Performance evaluation of mesoscopic photoacoustic imaging

Photoacoustic mesoscopy visualises vascular architecture at high-resolution up to ~3 mm depth. Despite promise in preclinical and clinical imaging studies, with applications in oncology and dermatology, the accuracy and precision of photoacoustic mesoscopy is not well established. Here, we evaluate...

Descripción completa

Detalles Bibliográficos
Autores principales: Hacker, Lina, Brown, Emma L., Lefebvre, Thierry L., Sweeney, Paul W., Bohndiek, Sarah E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10199419/
https://www.ncbi.nlm.nih.gov/pubmed/37214427
http://dx.doi.org/10.1016/j.pacs.2023.100505
_version_ 1785044929501724672
author Hacker, Lina
Brown, Emma L.
Lefebvre, Thierry L.
Sweeney, Paul W.
Bohndiek, Sarah E.
author_facet Hacker, Lina
Brown, Emma L.
Lefebvre, Thierry L.
Sweeney, Paul W.
Bohndiek, Sarah E.
author_sort Hacker, Lina
collection PubMed
description Photoacoustic mesoscopy visualises vascular architecture at high-resolution up to ~3 mm depth. Despite promise in preclinical and clinical imaging studies, with applications in oncology and dermatology, the accuracy and precision of photoacoustic mesoscopy is not well established. Here, we evaluate a commercial photoacoustic mesoscopy system for imaging vascular structures. Typical artefact types are first highlighted and limitations due to non-isotropic illumination and detection are evaluated with respect to rotation, angularity, and depth of the target. Then, using tailored phantoms and mouse models, we investigate system precision, showing coefficients of variation (COV) between repeated scans [short term (1 h): COV= 1.2%; long term (25 days): COV= 9.6%], from target repositioning (without: COV=1.2%, with: COV=4.1%), or from varying in vivo user experience (experienced: COV=15.9%, unexperienced: COV=20.2%). Our findings show robustness of the technique, but also underscore general challenges of limited-view photoacoustic systems in accurately imaging vessel-like structures, thereby guiding users when interpreting biologically-relevant information.
format Online
Article
Text
id pubmed-10199419
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-101994192023-05-21 Performance evaluation of mesoscopic photoacoustic imaging Hacker, Lina Brown, Emma L. Lefebvre, Thierry L. Sweeney, Paul W. Bohndiek, Sarah E. Photoacoustics Research Article Photoacoustic mesoscopy visualises vascular architecture at high-resolution up to ~3 mm depth. Despite promise in preclinical and clinical imaging studies, with applications in oncology and dermatology, the accuracy and precision of photoacoustic mesoscopy is not well established. Here, we evaluate a commercial photoacoustic mesoscopy system for imaging vascular structures. Typical artefact types are first highlighted and limitations due to non-isotropic illumination and detection are evaluated with respect to rotation, angularity, and depth of the target. Then, using tailored phantoms and mouse models, we investigate system precision, showing coefficients of variation (COV) between repeated scans [short term (1 h): COV= 1.2%; long term (25 days): COV= 9.6%], from target repositioning (without: COV=1.2%, with: COV=4.1%), or from varying in vivo user experience (experienced: COV=15.9%, unexperienced: COV=20.2%). Our findings show robustness of the technique, but also underscore general challenges of limited-view photoacoustic systems in accurately imaging vessel-like structures, thereby guiding users when interpreting biologically-relevant information. Elsevier 2023-05-06 /pmc/articles/PMC10199419/ /pubmed/37214427 http://dx.doi.org/10.1016/j.pacs.2023.100505 Text en © 2023 The Authors. Published by Elsevier GmbH. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Hacker, Lina
Brown, Emma L.
Lefebvre, Thierry L.
Sweeney, Paul W.
Bohndiek, Sarah E.
Performance evaluation of mesoscopic photoacoustic imaging
title Performance evaluation of mesoscopic photoacoustic imaging
title_full Performance evaluation of mesoscopic photoacoustic imaging
title_fullStr Performance evaluation of mesoscopic photoacoustic imaging
title_full_unstemmed Performance evaluation of mesoscopic photoacoustic imaging
title_short Performance evaluation of mesoscopic photoacoustic imaging
title_sort performance evaluation of mesoscopic photoacoustic imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10199419/
https://www.ncbi.nlm.nih.gov/pubmed/37214427
http://dx.doi.org/10.1016/j.pacs.2023.100505
work_keys_str_mv AT hackerlina performanceevaluationofmesoscopicphotoacousticimaging
AT brownemmal performanceevaluationofmesoscopicphotoacousticimaging
AT lefebvrethierryl performanceevaluationofmesoscopicphotoacousticimaging
AT sweeneypaulw performanceevaluationofmesoscopicphotoacousticimaging
AT bohndieksarahe performanceevaluationofmesoscopicphotoacousticimaging