Cargando…

Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients

BACKGROUND: The research aimed to evaluate the optimal Single-Photon Emission Computed Tomography (SPECT) cut-off value in differentiating condylar growth activeness, to observe 3-dimensional (3D) mandibular growth pattern, and to explore the potential correlation between 3D measurement parameters a...

Descripción completa

Detalles Bibliográficos
Autores principales: Ouyang, Ningjuan, Zhang, Chenglong, Xu, Feng, Chen, Tiantian, Shen, Guofang, Si, Jiawen, Yu, Hongbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197215/
https://www.ncbi.nlm.nih.gov/pubmed/37202798
http://dx.doi.org/10.1186/s13005-023-00365-2
_version_ 1785044503455858688
author Ouyang, Ningjuan
Zhang, Chenglong
Xu, Feng
Chen, Tiantian
Shen, Guofang
Si, Jiawen
Yu, Hongbo
author_facet Ouyang, Ningjuan
Zhang, Chenglong
Xu, Feng
Chen, Tiantian
Shen, Guofang
Si, Jiawen
Yu, Hongbo
author_sort Ouyang, Ningjuan
collection PubMed
description BACKGROUND: The research aimed to evaluate the optimal Single-Photon Emission Computed Tomography (SPECT) cut-off value in differentiating condylar growth activeness, to observe 3-dimensional (3D) mandibular growth pattern, and to explore the potential correlation between 3D measurement parameters and SPECT uptake ratios in Chinese unilateral condylar hyperplasia (UCH) patients. METHODS:  Data of fifty-four Chinese UCH patients were analyzed retrospectively. All patients underwent SPECT within 1 month before or after the first CT examination (CT1); and received a second CT examination at least 12 months later (CT2). Data from CT scans were analyzed by comparing bilateral differences between CT1 and CT2. The sensitivity and specificity of SPECT were calculated by the receiver operating characteristic (ROC) curve. Pearson’s correlation analysis was performed to investigate whether the mandibular growth was correlated with SPECT value. RESULTS: SPECT had a sensitivity of 68.00% and a specificity of 72.41%, with an area under the ROC curve being 0.709. The optimal SPECT cut-off value for evaluating condylar activity has been determined to be 13%. In patients with an active growing condyle, there was a significant increase in Co-Gn and Co-Go, but not in Go-Gn, Go-MF, or MF-Gn. Pearson’s correlation analysis revealed no correlation between 3D measurement parameters and differences in relative condylar uptake ratios. CONCLUSION: SPECT showed good diagnostic performance in UCH with the cut-off value of 13%. For those with an active growing condyle, the mandible grows diagonally and vertically, while the relative condylar uptake ratio was not directly related to mandibular growth.
format Online
Article
Text
id pubmed-10197215
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101972152023-05-20 Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients Ouyang, Ningjuan Zhang, Chenglong Xu, Feng Chen, Tiantian Shen, Guofang Si, Jiawen Yu, Hongbo Head Face Med Research BACKGROUND: The research aimed to evaluate the optimal Single-Photon Emission Computed Tomography (SPECT) cut-off value in differentiating condylar growth activeness, to observe 3-dimensional (3D) mandibular growth pattern, and to explore the potential correlation between 3D measurement parameters and SPECT uptake ratios in Chinese unilateral condylar hyperplasia (UCH) patients. METHODS:  Data of fifty-four Chinese UCH patients were analyzed retrospectively. All patients underwent SPECT within 1 month before or after the first CT examination (CT1); and received a second CT examination at least 12 months later (CT2). Data from CT scans were analyzed by comparing bilateral differences between CT1 and CT2. The sensitivity and specificity of SPECT were calculated by the receiver operating characteristic (ROC) curve. Pearson’s correlation analysis was performed to investigate whether the mandibular growth was correlated with SPECT value. RESULTS: SPECT had a sensitivity of 68.00% and a specificity of 72.41%, with an area under the ROC curve being 0.709. The optimal SPECT cut-off value for evaluating condylar activity has been determined to be 13%. In patients with an active growing condyle, there was a significant increase in Co-Gn and Co-Go, but not in Go-Gn, Go-MF, or MF-Gn. Pearson’s correlation analysis revealed no correlation between 3D measurement parameters and differences in relative condylar uptake ratios. CONCLUSION: SPECT showed good diagnostic performance in UCH with the cut-off value of 13%. For those with an active growing condyle, the mandible grows diagonally and vertically, while the relative condylar uptake ratio was not directly related to mandibular growth. BioMed Central 2023-05-19 /pmc/articles/PMC10197215/ /pubmed/37202798 http://dx.doi.org/10.1186/s13005-023-00365-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Ouyang, Ningjuan
Zhang, Chenglong
Xu, Feng
Chen, Tiantian
Shen, Guofang
Si, Jiawen
Yu, Hongbo
Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients
title Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients
title_full Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients
title_fullStr Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients
title_full_unstemmed Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients
title_short Evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 Chinese unilateral condylar hyperplasia patients
title_sort evaluation of optimal single-photon emission computed tomography reference value and three-dimensional mandibular growth pattern in 54 chinese unilateral condylar hyperplasia patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197215/
https://www.ncbi.nlm.nih.gov/pubmed/37202798
http://dx.doi.org/10.1186/s13005-023-00365-2
work_keys_str_mv AT ouyangningjuan evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients
AT zhangchenglong evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients
AT xufeng evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients
AT chentiantian evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients
AT shenguofang evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients
AT sijiawen evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients
AT yuhongbo evaluationofoptimalsinglephotonemissioncomputedtomographyreferencevalueandthreedimensionalmandibulargrowthpatternin54chineseunilateralcondylarhyperplasiapatients