PURPOSE: Variability in practice exists in death determination by circulatory criteria in the context of organ donation. We sought to describe the practices of intensive care health care professionals for death determination by circulatory criteria with and without organ donation. METHODS: This stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Shemie, Jonah, Scales, Nathan B., Sucha, Ewa, Barrowman, Nick, Hornby, Laura, van Beinum, Amanda, Dhanani, Sonny
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10202993/
https://www.ncbi.nlm.nih.gov/pubmed/37131026
http://dx.doi.org/10.1007/s12630-023-02412-7
Descripción
Sumario:PURPOSE: Variability in practice exists in death determination by circulatory criteria in the context of organ donation. We sought to describe the practices of intensive care health care professionals for death determination by circulatory criteria with and without organ donation. METHODS: This study is a retrospective analysis of prospectively collected data. We included patients with death determination by circulatory criteria in intensive care units at 16 hospitals in Canada, three in the Czech Republic, and one in the Netherlands. Results were recorded using a checklist for the determination of death questionnaire. RESULTS: A total of 583 patients had their death determination checklist reviewed for statistical analysis. The mean (standard deviation) age in years was 64 (15). Three hundred and fourteen (54.0%) patients were from Canada, 230 (39.5%) were from the Czech Republic, and 38 (6.5%) were from the Netherlands. Fifty-two (8.9%) patients proceeded with donation after death determination by circulatory criteria (DCD). The most common diagnostic tests reported for the whole group were absent heart sounds by auscultation (81.8%), flat continuous arterial blood pressure (ABP) tracing (77.0%), and flat electrocardiogram tracing (73.2%). In patients who successfully underwent DCD (N = 52), death was determined most frequently using a flat continuous ABP tracing (94%), absent pulse oximetry (85%), and absent palpable pulse (77%). CONCLUSION: In this study, we have described practices for death determination by circulatory criteria both within and between countries. Though some variability exists, we are reassured that appropriate criteria are almost always used in the context of organ donation. In particular, the use of continuous ABP monitoring in DCD was consistent. It highlights the need for standardization of practice and up to date guidelines, especially within the context of DCD where there is both an ethical and a legal requirement to adhere to the dead donor rule, while minimizing time between death determination and organ procurement. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12630-023-02412-7.