Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans

With advancements in technology able to quantify wide-ranging features of human movement, the aim of the present study was to investigate the inter-device technological reliability of a three-dimensional markerless motion capture system (3D-MCS), quantifying different movement tasks. A total of 20 h...

Descripción completa

Detalles Bibliográficos
Autores principales: Philipp, Nicolas M., Cabarkapa, Dimitrije, Cabarkapa, Damjana V., Eserhaut, Drake A., Fry, Andrew C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204374/
https://www.ncbi.nlm.nih.gov/pubmed/37218865
http://dx.doi.org/10.3390/jfmk8020069
_version_ 1785045818840973312
author Philipp, Nicolas M.
Cabarkapa, Dimitrije
Cabarkapa, Damjana V.
Eserhaut, Drake A.
Fry, Andrew C.
author_facet Philipp, Nicolas M.
Cabarkapa, Dimitrije
Cabarkapa, Damjana V.
Eserhaut, Drake A.
Fry, Andrew C.
author_sort Philipp, Nicolas M.
collection PubMed
description With advancements in technology able to quantify wide-ranging features of human movement, the aim of the present study was to investigate the inter-device technological reliability of a three-dimensional markerless motion capture system (3D-MCS), quantifying different movement tasks. A total of 20 healthy individuals performed a test battery consisting of 29 different movements, from which 214 different metrics were derived. Two 3D-MCS located in close proximity were utilized to quantify movement characteristics. Independent sample t-tests with selected reliability statistics (i.e., intraclass correlation coefficient (ICC), effect sizes, and mean absolute differences) were used to evaluate the agreement between the two systems. The study results suggested that 95.7% of all metrics analyzed revealed negligible or small between-device effect sizes. Further, 91.6% of all metrics analyzed showed moderate or better agreement when looking at the ICC values, while 32.2% of all metrics showed excellent agreement. For metrics measuring joint angles (198 metrics), the mean difference between systems was 2.9 degrees, while for metrics investigating distance measures (16 metrics; e.g., center of mass depth), the mean difference between systems was 0.62 cm. Caution is advised when trying to generalize the study findings beyond the specific technology and software used in this investigation. Given the technological reliability reported in this study, as well as the logistical and time-related limitations associated with marker-based motion capture systems, it may be suggested that 3D-MCS present practitioners with an opportunity to reliably and efficiently measure the movement characteristics of patients and athletes. This has implications for monitoring the health/performance of a broad range of populations.
format Online
Article
Text
id pubmed-10204374
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102043742023-05-24 Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans Philipp, Nicolas M. Cabarkapa, Dimitrije Cabarkapa, Damjana V. Eserhaut, Drake A. Fry, Andrew C. J Funct Morphol Kinesiol Article With advancements in technology able to quantify wide-ranging features of human movement, the aim of the present study was to investigate the inter-device technological reliability of a three-dimensional markerless motion capture system (3D-MCS), quantifying different movement tasks. A total of 20 healthy individuals performed a test battery consisting of 29 different movements, from which 214 different metrics were derived. Two 3D-MCS located in close proximity were utilized to quantify movement characteristics. Independent sample t-tests with selected reliability statistics (i.e., intraclass correlation coefficient (ICC), effect sizes, and mean absolute differences) were used to evaluate the agreement between the two systems. The study results suggested that 95.7% of all metrics analyzed revealed negligible or small between-device effect sizes. Further, 91.6% of all metrics analyzed showed moderate or better agreement when looking at the ICC values, while 32.2% of all metrics showed excellent agreement. For metrics measuring joint angles (198 metrics), the mean difference between systems was 2.9 degrees, while for metrics investigating distance measures (16 metrics; e.g., center of mass depth), the mean difference between systems was 0.62 cm. Caution is advised when trying to generalize the study findings beyond the specific technology and software used in this investigation. Given the technological reliability reported in this study, as well as the logistical and time-related limitations associated with marker-based motion capture systems, it may be suggested that 3D-MCS present practitioners with an opportunity to reliably and efficiently measure the movement characteristics of patients and athletes. This has implications for monitoring the health/performance of a broad range of populations. MDPI 2023-05-22 /pmc/articles/PMC10204374/ /pubmed/37218865 http://dx.doi.org/10.3390/jfmk8020069 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Philipp, Nicolas M.
Cabarkapa, Dimitrije
Cabarkapa, Damjana V.
Eserhaut, Drake A.
Fry, Andrew C.
Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
title Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
title_full Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
title_fullStr Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
title_full_unstemmed Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
title_short Inter-Device Reliability of a Three-Dimensional Markerless Motion Capture System Quantifying Elementary Movement Patterns in Humans
title_sort inter-device reliability of a three-dimensional markerless motion capture system quantifying elementary movement patterns in humans
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204374/
https://www.ncbi.nlm.nih.gov/pubmed/37218865
http://dx.doi.org/10.3390/jfmk8020069
work_keys_str_mv AT philippnicolasm interdevicereliabilityofathreedimensionalmarkerlessmotioncapturesystemquantifyingelementarymovementpatternsinhumans
AT cabarkapadimitrije interdevicereliabilityofathreedimensionalmarkerlessmotioncapturesystemquantifyingelementarymovementpatternsinhumans
AT cabarkapadamjanav interdevicereliabilityofathreedimensionalmarkerlessmotioncapturesystemquantifyingelementarymovementpatternsinhumans
AT eserhautdrakea interdevicereliabilityofathreedimensionalmarkerlessmotioncapturesystemquantifyingelementarymovementpatternsinhumans
AT fryandrewc interdevicereliabilityofathreedimensionalmarkerlessmotioncapturesystemquantifyingelementarymovementpatternsinhumans