Cargando…
Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain
BACKGROUND: The objective of the present study was to examine the evolution of the analytical performance specifications (APS) used in External Quality Assurance (EQA) schemes, as well as the efficacy of a category 1 EQA scheme in monitoring the harmonization of clinical laboratory results in Spain....
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197279/ https://www.ncbi.nlm.nih.gov/pubmed/37362553 http://dx.doi.org/10.1515/almed-2020-0008 |
_version_ | 1785044517181718528 |
---|---|
author | Ricós, Carmen Fernández-Calle, Pilar Marqués, Fernando Minchinela, Joana Salas, Ángel Martínez-Bru, Cecília Boned, Beatriz Gómez-Rioja, Rubén Cortés, Marià González-Lao, Elisabet García-Lario, JV Tejedor-Ganduxé, Xavier Bullich, Sandra Ventura, Montse Simón, Margarida Vilaplana, Carlos González-Tarancón, Ricardo Fernández-Fernández, Mª Pilar Ramón-Bauzá, Francisco Corte, Zoraida Llopis, Mª Antonia Díaz-Garzón, Jorge Perich, Carmen |
author_facet | Ricós, Carmen Fernández-Calle, Pilar Marqués, Fernando Minchinela, Joana Salas, Ángel Martínez-Bru, Cecília Boned, Beatriz Gómez-Rioja, Rubén Cortés, Marià González-Lao, Elisabet García-Lario, JV Tejedor-Ganduxé, Xavier Bullich, Sandra Ventura, Montse Simón, Margarida Vilaplana, Carlos González-Tarancón, Ricardo Fernández-Fernández, Mª Pilar Ramón-Bauzá, Francisco Corte, Zoraida Llopis, Mª Antonia Díaz-Garzón, Jorge Perich, Carmen |
author_sort | Ricós, Carmen |
collection | PubMed |
description | BACKGROUND: The objective of the present study was to examine the evolution of the analytical performance specifications (APS) used in External Quality Assurance (EQA) schemes, as well as the efficacy of a category 1 EQA scheme in monitoring the harmonization of clinical laboratory results in Spain. METHODS: A review of the literature on the types of quality specifications used in schemes in other countries and their evolution was performed. In addition, a comparative analysis of the potential impact that different APS from eight countries had on clinical decision-making was made based on three measurands: sodium, thyroid-stimulating hormone (TSH), and activated partial thromboplastin time (aPTT). RESULTS: Harmonization of analytical methods was demonstrated by assessing whether average results deviated from the certified reference value of control materials within the APS derived from biological variation (BV). The APS used in EQA have evolved from state-of-the-art models to BV. Poor clinical decision-making would occur if the results accepted by some APS were applied. CONCLUSIONS: In Spain, only 2 of the 18 measurands studied are considered to be well harmonized. Closer collaboration between laboratories and analytical system providers would be required to resolve discrepancies. |
format | Online Article Text |
id | pubmed-10197279 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | De Gruyter |
record_format | MEDLINE/PubMed |
spelling | pubmed-101972792023-06-23 Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain Ricós, Carmen Fernández-Calle, Pilar Marqués, Fernando Minchinela, Joana Salas, Ángel Martínez-Bru, Cecília Boned, Beatriz Gómez-Rioja, Rubén Cortés, Marià González-Lao, Elisabet García-Lario, JV Tejedor-Ganduxé, Xavier Bullich, Sandra Ventura, Montse Simón, Margarida Vilaplana, Carlos González-Tarancón, Ricardo Fernández-Fernández, Mª Pilar Ramón-Bauzá, Francisco Corte, Zoraida Llopis, Mª Antonia Díaz-Garzón, Jorge Perich, Carmen Adv Lab Med Article BACKGROUND: The objective of the present study was to examine the evolution of the analytical performance specifications (APS) used in External Quality Assurance (EQA) schemes, as well as the efficacy of a category 1 EQA scheme in monitoring the harmonization of clinical laboratory results in Spain. METHODS: A review of the literature on the types of quality specifications used in schemes in other countries and their evolution was performed. In addition, a comparative analysis of the potential impact that different APS from eight countries had on clinical decision-making was made based on three measurands: sodium, thyroid-stimulating hormone (TSH), and activated partial thromboplastin time (aPTT). RESULTS: Harmonization of analytical methods was demonstrated by assessing whether average results deviated from the certified reference value of control materials within the APS derived from biological variation (BV). The APS used in EQA have evolved from state-of-the-art models to BV. Poor clinical decision-making would occur if the results accepted by some APS were applied. CONCLUSIONS: In Spain, only 2 of the 18 measurands studied are considered to be well harmonized. Closer collaboration between laboratories and analytical system providers would be required to resolve discrepancies. De Gruyter 2020-03-19 /pmc/articles/PMC10197279/ /pubmed/37362553 http://dx.doi.org/10.1515/almed-2020-0008 Text en © 2020 Carmen Ricós et al., published by De Gruyter, Berlin/Boston https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 International License. |
spellingShingle | Article Ricós, Carmen Fernández-Calle, Pilar Marqués, Fernando Minchinela, Joana Salas, Ángel Martínez-Bru, Cecília Boned, Beatriz Gómez-Rioja, Rubén Cortés, Marià González-Lao, Elisabet García-Lario, JV Tejedor-Ganduxé, Xavier Bullich, Sandra Ventura, Montse Simón, Margarida Vilaplana, Carlos González-Tarancón, Ricardo Fernández-Fernández, Mª Pilar Ramón-Bauzá, Francisco Corte, Zoraida Llopis, Mª Antonia Díaz-Garzón, Jorge Perich, Carmen Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain |
title | Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain |
title_full | Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain |
title_fullStr | Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain |
title_full_unstemmed | Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain |
title_short | Impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in Spain |
title_sort | impact of implementing a category 1 external quality assurance scheme for monitoring harmonization of clinical laboratories in spain |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197279/ https://www.ncbi.nlm.nih.gov/pubmed/37362553 http://dx.doi.org/10.1515/almed-2020-0008 |
work_keys_str_mv | AT ricoscarmen impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT fernandezcallepilar impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT marquesfernando impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT minchinelajoana impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT salasangel impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT martinezbrucecilia impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT bonedbeatriz impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT gomezriojaruben impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT cortesmaria impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT gonzalezlaoelisabet impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT garcialariojv impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT tejedorganduxexavier impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT bullichsandra impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT venturamontse impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT simonmargarida impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT vilaplanacarlos impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT gonzaleztaranconricardo impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT fernandezfernandezmapilar impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT ramonbauzafrancisco impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT cortezoraida impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT llopismaantonia impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT diazgarzonjorge impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain AT perichcarmen impactofimplementingacategory1externalqualityassuranceschemeformonitoringharmonizationofclinicallaboratoriesinspain |