between 2010 and 2015 were retrospectively analyzed. Pedicle screws were placed using 3D rotational fluoroscopy and neuronavigation. Accuracy of screw placement was assessed using a 6-grade scoring system. In addition, screw length was analyzed in relation to the vertebral body diameter. Intra- and postoperative revision rates were recorded. RESULTS: Thoracic and lumbar spine surgery was performed in 285 patients. Of 1704 pedicle screws, 1621 (95.1%) showed excellent positioning in 3D rotational fluoroscopy imaging. The lateral rim of either pedicle or vertebral body was protruded in 25 (1.5%) and 28 screws (1.6%), while the midline of the vertebral body was crossed in 8 screws (0.5%). Furthermore, 11 screws each (0.6%) fulfilled the criteria of full lateral and medial displacement. The median relative screw length was 92.6%. Intraoperative revision resulted in excellent positioning in 58 of 71 screws. Follow-up surgery due to missed primary malposition had to be performed for two screws in the same patient. Postsurgical symptom relief was reported in 82.1% of patients, whereas neurological deterioration occurred in 8.9% of cases with neurological follow-up. CONCLUSIONS: Combination of neuronavigation and 3D rotational fluoroscopy control ensures excellent accuracy in pedicle screw positioning. As misplaced screws can be detected reliably and revised intraoperatively, repeated surgery for screw malposition is rarely required. Springer Berlin Heidelberg 2022-07-06 2023 /pmc/articles/PMC10191982/ /pubmed/35794344 http://dx.doi.org/10.1007/s00402-022-04514-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Orthopaedic Surgery
Conrads, Nora
Grunz, Jan-Peter
Huflage, Henner
Luetkens, Karsten Sebastian
Feldle, Philipp
Grunz, Katharina
Köhler, Stefan
Westermaier, Thomas
Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
title Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
title_full Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
title_fullStr Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
title_full_unstemmed Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
title_short Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
title_sort accuracy of pedicle screw placement using neuronavigation based on intraoperative 3d rotational fluoroscopy in the thoracic and lumbar spine
topic Orthopaedic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10191982/
https://www.ncbi.nlm.nih.gov/pubmed/35794344
http://dx.doi.org/10.1007/s00402-022-04514-1
work_keys_str_mv AT conradsnora accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT grunzjanpeter accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT huflagehenner accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT luetkenskarstensebastian accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT feldlephilipp accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT grunzkatharina accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT kohlerstefan accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine
AT westermaierthomas accuracyofpediclescrewplacementusingneuronavigationbasedonintraoperative3drotationalfluoroscopyinthethoracicandlumbarspine