Cargando…

Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve

BACKGROUND: Patient prosthetic mismatch is a serious but avoidable complication of surgical aortic valve replacement (SAVR) complicated by a small aortic annulus. This study aims to compare early and midterm outcomes following aortic valve replacement (AVR) with a mono-leaflet (ML) valve and a bi-le...

Descripción completa

Detalles Bibliográficos
Autores principales: Anakaputhur Rajan, Venkatesa Kumar, Kaskar, Ameya, Selvam, Sendur, Rao, Rahul, Mehra, Siddhant, Kumaran, Thiruthani, Shetty, Varun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Nature Singapore 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10199289/
https://www.ncbi.nlm.nih.gov/pubmed/37359507
http://dx.doi.org/10.1007/s12055-023-01520-9
_version_ 1785044900508598272
author Anakaputhur Rajan, Venkatesa Kumar
Kaskar, Ameya
Selvam, Sendur
Rao, Rahul
Mehra, Siddhant
Kumaran, Thiruthani
Shetty, Varun
author_facet Anakaputhur Rajan, Venkatesa Kumar
Kaskar, Ameya
Selvam, Sendur
Rao, Rahul
Mehra, Siddhant
Kumaran, Thiruthani
Shetty, Varun
author_sort Anakaputhur Rajan, Venkatesa Kumar
collection PubMed
description BACKGROUND: Patient prosthetic mismatch is a serious but avoidable complication of surgical aortic valve replacement (SAVR) complicated by a small aortic annulus. This study aims to compare early and midterm outcomes following aortic valve replacement (AVR) with a mono-leaflet (ML) valve and a bi-leaflet (BL) valve in a small aortic root. METHODS AND SELECTION: From January 1st, 2017 to December 31st, 2019, 98 patients diagnosed with small aortic root underwent isolated aortic valve replacement with either TTK Chitra valve (Mono-leaflet/ ML group) or St. Jude medical valve (Bi-leaflet/ BL group) of size 17/ 19 mm. Echocardiography was analyzed from medical records and telephonic follow-up. RESULTS: Baseline parameters were comparable. The ML group had 42 patients and the BL group had 56 patients. Aortic cross-clamp time, the incidence of severe patient prosthetic mismatch (p = 0.002) and mean, peak pressure gradients were high in the ML group. Duration of ventilation, intensive care unit (ICU) stay, the incidence of stroke, need for intra-aortic balloon pump, permanent pacemaker, dialysis, and left ventricular mass index in echocardiography were comparable between the two groups postoperatively. There was no early mortality in both group. Survival at the end of 5 years was 57 ± 14.4% in the ML group; 91.8 ± 4% in the BL group (p = 0.005). Univariate and multivariate analysis revealed elderly age as a risk factor for mortality. CONCLUSION: We conclude that aortic valve replacement without any root widening procedure, using a small-sized mechanical valve provides acceptable early outcomes. Bi-leaflet mechanical valves provide better hemodynamics and survival percentage.
format Online
Article
Text
id pubmed-10199289
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Nature Singapore
record_format MEDLINE/PubMed
spelling pubmed-101992892023-05-23 Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve Anakaputhur Rajan, Venkatesa Kumar Kaskar, Ameya Selvam, Sendur Rao, Rahul Mehra, Siddhant Kumaran, Thiruthani Shetty, Varun Indian J Thorac Cardiovasc Surg Original Article BACKGROUND: Patient prosthetic mismatch is a serious but avoidable complication of surgical aortic valve replacement (SAVR) complicated by a small aortic annulus. This study aims to compare early and midterm outcomes following aortic valve replacement (AVR) with a mono-leaflet (ML) valve and a bi-leaflet (BL) valve in a small aortic root. METHODS AND SELECTION: From January 1st, 2017 to December 31st, 2019, 98 patients diagnosed with small aortic root underwent isolated aortic valve replacement with either TTK Chitra valve (Mono-leaflet/ ML group) or St. Jude medical valve (Bi-leaflet/ BL group) of size 17/ 19 mm. Echocardiography was analyzed from medical records and telephonic follow-up. RESULTS: Baseline parameters were comparable. The ML group had 42 patients and the BL group had 56 patients. Aortic cross-clamp time, the incidence of severe patient prosthetic mismatch (p = 0.002) and mean, peak pressure gradients were high in the ML group. Duration of ventilation, intensive care unit (ICU) stay, the incidence of stroke, need for intra-aortic balloon pump, permanent pacemaker, dialysis, and left ventricular mass index in echocardiography were comparable between the two groups postoperatively. There was no early mortality in both group. Survival at the end of 5 years was 57 ± 14.4% in the ML group; 91.8 ± 4% in the BL group (p = 0.005). Univariate and multivariate analysis revealed elderly age as a risk factor for mortality. CONCLUSION: We conclude that aortic valve replacement without any root widening procedure, using a small-sized mechanical valve provides acceptable early outcomes. Bi-leaflet mechanical valves provide better hemodynamics and survival percentage. Springer Nature Singapore 2023-05-20 2023-09 /pmc/articles/PMC10199289/ /pubmed/37359507 http://dx.doi.org/10.1007/s12055-023-01520-9 Text en © Indian Association of Cardiovascular-Thoracic Surgeons 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
spellingShingle Original Article
Anakaputhur Rajan, Venkatesa Kumar
Kaskar, Ameya
Selvam, Sendur
Rao, Rahul
Mehra, Siddhant
Kumaran, Thiruthani
Shetty, Varun
Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve
title Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve
title_full Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve
title_fullStr Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve
title_full_unstemmed Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve
title_short Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve
title_sort aortic valve replacement in small aortic root- bi-leaflet mechanical valve is superior to a mono-leaflet mechanical valve
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10199289/
https://www.ncbi.nlm.nih.gov/pubmed/37359507
http://dx.doi.org/10.1007/s12055-023-01520-9
work_keys_str_mv AT anakaputhurrajanvenkatesakumar aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve
AT kaskarameya aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve
AT selvamsendur aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve
AT raorahul aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve
AT mehrasiddhant aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve
AT kumaranthiruthani aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve
AT shettyvarun aorticvalvereplacementinsmallaorticrootbileafletmechanicalvalveissuperiortoamonoleafletmechanicalvalve