PURPOSE: Periprosthetic joint infections induced by methicillin-resistant Staphylococcus aureus (MRSA) pose a major socioeconomic burden. Given the fact that MRSA carriers are at high risk for developing periprosthetic infections regardless of the administration of eradication treatment pre-operativ...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsikopoulos, Konstantinos, Meroni, Gabriele, Kaloudis, Panagiotis, Pavlidou, Eleni, Gravalidis, Christoforos, Tsikopoulos, Ioannis, Drago, Lorenzo, Romano, Carlo Luca, Papaioannidou, Paraskevi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10199848/
https://www.ncbi.nlm.nih.gov/pubmed/36976333
http://dx.doi.org/10.1007/s00264-023-05757-2
Descripción
Sumario:PURPOSE: Periprosthetic joint infections induced by methicillin-resistant Staphylococcus aureus (MRSA) pose a major socioeconomic burden. Given the fact that MRSA carriers are at high risk for developing periprosthetic infections regardless of the administration of eradication treatment pre-operatively, the need for developing new prevention modalities is high. METHODS: The antibacterial and antibiofilm properties of vancomycin, Al(2)O(3) nanowires, and TiO(2) nanoparticles were evaluated in vitro using MIC and MBIC assays. MRSA biofilms were grown on titanium disks simulating orthopedic implants, and the infection prevention potential of vancomycin-, Al(2)O(3) nanowire-, and TiO(2) nanoparticle-supplemented Resomer® coating was evaluated against biofilm controls using the XTT reduction proliferation assay. RESULTS: Among the tested modalities, high- and low-dose vancomycin-loaded Resomer® coating yielded the most satisfactory metalwork protection against MRSA (median absorbance was 0.1705; [IQR = 0.1745] vs control absorbance 0.42 [IQR = 0.07]; p = 0.016; biofilm reduction was 100%; and 0.209 [IQR = 0.1295] vs control 0.42 [IQR = 0.07]; p < 0.001; biofilm reduction was 84%, respectively). On the other hand, polymer coating alone did not provide clinically meaningful biofilm growth prevention (median absorbance was 0.2585 [IQR = 0.1235] vs control 0.395 [IQR = 0.218]; p < 0.001; biofilm reduction was 62%). CONCLUSIONS: We advocate that apart from the well-established preventative measures for MRSA carriers, loading implants with bioresorbable Resomer® vancomycin-supplemented coating may decrease the incidence of early post-op surgical site infections with titanium implants. Of note, the payoff between localized toxicity and antibiofilm efficacy should be considered when loading polymers with highly concentrated antimicrobial agents. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00264-023-05757-2.