Cargando…

Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study

The reliability of isokinetic peak torque (PT) has been reported mostly using a short-term (<~10 day) inter-trial testing time frame. However, many studies and programs utilize a long-term (several weeks to months) inter-trial testing period. Additionally, the methods by which the PT value is sel...

Descripción completa

Detalles Bibliográficos
Autores principales: Thompson, Brennan J., Xu, Jennifer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204485/
https://www.ncbi.nlm.nih.gov/pubmed/37218858
http://dx.doi.org/10.3390/jfmk8020062
_version_ 1785045845130870784
author Thompson, Brennan J.
Xu, Jennifer
author_facet Thompson, Brennan J.
Xu, Jennifer
author_sort Thompson, Brennan J.
collection PubMed
description The reliability of isokinetic peak torque (PT) has been reported mostly using a short-term (<~10 day) inter-trial testing time frame. However, many studies and programs utilize a long-term (several weeks to months) inter-trial testing period. Additionally, the methods by which the PT value is selected and reported from a multiple rep testing scheme have not been well investigated for both reliability and PT absolute performance comparisons. The purpose of this study was to investigate the long-term reliability of isokinetic and isometric PT of the leg extensors with an emphasis on the differences among several PT score selection methods. Thirteen men and women (age = 19.5 years) underwent two testing trials separated by 28.8 (±1.8) days. Testing included maximal voluntary contractions of three sets of three reps for two isokinetic contraction conditions of 60 (Isok60) and 240 (Isok240) deg/s velocities, and three sets of one rep of isometric contractions for the leg extensors. The PT score was derived from seven different methods (see text for descriptions). Reliability as assessed from intraclass correlation coefficients (ICCs) varied widely across contraction conditions and PT score selection parameters. The Isok60 velocity overall had lower reliability (ICCs = 0.48–0.81) than Isok240 (0.77–0.87) across the conditions whereas the isometric PT variables showed moderate reliability (0.71–0.73). Overall the set 1 PT score selection parameters were generally lower (p ≤ 0.05) than those that involved sets two and three. Systematic error (p ≤ 0.05) was shown for 6 out of the 17 PT selection variables. On a subjective interpretation basis, when taking everything into account the best overall combination of time/trial efficiency, reliability, best/highest PT score parameter, and reduced risk of systematic bias appears to be the PT variable that uses the average of the highest two reps of the first two sets of three reps—i.e., averaging the highest two values of the six total reps from the first two sets.
format Online
Article
Text
id pubmed-10204485
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102044852023-05-24 Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study Thompson, Brennan J. Xu, Jennifer J Funct Morphol Kinesiol Article The reliability of isokinetic peak torque (PT) has been reported mostly using a short-term (<~10 day) inter-trial testing time frame. However, many studies and programs utilize a long-term (several weeks to months) inter-trial testing period. Additionally, the methods by which the PT value is selected and reported from a multiple rep testing scheme have not been well investigated for both reliability and PT absolute performance comparisons. The purpose of this study was to investigate the long-term reliability of isokinetic and isometric PT of the leg extensors with an emphasis on the differences among several PT score selection methods. Thirteen men and women (age = 19.5 years) underwent two testing trials separated by 28.8 (±1.8) days. Testing included maximal voluntary contractions of three sets of three reps for two isokinetic contraction conditions of 60 (Isok60) and 240 (Isok240) deg/s velocities, and three sets of one rep of isometric contractions for the leg extensors. The PT score was derived from seven different methods (see text for descriptions). Reliability as assessed from intraclass correlation coefficients (ICCs) varied widely across contraction conditions and PT score selection parameters. The Isok60 velocity overall had lower reliability (ICCs = 0.48–0.81) than Isok240 (0.77–0.87) across the conditions whereas the isometric PT variables showed moderate reliability (0.71–0.73). Overall the set 1 PT score selection parameters were generally lower (p ≤ 0.05) than those that involved sets two and three. Systematic error (p ≤ 0.05) was shown for 6 out of the 17 PT selection variables. On a subjective interpretation basis, when taking everything into account the best overall combination of time/trial efficiency, reliability, best/highest PT score parameter, and reduced risk of systematic bias appears to be the PT variable that uses the average of the highest two reps of the first two sets of three reps—i.e., averaging the highest two values of the six total reps from the first two sets. MDPI 2023-05-12 /pmc/articles/PMC10204485/ /pubmed/37218858 http://dx.doi.org/10.3390/jfmk8020062 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Thompson, Brennan J.
Xu, Jennifer
Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
title Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
title_full Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
title_fullStr Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
title_full_unstemmed Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
title_short Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
title_sort isokinetic dynamometer leg extensor peak torque measurement: a time-delayed reliability and score selection analysis study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204485/
https://www.ncbi.nlm.nih.gov/pubmed/37218858
http://dx.doi.org/10.3390/jfmk8020062
work_keys_str_mv AT thompsonbrennanj isokineticdynamometerlegextensorpeaktorquemeasurementatimedelayedreliabilityandscoreselectionanalysisstudy
AT xujennifer isokineticdynamometerlegextensorpeaktorquemeasurementatimedelayedreliabilityandscoreselectionanalysisstudy