Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs
Rapid diagnosis or exclusion of SARS-CoV-2 infection is essential for correct medical management decisions regarding COVID-19. High-throughput laboratory-based reverse transcriptase (RT)-PCR testing is accurate with longer turnaround times, while rapid antigen tests show moderate sensitivity. In sea...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204629/ https://www.ncbi.nlm.nih.gov/pubmed/37093001 http://dx.doi.org/10.1128/jcm.01871-22 |
_version_ | 1785045874111414272 |
---|---|
author | Bos, David A. G. Lagrou, Katrien Verbakel, Jan Y. |
author_facet | Bos, David A. G. Lagrou, Katrien Verbakel, Jan Y. |
author_sort | Bos, David A. G. |
collection | PubMed |
description | Rapid diagnosis or exclusion of SARS-CoV-2 infection is essential for correct medical management decisions regarding COVID-19. High-throughput laboratory-based reverse transcriptase (RT)-PCR testing is accurate with longer turnaround times, while rapid antigen tests show moderate sensitivity. In search of a fast and reliable COVID-19 test, we aimed to validate the rapid miDiagnostics COVID-19 PCR test. We recruited symptomatic and asymptomatic participants in a mobile COVID-19 test center in Belgium. We collected three nasopharyngeal samples from each participant. The index sample was tested on the miDiagnostics COVID-19 PCR reader, the reference sample was tested on the reference TaqPath COVID-19 PCR test in the Belgian Reference Center for Respiratory Pathogens of University Hospitals Leuven, and a third sample was collected for discordance testing with the PerkinElmer SARS-CoV-2 PCR kit. A total of 770 participants yielded 763 sets of included nasopharyngeal samples. Overall positive percent agreement and negative percent agreement of the miDiagnostics COVID-19 PCR test were 95.5% (92.6% to 97.4%) and 94.9% (92.3 to 96.8%), rising to 98.6% (96.5% to 99.6%) and 96.5% (92.6% to 98.7%) in symptomatic patients. Discordance testing reclassified 15 of 21 false-positive cases as true positive. A retest of the miDiagnostics PCR test was performed in 61 tests (7.4%) due to a technical error. The miDiagnostics COVID-19 PCR test showed excellent clinical accuracy. The fast and reliable results allow for rapid correct diagnosis and tailored medical management decisions regarding COVID-19. |
format | Online Article Text |
id | pubmed-10204629 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Society for Microbiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-102046292023-05-24 Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs Bos, David A. G. Lagrou, Katrien Verbakel, Jan Y. J Clin Microbiol Virology Rapid diagnosis or exclusion of SARS-CoV-2 infection is essential for correct medical management decisions regarding COVID-19. High-throughput laboratory-based reverse transcriptase (RT)-PCR testing is accurate with longer turnaround times, while rapid antigen tests show moderate sensitivity. In search of a fast and reliable COVID-19 test, we aimed to validate the rapid miDiagnostics COVID-19 PCR test. We recruited symptomatic and asymptomatic participants in a mobile COVID-19 test center in Belgium. We collected three nasopharyngeal samples from each participant. The index sample was tested on the miDiagnostics COVID-19 PCR reader, the reference sample was tested on the reference TaqPath COVID-19 PCR test in the Belgian Reference Center for Respiratory Pathogens of University Hospitals Leuven, and a third sample was collected for discordance testing with the PerkinElmer SARS-CoV-2 PCR kit. A total of 770 participants yielded 763 sets of included nasopharyngeal samples. Overall positive percent agreement and negative percent agreement of the miDiagnostics COVID-19 PCR test were 95.5% (92.6% to 97.4%) and 94.9% (92.3 to 96.8%), rising to 98.6% (96.5% to 99.6%) and 96.5% (92.6% to 98.7%) in symptomatic patients. Discordance testing reclassified 15 of 21 false-positive cases as true positive. A retest of the miDiagnostics PCR test was performed in 61 tests (7.4%) due to a technical error. The miDiagnostics COVID-19 PCR test showed excellent clinical accuracy. The fast and reliable results allow for rapid correct diagnosis and tailored medical management decisions regarding COVID-19. American Society for Microbiology 2023-04-24 /pmc/articles/PMC10204629/ /pubmed/37093001 http://dx.doi.org/10.1128/jcm.01871-22 Text en Copyright © 2023 American Society for Microbiology. https://doi.org/10.1128/ASMCopyrightv2All Rights Reserved (https://doi.org/10.1128/ASMCopyrightv2) . https://doi.org/10.1128/ASMCopyrightv2This article is made available via the PMC Open Access Subset for unrestricted noncommercial re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Virology Bos, David A. G. Lagrou, Katrien Verbakel, Jan Y. Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs |
title | Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs |
title_full | Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs |
title_fullStr | Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs |
title_full_unstemmed | Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs |
title_short | Prospective Performance Evaluation of the miDiagnostics COVID-19 PCR Test for Rapid SARS-CoV-2 Detection on Nasopharyngeal Swabs |
title_sort | prospective performance evaluation of the midiagnostics covid-19 pcr test for rapid sars-cov-2 detection on nasopharyngeal swabs |
topic | Virology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204629/ https://www.ncbi.nlm.nih.gov/pubmed/37093001 http://dx.doi.org/10.1128/jcm.01871-22 |
work_keys_str_mv | AT bosdavidag prospectiveperformanceevaluationofthemidiagnosticscovid19pcrtestforrapidsarscov2detectiononnasopharyngealswabs AT lagroukatrien prospectiveperformanceevaluationofthemidiagnosticscovid19pcrtestforrapidsarscov2detectiononnasopharyngealswabs AT verbakeljany prospectiveperformanceevaluationofthemidiagnosticscovid19pcrtestforrapidsarscov2detectiononnasopharyngealswabs |