Cargando…

Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review

We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is re...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Hongfei, Li, Zhong, Ma, Teng, Ren, Cheng, Xu, Yibo, Huang, Qiang, Zhang, Kun, Li, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10203210/
https://www.ncbi.nlm.nih.gov/pubmed/37228760
http://dx.doi.org/10.3389/fsurg.2023.1170760
_version_ 1785045581877477376
author Qi, Hongfei
Li, Zhong
Ma, Teng
Ren, Cheng
Xu, Yibo
Huang, Qiang
Zhang, Kun
Li, Ming
author_facet Qi, Hongfei
Li, Zhong
Ma, Teng
Ren, Cheng
Xu, Yibo
Huang, Qiang
Zhang, Kun
Li, Ming
author_sort Qi, Hongfei
collection PubMed
description We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is reliable, no additional bone tunnel is required, and the fixation of the lower patellar fracture can be achieved at the same time. After the operation, the patient starts functional exercise of the knee joint at an early stage, The function of the knee joint of the patient recovered well after 1 year, without other complications.
format Online
Article
Text
id pubmed-10203210
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-102032102023-05-24 Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review Qi, Hongfei Li, Zhong Ma, Teng Ren, Cheng Xu, Yibo Huang, Qiang Zhang, Kun Li, Ming Front Surg Surgery We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is reliable, no additional bone tunnel is required, and the fixation of the lower patellar fracture can be achieved at the same time. After the operation, the patient starts functional exercise of the knee joint at an early stage, The function of the knee joint of the patient recovered well after 1 year, without other complications. Frontiers Media S.A. 2023-05-09 /pmc/articles/PMC10203210/ /pubmed/37228760 http://dx.doi.org/10.3389/fsurg.2023.1170760 Text en © 2023 Qi, Li, Ma, Ren, Xu, Huang, Zhang and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Qi, Hongfei
Li, Zhong
Ma, Teng
Ren, Cheng
Xu, Yibo
Huang, Qiang
Zhang, Kun
Li, Ming
Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
title Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
title_full Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
title_fullStr Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
title_full_unstemmed Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
title_short Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
title_sort treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10203210/
https://www.ncbi.nlm.nih.gov/pubmed/37228760
http://dx.doi.org/10.3389/fsurg.2023.1170760
work_keys_str_mv AT qihongfei treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT lizhong treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT mateng treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT rencheng treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT xuyibo treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT huangqiang treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT zhangkun treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview
AT liming treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview