Cargando…

Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)

BACKGROUND: Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic compu...

Descripción completa

Detalles Bibliográficos
Autores principales: Fleiderman Valenzuela, José Gerardo, Cirillo Totera, Juan Ignacio, Turkieltaub, Diego Herreros, Echaurren, Cristóbal Varela, Álvarez Lemos, Facundo Lisandro, Arriagada Ramos, Felipe Ignacio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10201147/
https://www.ncbi.nlm.nih.gov/pubmed/37223123
http://dx.doi.org/10.1177/20584601231177404
_version_ 1785045207983587328
author Fleiderman Valenzuela, José Gerardo
Cirillo Totera, Juan Ignacio
Turkieltaub, Diego Herreros
Echaurren, Cristóbal Varela
Álvarez Lemos, Facundo Lisandro
Arriagada Ramos, Felipe Ignacio
author_facet Fleiderman Valenzuela, José Gerardo
Cirillo Totera, Juan Ignacio
Turkieltaub, Diego Herreros
Echaurren, Cristóbal Varela
Álvarez Lemos, Facundo Lisandro
Arriagada Ramos, Felipe Ignacio
author_sort Fleiderman Valenzuela, José Gerardo
collection PubMed
description BACKGROUND: Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic computer-assisted tools have been developed, and one example of them is Surgimap. PURPOSE: To demonstrate that the sagittal balance measurements with Surgimap are equal and more time-efficient than with Agfa-Enterprise. MATERIAL AND METHODS: Retrospective-prospective study. Biased comparative analysis of radiographic measurements performed on two different occasions (96 h interval), between two spine surgeons using Surgimap and two radiologists using the traditional Cobb method (TCM) with the Agfa-Enterprise program in 36 full spine lateral X-ray, determining inter- and intra-observer reliability and the mean time required to obtain the measurements. RESULTS: Measurements with both methods demonstrated an excellent intra-observer correlation (Surgimap: PCC 0.95 [0.85–0.99]; TCM: PCC 0.90 [0.81–0.99]). Inter-observer correlation also demonstrated an excellent relationship (PCC >0.95). Thoracic kyphosis (TK) demonstrated the lowest levels of inter-observer correlation (PCC: 0.75). The average time in seconds with TCM was 154.6, while with the Surgimap it was 41.8 s. CONCLUSION: Surgimap proved to be equally reliable and 3.5 times faster. Therefore, in consistency with the available literature, our results would allow us to promote the use of Surgimap as a clinical diagnostic tool considering precision and efficiency.
format Online
Article
Text
id pubmed-10201147
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-102011472023-05-23 Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap) Fleiderman Valenzuela, José Gerardo Cirillo Totera, Juan Ignacio Turkieltaub, Diego Herreros Echaurren, Cristóbal Varela Álvarez Lemos, Facundo Lisandro Arriagada Ramos, Felipe Ignacio Acta Radiol Open Original Article BACKGROUND: Spinopelvic balance measurement is a key point to get an appropriate diagnosis and treatment in a group of spine pathologies; thus, it seems necessary the evaluation of different methods for obtaining the most reliable values. For that reason, different automatic and semi-automatic computer-assisted tools have been developed, and one example of them is Surgimap. PURPOSE: To demonstrate that the sagittal balance measurements with Surgimap are equal and more time-efficient than with Agfa-Enterprise. MATERIAL AND METHODS: Retrospective-prospective study. Biased comparative analysis of radiographic measurements performed on two different occasions (96 h interval), between two spine surgeons using Surgimap and two radiologists using the traditional Cobb method (TCM) with the Agfa-Enterprise program in 36 full spine lateral X-ray, determining inter- and intra-observer reliability and the mean time required to obtain the measurements. RESULTS: Measurements with both methods demonstrated an excellent intra-observer correlation (Surgimap: PCC 0.95 [0.85–0.99]; TCM: PCC 0.90 [0.81–0.99]). Inter-observer correlation also demonstrated an excellent relationship (PCC >0.95). Thoracic kyphosis (TK) demonstrated the lowest levels of inter-observer correlation (PCC: 0.75). The average time in seconds with TCM was 154.6, while with the Surgimap it was 41.8 s. CONCLUSION: Surgimap proved to be equally reliable and 3.5 times faster. Therefore, in consistency with the available literature, our results would allow us to promote the use of Surgimap as a clinical diagnostic tool considering precision and efficiency. SAGE Publications 2023-05-20 /pmc/articles/PMC10201147/ /pubmed/37223123 http://dx.doi.org/10.1177/20584601231177404 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Fleiderman Valenzuela, José Gerardo
Cirillo Totera, Juan Ignacio
Turkieltaub, Diego Herreros
Echaurren, Cristóbal Varela
Álvarez Lemos, Facundo Lisandro
Arriagada Ramos, Felipe Ignacio
Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
title Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
title_full Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
title_fullStr Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
title_full_unstemmed Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
title_short Spino-pelvic radiological parameters: Comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (Surgimap)
title_sort spino-pelvic radiological parameters: comparison of measurements obtained by radiologists using the traditional method versus spine surgeons using a semi-automated software (surgimap)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10201147/
https://www.ncbi.nlm.nih.gov/pubmed/37223123
http://dx.doi.org/10.1177/20584601231177404
work_keys_str_mv AT fleidermanvalenzuelajosegerardo spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap
AT cirillototerajuanignacio spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap
AT turkieltaubdiegoherreros spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap
AT echaurrencristobalvarela spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap
AT alvarezlemosfacundolisandro spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap
AT arriagadaramosfelipeignacio spinopelvicradiologicalparameterscomparisonofmeasurementsobtainedbyradiologistsusingthetraditionalmethodversusspinesurgeonsusingasemiautomatedsoftwaresurgimap