Cargando…
Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
BACKGROUND: Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic compu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10201147/ https://www.ncbi.nlm.nih.gov/pubmed/37223123 http://dx.doi.org/10.1177/20584601231177404 |
_version_ | 1785045207983587328 |
---|---|
author | Fleiderman Valenzuela, José Gerardo Cirillo Totera, Juan Ignacio Turkieltaub, Diego Herreros Echaurren, Cristóbal Varela Álvarez Lemos, Facundo Lisandro Arriagada Ramos, Felipe Ignacio |
author_facet | Fleiderman Valenzuela, José Gerardo Cirillo Totera, Juan Ignacio Turkieltaub, Diego Herreros Echaurren, Cristóbal Varela Álvarez Lemos, Facundo Lisandro Arriagada Ramos, Felipe Ignacio |
author_sort | Fleiderman Valenzuela, José Gerardo |
collection | PubMed |
description | BACKGROUND: Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic computer-assisted tools have been developed, and one example of them is Surgimap. PURPOSE: To demonstrate that the sagittal balance measurements with Surgimap are equal and more time-efficient than with Agfa-Enterprise. MATERIAL AND METHODS: Retrospective-prospective study. Biased comparative analysis of radiographic measurements performed on two different occasions (96 h interval), between two spine surgeons using Surgimap and two radiologists using the traditional Cobb method (TCM) with the Agfa-Enterprise program in 36 full spine lateral X-ray, determining inter- and intra-observer reliability and the mean time required to obtain the measurements. RESULTS: Measurements with both methods demonstrated an excellent intra-observer correlation (Surgimap: PCC 0.95 [0.85–0.99]; TCM: PCC 0.90 [0.81–0.99]). Inter-observer correlation also demonstrated an excellent relationship (PCC >0.95). Thoracic kyphosis (TK) demonstrated the lowest levels of inter-observer correlation (PCC: 0.75). The average time in seconds with TCM was 154.6, while with the Surgimap it was 41.8 s. CONCLUSION: Surgimap proved to be equally reliable and 3.5 times faster. Therefore, in consistency with the available literature, our results would allow us to promote the use of Surgimap as a clinical diagnostic tool considering precision and efficiency. |
format | Online Article Text |
id | pubmed-10201147 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-102011472023-05-23 Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap) Fleiderman Valenzuela, José Gerardo Cirillo Totera, Juan Ignacio Turkieltaub, Diego Herreros Echaurren, Cristóbal Varela Álvarez Lemos, Facundo Lisandro Arriagada Ramos, Felipe Ignacio Acta Radiol Open Original Article BACKGROUND: Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic computer-assisted tools have been developed, and one example of them is Surgimap. PURPOSE: To demonstrate that the sagittal balance measurements with Surgimap are equal and more time-efficient than with Agfa-Enterprise. MATERIAL AND METHODS: Retrospective-prospective study. Biased comparative analysis of radiographic measurements performed on two different occasions (96 h interval), between two spine surgeons using Surgimap and two radiologists using the traditional Cobb method (TCM) with the Agfa-Enterprise program in 36 full spine lateral X-ray, determining inter- and intra-observer reliability and the mean time required to obtain the measurements. RESULTS: Measurements with both methods demonstrated an excellent intra-observer correlation (Surgimap: PCC 0.95 [0.85–0.99]; TCM: PCC 0.90 [0.81–0.99]). Inter-observer correlation also demonstrated an excellent relationship (PCC >0.95). Thoracic kyphosis (TK) demonstrated the lowest levels of inter-observer correlation (PCC: 0.75). The average time in seconds with TCM was 154.6, while with the Surgimap it was 41.8 s. CONCLUSION: Surgimap proved to be equally reliable and 3.5 times faster. Therefore, in consistency with the available literature, our results would allow us to promote the use of Surgimap as a clinical diagnostic tool considering precision and efficiency. SAGE Publications 2023-05-20 /pmc/articles/PMC10201147/ /pubmed/37223123 http://dx.doi.org/10.1177/20584601231177404 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Fleiderman Valenzuela, José Gerardo Cirillo Totera, Juan Ignacio Turkieltaub, Diego Herreros Echaurren, Cristóbal Varela Álvarez Lemos, Facundo Lisandro Arriagada Ramos, Felipe Ignacio Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap) |
title | Spino-pelvic radiological parameters: Comparison of measurements
obtained by radiologists using the traditional method versus spine surgeons
using a semi-automated software (Surgimap) |
title_full | Spino-pelvic radiological parameters: Comparison of measurements
obtained by radiologists using the traditional method versus spine surgeons
using a semi-automated software (Surgimap) |
title_fullStr | Spino-pelvic radiological parameters: Comparison of measurements
obtained by radiologists using the traditional method versus spine surgeons
using a semi-automated software (Surgimap) |
title_full_unstemmed | Spino-pelvic radiological parameters: Comparison of measurements
obtained by radiologists using the traditional method versus spine surgeons
using a semi-automated software (Surgimap) |
title_short | Spino-pelvic radiological parameters: Comparison of measurements
obtained by radiologists using the traditional method versus spine surgeons
using a semi-automated software (Surgimap) |
title_sort | spino-pelvic radiological parameters: comparison of measurements
obtained by radiologists using the traditional method versus spine surgeons
using a semi-automated software (surgimap) |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10201147/ https://www.ncbi.nlm.nih.gov/pubmed/37223123 http://dx.doi.org/10.1177/20584601231177404 |
work_keys_str_mv | AT fleidermanvalenzuelajosegerardo spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap AT cirillototerajuanignacio spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap AT turkieltaubdiegoherreros spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap AT echaurrencristobalvarela spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap AT alvarezlemosfacundolisandro spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap AT arriagadaramosfelipeignacio spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap |