Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters

OBJECTIVES: Sigma metrics in an invaluable and inexpensive tool used in laboratories to monitor analytical quality of the assays. Alinity ci platform is a relatively recent analytical system launched by Abbott Diagnostics, and as such performance studies on it are few. We have calculated sigma metri...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanani, Fatima Zehra, Haider Kazmi, Adnan, Kaleem, Bushra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197361/
https://www.ncbi.nlm.nih.gov/pubmed/37363324
http://dx.doi.org/10.1515/almed-2021-0001
_version_ 1785044535930257408
author Kanani, Fatima Zehra
Haider Kazmi, Adnan
Kaleem, Bushra
author_facet Kanani, Fatima Zehra
Haider Kazmi, Adnan
Kaleem, Bushra
author_sort Kanani, Fatima Zehra
collection PubMed
description OBJECTIVES: Sigma metrics in an invaluable and inexpensive tool used in laboratories to monitor analytical quality of the assays. Alinity ci platform is a relatively recent analytical system launched by Abbott Diagnostics, and as such performance studies on it are few. We have calculated sigma metrics of 39 clinical chemistry and immunoassay analytes on two Alinity ci systems. METHODS: Sigma metrics were calculated using results of method validation studies. Coefficient of variation (CV) was calculated according to CLSI EP 15 guidelines. Bias was calculated using three different methods i.e., proficiency testing material, alternate method comparison with existent analyzers and linearity experiment. Total allowable error limits were kept similar to or less than the ones used in reference studies. RESULTS: All analytes except blood urea nitrogen (BUN) demonstrated greater than six sigma value across one or more levels and methods. No analyte amongst clinical chemistry and immunoassays was at below three sigma class. Amongst electrolytes, sodium was below three sigma class at two levels by proficiency testing method, although it was above four sigma class by other two methods. Sigma levels obtained were comparable to those reported in previously published studies. CONCLUSIONS: Acceptable sigma metrics were achieved for all clinical chemistry, immunoassays and electrolytes on Alinity ci. Sigma metrics is an objective and well established cost effective tool to tailor internal quality control practices. This study determines sigma metrics for a wide range of high throughput assays. Long term assay performance needs to be monitored.
format Online
Article
Text
id pubmed-10197361
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher De Gruyter
record_format MEDLINE/PubMed
spelling pubmed-101973612023-06-23 Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters Kanani, Fatima Zehra Haider Kazmi, Adnan Kaleem, Bushra Adv Lab Med Article OBJECTIVES: Sigma metrics in an invaluable and inexpensive tool used in laboratories to monitor analytical quality of the assays. Alinity ci platform is a relatively recent analytical system launched by Abbott Diagnostics, and as such performance studies on it are few. We have calculated sigma metrics of 39 clinical chemistry and immunoassay analytes on two Alinity ci systems. METHODS: Sigma metrics were calculated using results of method validation studies. Coefficient of variation (CV) was calculated according to CLSI EP 15 guidelines. Bias was calculated using three different methods i.e., proficiency testing material, alternate method comparison with existent analyzers and linearity experiment. Total allowable error limits were kept similar to or less than the ones used in reference studies. RESULTS: All analytes except blood urea nitrogen (BUN) demonstrated greater than six sigma value across one or more levels and methods. No analyte amongst clinical chemistry and immunoassays was at below three sigma class. Amongst electrolytes, sodium was below three sigma class at two levels by proficiency testing method, although it was above four sigma class by other two methods. Sigma levels obtained were comparable to those reported in previously published studies. CONCLUSIONS: Acceptable sigma metrics were achieved for all clinical chemistry, immunoassays and electrolytes on Alinity ci. Sigma metrics is an objective and well established cost effective tool to tailor internal quality control practices. This study determines sigma metrics for a wide range of high throughput assays. Long term assay performance needs to be monitored. De Gruyter 2021-04-01 /pmc/articles/PMC10197361/ /pubmed/37363324 http://dx.doi.org/10.1515/almed-2021-0001 Text en © 2021 Fatima Zehra Kanani et al., published by De Gruyter, Berlin/Boston https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 International License.
spellingShingle Article
Kanani, Fatima Zehra
Haider Kazmi, Adnan
Kaleem, Bushra
Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
title Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
title_full Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
title_fullStr Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
title_full_unstemmed Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
title_short Sigma metrics of Alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
title_sort sigma metrics of alinity ci system – a study on thirty-nine clinical chemistry and immunoassay parameters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10197361/
https://www.ncbi.nlm.nih.gov/pubmed/37363324
http://dx.doi.org/10.1515/almed-2021-0001
work_keys_str_mv AT kananifatimazehra sigmametricsofalinitycisystemastudyonthirtynineclinicalchemistryandimmunoassayparameters
AT haiderkazmiadnan sigmametricsofalinitycisystemastudyonthirtynineclinicalchemistryandimmunoassayparameters
AT kaleembushra sigmametricsofalinitycisystemastudyonthirtynineclinicalchemistryandimmunoassayparameters