Cargando…

Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker

One of the cardiac biomarkers, myoglobin (Mb), is important in the rapid identification of cardio-vascular disorders. Therefore, point-of-care monitoring is essential. Pursuing this goal, a robust, reliable, and affordable paper-based analytical apparatus for potentiometric sensing has been develope...

Descripción completa

Detalles Bibliográficos
Autores principales: Almehizia, Abdulrahman A., Naglah, Ahmed M., Alrasheed, Lamees S., Alanazi, Mashael G., Amr, Abdel El-Galil E., Kamel, Ayman H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193383/
https://www.ncbi.nlm.nih.gov/pubmed/37213337
http://dx.doi.org/10.1039/d3ra02375c
_version_ 1785043825469685760
author Almehizia, Abdulrahman A.
Naglah, Ahmed M.
Alrasheed, Lamees S.
Alanazi, Mashael G.
Amr, Abdel El-Galil E.
Kamel, Ayman H.
author_facet Almehizia, Abdulrahman A.
Naglah, Ahmed M.
Alrasheed, Lamees S.
Alanazi, Mashael G.
Amr, Abdel El-Galil E.
Kamel, Ayman H.
author_sort Almehizia, Abdulrahman A.
collection PubMed
description One of the cardiac biomarkers, myoglobin (Mb), is important in the rapid identification of cardio-vascular disorders. Therefore, point-of-care monitoring is essential. Pursuing this goal, a robust, reliable, and affordable paper-based analytical apparatus for potentiometric sensing has been developed and characterized. The molecular imprint technique was used to create a customized biomimetic antibody for myoglobin (Mb) on the surface of carboxylated multiwalled carbon nanotubes (MWCNT–COOH). This was accomplished by attaching Mb to carboxylated MWCNTs' surfaces and then filling the empty spaces through the mild polymerization of acrylamide in N,N-methylenebisacrylamide and ammonium persulphate. The modification of the MWCNTs' surface was verified by SEM and FTIR analysis. A hydrophobic paper substrate coated with fluorinated alkyl silane (CF(3)(CF(2))(7)CH(2)CH(2)SiCl(3), CF(10)) has been coupled with a printed all–solid–state Ag/AgCl reference electrode. The presented sensors showed a linear range of 5.0 × 10(−8) to 1.0 × 10(−4) M with a potentiometric slope of −57.1 ± 0.3 mV decade(−1) (R(2) = 0.9998) and a detection limit of 28 nM at pH 4. Compared to creatinine, sucrose, fructose, galactose, sodium glutamate, thiamine, alanine, ammonium, uric acid, albumin, glutamine, guanine, troponine T, and glucose, the sensor showed good selectivity for Mb. It demonstrated a good recovery for the detection of Mb in several fake serum samples (93.0–103.3%), with an average relative standard deviation of 4.5%. The current approach might be viewed as a potentially fruitful analytical tool for obtaining disposable, cost-effective paper-based potentiometric sensing devices. These types of analytical devices can be potentially manufacturable at large scales in clinical analysis.
format Online
Article
Text
id pubmed-10193383
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-101933832023-05-19 Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker Almehizia, Abdulrahman A. Naglah, Ahmed M. Alrasheed, Lamees S. Alanazi, Mashael G. Amr, Abdel El-Galil E. Kamel, Ayman H. RSC Adv Chemistry One of the cardiac biomarkers, myoglobin (Mb), is important in the rapid identification of cardio-vascular disorders. Therefore, point-of-care monitoring is essential. Pursuing this goal, a robust, reliable, and affordable paper-based analytical apparatus for potentiometric sensing has been developed and characterized. The molecular imprint technique was used to create a customized biomimetic antibody for myoglobin (Mb) on the surface of carboxylated multiwalled carbon nanotubes (MWCNT–COOH). This was accomplished by attaching Mb to carboxylated MWCNTs' surfaces and then filling the empty spaces through the mild polymerization of acrylamide in N,N-methylenebisacrylamide and ammonium persulphate. The modification of the MWCNTs' surface was verified by SEM and FTIR analysis. A hydrophobic paper substrate coated with fluorinated alkyl silane (CF(3)(CF(2))(7)CH(2)CH(2)SiCl(3), CF(10)) has been coupled with a printed all–solid–state Ag/AgCl reference electrode. The presented sensors showed a linear range of 5.0 × 10(−8) to 1.0 × 10(−4) M with a potentiometric slope of −57.1 ± 0.3 mV decade(−1) (R(2) = 0.9998) and a detection limit of 28 nM at pH 4. Compared to creatinine, sucrose, fructose, galactose, sodium glutamate, thiamine, alanine, ammonium, uric acid, albumin, glutamine, guanine, troponine T, and glucose, the sensor showed good selectivity for Mb. It demonstrated a good recovery for the detection of Mb in several fake serum samples (93.0–103.3%), with an average relative standard deviation of 4.5%. The current approach might be viewed as a potentially fruitful analytical tool for obtaining disposable, cost-effective paper-based potentiometric sensing devices. These types of analytical devices can be potentially manufacturable at large scales in clinical analysis. The Royal Society of Chemistry 2023-05-18 /pmc/articles/PMC10193383/ /pubmed/37213337 http://dx.doi.org/10.1039/d3ra02375c Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Almehizia, Abdulrahman A.
Naglah, Ahmed M.
Alrasheed, Lamees S.
Alanazi, Mashael G.
Amr, Abdel El-Galil E.
Kamel, Ayman H.
Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
title Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
title_full Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
title_fullStr Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
title_full_unstemmed Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
title_short Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
title_sort point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193383/
https://www.ncbi.nlm.nih.gov/pubmed/37213337
http://dx.doi.org/10.1039/d3ra02375c
work_keys_str_mv AT almehiziaabdulrahmana pointofcarepaperbasedanalyticaldeviceforpotentiometricdetectionofmyoglobinasacardiovasculardiseasebiomarker
AT naglahahmedm pointofcarepaperbasedanalyticaldeviceforpotentiometricdetectionofmyoglobinasacardiovasculardiseasebiomarker
AT alrasheedlameess pointofcarepaperbasedanalyticaldeviceforpotentiometricdetectionofmyoglobinasacardiovasculardiseasebiomarker
AT alanazimashaelg pointofcarepaperbasedanalyticaldeviceforpotentiometricdetectionofmyoglobinasacardiovasculardiseasebiomarker
AT amrabdelelgalile pointofcarepaperbasedanalyticaldeviceforpotentiometricdetectionofmyoglobinasacardiovasculardiseasebiomarker
AT kamelaymanh pointofcarepaperbasedanalyticaldeviceforpotentiometricdetectionofmyoglobinasacardiovasculardiseasebiomarker