Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review
We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is re...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10203210/ https://www.ncbi.nlm.nih.gov/pubmed/37228760 http://dx.doi.org/10.3389/fsurg.2023.1170760 |
_version_ | 1785045581877477376 |
---|---|
author | Qi, Hongfei Li, Zhong Ma, Teng Ren, Cheng Xu, Yibo Huang, Qiang Zhang, Kun Li, Ming |
author_facet | Qi, Hongfei Li, Zhong Ma, Teng Ren, Cheng Xu, Yibo Huang, Qiang Zhang, Kun Li, Ming |
author_sort | Qi, Hongfei |
collection | PubMed |
description | We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is reliable, no additional bone tunnel is required, and the fixation of the lower patellar fracture can be achieved at the same time. After the operation, the patient starts functional exercise of the knee joint at an early stage, The function of the knee joint of the patient recovered well after 1 year, without other complications. |
format | Online Article Text |
id | pubmed-10203210 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-102032102023-05-24 Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review Qi, Hongfei Li, Zhong Ma, Teng Ren, Cheng Xu, Yibo Huang, Qiang Zhang, Kun Li, Ming Front Surg Surgery We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is reliable, no additional bone tunnel is required, and the fixation of the lower patellar fracture can be achieved at the same time. After the operation, the patient starts functional exercise of the knee joint at an early stage, The function of the knee joint of the patient recovered well after 1 year, without other complications. Frontiers Media S.A. 2023-05-09 /pmc/articles/PMC10203210/ /pubmed/37228760 http://dx.doi.org/10.3389/fsurg.2023.1170760 Text en © 2023 Qi, Li, Ma, Ren, Xu, Huang, Zhang and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Qi, Hongfei Li, Zhong Ma, Teng Ren, Cheng Xu, Yibo Huang, Qiang Zhang, Kun Li, Ming Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
title | Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
title_full | Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
title_fullStr | Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
title_full_unstemmed | Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
title_short | Treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
title_sort | treatment of proximal patellar tendon rupture with custom-made anchor-like plate and suture: cases report and literature review |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10203210/ https://www.ncbi.nlm.nih.gov/pubmed/37228760 http://dx.doi.org/10.3389/fsurg.2023.1170760 |
work_keys_str_mv | AT qihongfei treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT lizhong treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT mateng treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT rencheng treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT xuyibo treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT huangqiang treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT zhangkun treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview AT liming treatmentofproximalpatellartendonrupturewithcustommadeanchorlikeplateandsuturecasesreportandliteraturereview |