Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code

PURPOSE: Manufacturing of miniaturized high activity iridium-192 ((192)Ir) sources have been made a market preference in modern brachytherapy. Smaller dimensions of the sources are flexible for smaller diameter of the applicators, and it is also suitable for interstitial implants. Presently, cobalt-...

Descripción completa

Detalles Bibliográficos
Autores principales: Gebremariam, Tsige Yhidego, Geraily, Ghazale, Jassim, Hussam Hameed, Gholami, Somayeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10196727/
https://www.ncbi.nlm.nih.gov/pubmed/37215615
http://dx.doi.org/10.5114/jcb.2023.126238
_version_ 1785044408684511232
author Gebremariam, Tsige Yhidego
Geraily, Ghazale
Jassim, Hussam Hameed
Gholami, Somayeh
author_facet Gebremariam, Tsige Yhidego
Geraily, Ghazale
Jassim, Hussam Hameed
Gholami, Somayeh
author_sort Gebremariam, Tsige Yhidego
collection PubMed
description PURPOSE: Manufacturing of miniaturized high activity iridium-192 ((192)Ir) sources have been made a market preference in modern brachytherapy. Smaller dimensions of the sources are flexible for smaller diameter of the applicators, and it is also suitable for interstitial implants. Presently, cobalt-60 ((60)Co) sources have been commercialized as an alternative to (192)Ir sources for high-dose-rate (HDR) brachytherapy, since (60)Co source have an advantage of longer half-life comparing with (192)Ir source. One of them is the HDR (60)Co Flexisource manufactured by Elekta. The purpose of this study was to compare the TG-43 dosimetric parameters of HDR flexi (60)Co and HDR microSelectron (192)Ir sources. MATERIAL AND METHODS: Monte Carlo simulation code of Geant4 (v.11.0) was applied. Following the recommendations of AAPM TG-43 formalism report, Monte Carlo code of HDR flexi (60)Co and HDR microSelectron (192)Ir was validated by calculating radial dose function, anisotropy function, and dose-rate constants in a water phantom. Finally, results of both radionuclide sources were compared. RESULTS: The calculated dose-rate constants per unit air-kerma strength in water medium were 1.108 cGy h(-1)U(-1) for HDR microSelectron (192)Ir, and 1.097 cGy h(-1)U(-1) for HDR flexi (60)Co source, with the percentage uncertainty of 1.1% and 0.2%, respectively. The values of radial dose function for distances above 22 cm for HDR flexi (60)Co source were higher than that of the other source. The anisotropic values sharply increased to the longitudinal sides of HDR flexi (60)Co source, and the rise was comparatively sharper to that of the other source. CONCLUSIONS: The primary photons from the lower-energy HDR microSelectron (192)Ir source have a limited range and are partially attenuated when considering the results of radial and anisotropic dose distribution functions. This implies that a HDR flexi (60)Co radionuclide could be used to treat tumors beyond the source compared with a HDR microSelectron (192)Ir source, despite the fact that (192)Ir has a lower exit dose than HDR flexi (60)Co radionuclide source.
format Online
Article
Text
id pubmed-10196727
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-101967272023-05-20 Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code Gebremariam, Tsige Yhidego Geraily, Ghazale Jassim, Hussam Hameed Gholami, Somayeh J Contemp Brachytherapy Original Paper PURPOSE: Manufacturing of miniaturized high activity iridium-192 ((192)Ir) sources have been made a market preference in modern brachytherapy. Smaller dimensions of the sources are flexible for smaller diameter of the applicators, and it is also suitable for interstitial implants. Presently, cobalt-60 ((60)Co) sources have been commercialized as an alternative to (192)Ir sources for high-dose-rate (HDR) brachytherapy, since (60)Co source have an advantage of longer half-life comparing with (192)Ir source. One of them is the HDR (60)Co Flexisource manufactured by Elekta. The purpose of this study was to compare the TG-43 dosimetric parameters of HDR flexi (60)Co and HDR microSelectron (192)Ir sources. MATERIAL AND METHODS: Monte Carlo simulation code of Geant4 (v.11.0) was applied. Following the recommendations of AAPM TG-43 formalism report, Monte Carlo code of HDR flexi (60)Co and HDR microSelectron (192)Ir was validated by calculating radial dose function, anisotropy function, and dose-rate constants in a water phantom. Finally, results of both radionuclide sources were compared. RESULTS: The calculated dose-rate constants per unit air-kerma strength in water medium were 1.108 cGy h(-1)U(-1) for HDR microSelectron (192)Ir, and 1.097 cGy h(-1)U(-1) for HDR flexi (60)Co source, with the percentage uncertainty of 1.1% and 0.2%, respectively. The values of radial dose function for distances above 22 cm for HDR flexi (60)Co source were higher than that of the other source. The anisotropic values sharply increased to the longitudinal sides of HDR flexi (60)Co source, and the rise was comparatively sharper to that of the other source. CONCLUSIONS: The primary photons from the lower-energy HDR microSelectron (192)Ir source have a limited range and are partially attenuated when considering the results of radial and anisotropic dose distribution functions. This implies that a HDR flexi (60)Co radionuclide could be used to treat tumors beyond the source compared with a HDR microSelectron (192)Ir source, despite the fact that (192)Ir has a lower exit dose than HDR flexi (60)Co radionuclide source. Termedia Publishing House 2023-03-29 2023-04 /pmc/articles/PMC10196727/ /pubmed/37215615 http://dx.doi.org/10.5114/jcb.2023.126238 Text en Copyright © 2023 Termedia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) )
spellingShingle Original Paper
Gebremariam, Tsige Yhidego
Geraily, Ghazale
Jassim, Hussam Hameed
Gholami, Somayeh
Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
title Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
title_full Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
title_fullStr Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
title_full_unstemmed Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
title_short Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
title_sort dosimetric comparison between microselectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using geant4 monte carlo code
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10196727/
https://www.ncbi.nlm.nih.gov/pubmed/37215615
http://dx.doi.org/10.5114/jcb.2023.126238
work_keys_str_mv AT gebremariamtsigeyhidego dosimetriccomparisonbetweenmicroselectroniridium192andflexicobalt60sourcesinhighdoseratebrachytherapyusinggeant4montecarlocode
AT gerailyghazale dosimetriccomparisonbetweenmicroselectroniridium192andflexicobalt60sourcesinhighdoseratebrachytherapyusinggeant4montecarlocode
AT jassimhussamhameed dosimetriccomparisonbetweenmicroselectroniridium192andflexicobalt60sourcesinhighdoseratebrachytherapyusinggeant4montecarlocode
AT gholamisomayeh dosimetriccomparisonbetweenmicroselectroniridium192andflexicobalt60sourcesinhighdoseratebrachytherapyusinggeant4montecarlocode