Cargando…

Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients

BACKGROUND: There is a close relationship between blood pressure levels and the risk of cardiovascular events, strokes, and kidney disease. For many years, the gold standard instrument for blood pressure measurement was a mercury sphygmomanometer and a stethoscope, but this century-old technique of...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdel-Galeel, Ahmed, Fawzy, Nader N., Ali, Wageeh A., Fouad, Doaa A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193777/
https://www.ncbi.nlm.nih.gov/pubmed/37198541
http://dx.doi.org/10.1186/s12872-023-03292-x
_version_ 1785043886150778880
author Abdel-Galeel, Ahmed
Fawzy, Nader N.
Ali, Wageeh A.
Fouad, Doaa A.
author_facet Abdel-Galeel, Ahmed
Fawzy, Nader N.
Ali, Wageeh A.
Fouad, Doaa A.
author_sort Abdel-Galeel, Ahmed
collection PubMed
description BACKGROUND: There is a close relationship between blood pressure levels and the risk of cardiovascular events, strokes, and kidney disease. For many years, the gold standard instrument for blood pressure measurement was a mercury sphygmomanometer and a stethoscope, but this century-old technique of Riva-Rocci/Korotkov is being progressively removed from clinical practice. Central blood pressure is considered better than peripheral blood pressure in predicting cardiovascular events, as it assesses wave reflections and viscoelastic properties of the arterial wall which make systolic and pulse pressures vary from central to peripheral arteries, but mean blood pressure is constant in the conduit arteries. METHODS: The study included 201 patients with primary hypertension (108 patients with chronic kidney disease and 93 patients without kidney disease). All patients underwent blood pressure measurement by OMRON M2 and Mobil-O-Graph devices, kidney function assessment and abdominal ultrasonography. RESULTS: Patients with chronic kidney disease were significantly older (60.02 ± 9.1 vs. 55.33 ± 8.5; P < 0.001), with longer duration of hypertension (7.56 ± 5.9 vs. 6.05 ± 5.8; P = 0.020) in comparison to those without chronic kidney disease. Automated peripheral measurement of systolic blood pressure, diastolic blood pressure and pulse pressure were significantly higher in comparison to central blood pressure. Patients with chronic kidney disease had significantly higher augmentation index (24.06 ± 12.6 vs. 19.02 ± 10.8; P < 0.001) and pulsed wave velocity (8.66 ± 1.5 vs. 8.69 ± 6.8; P = 0.004) in comparison to those without chronic kidney disease. Augmentation index had positive correlation with pulse wave velocity (r = 0.183, P = 0.005). There was negative correlation between both pulse wave velocity and augmentation index and estimated glomerular filtration rate (r = -0.318, P < 0.001), and (r = -0.236, P < 0.001), respectively. Hence, arterial stiffness parameters are good positive test for prediction of chronic kidney disease. CONCLUSION: There is a strong agreement between non-invasive centrally and automated peripherally measured blood pressure in diagnosis of hypertension. But non-invasive central measurements are preferred over automated measurements for early prediction and detection of renal impairment.
format Online
Article
Text
id pubmed-10193777
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101937772023-05-19 Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients Abdel-Galeel, Ahmed Fawzy, Nader N. Ali, Wageeh A. Fouad, Doaa A. BMC Cardiovasc Disord Research BACKGROUND: There is a close relationship between blood pressure levels and the risk of cardiovascular events, strokes, and kidney disease. For many years, the gold standard instrument for blood pressure measurement was a mercury sphygmomanometer and a stethoscope, but this century-old technique of Riva-Rocci/Korotkov is being progressively removed from clinical practice. Central blood pressure is considered better than peripheral blood pressure in predicting cardiovascular events, as it assesses wave reflections and viscoelastic properties of the arterial wall which make systolic and pulse pressures vary from central to peripheral arteries, but mean blood pressure is constant in the conduit arteries. METHODS: The study included 201 patients with primary hypertension (108 patients with chronic kidney disease and 93 patients without kidney disease). All patients underwent blood pressure measurement by OMRON M2 and Mobil-O-Graph devices, kidney function assessment and abdominal ultrasonography. RESULTS: Patients with chronic kidney disease were significantly older (60.02 ± 9.1 vs. 55.33 ± 8.5; P < 0.001), with longer duration of hypertension (7.56 ± 5.9 vs. 6.05 ± 5.8; P = 0.020) in comparison to those without chronic kidney disease. Automated peripheral measurement of systolic blood pressure, diastolic blood pressure and pulse pressure were significantly higher in comparison to central blood pressure. Patients with chronic kidney disease had significantly higher augmentation index (24.06 ± 12.6 vs. 19.02 ± 10.8; P < 0.001) and pulsed wave velocity (8.66 ± 1.5 vs. 8.69 ± 6.8; P = 0.004) in comparison to those without chronic kidney disease. Augmentation index had positive correlation with pulse wave velocity (r = 0.183, P = 0.005). There was negative correlation between both pulse wave velocity and augmentation index and estimated glomerular filtration rate (r = -0.318, P < 0.001), and (r = -0.236, P < 0.001), respectively. Hence, arterial stiffness parameters are good positive test for prediction of chronic kidney disease. CONCLUSION: There is a strong agreement between non-invasive centrally and automated peripherally measured blood pressure in diagnosis of hypertension. But non-invasive central measurements are preferred over automated measurements for early prediction and detection of renal impairment. BioMed Central 2023-05-17 /pmc/articles/PMC10193777/ /pubmed/37198541 http://dx.doi.org/10.1186/s12872-023-03292-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Abdel-Galeel, Ahmed
Fawzy, Nader N.
Ali, Wageeh A.
Fouad, Doaa A.
Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
title Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
title_full Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
title_fullStr Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
title_full_unstemmed Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
title_short Comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
title_sort comparison between central and automated peripheral blood pressure measurement for early detection of kidney dysfunction in hypertensive patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193777/
https://www.ncbi.nlm.nih.gov/pubmed/37198541
http://dx.doi.org/10.1186/s12872-023-03292-x
work_keys_str_mv AT abdelgaleelahmed comparisonbetweencentralandautomatedperipheralbloodpressuremeasurementforearlydetectionofkidneydysfunctioninhypertensivepatients
AT fawzynadern comparisonbetweencentralandautomatedperipheralbloodpressuremeasurementforearlydetectionofkidneydysfunctioninhypertensivepatients
AT aliwageeha comparisonbetweencentralandautomatedperipheralbloodpressuremeasurementforearlydetectionofkidneydysfunctioninhypertensivepatients
AT fouaddoaaa comparisonbetweencentralandautomatedperipheralbloodpressuremeasurementforearlydetectionofkidneydysfunctioninhypertensivepatients