Cargando…

Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma

BACKGROUND: Glaucoma is the leading cause of global irreversible blindness. The goal of management in glaucoma lies in its early detection and treatment to prevent further optic neuropathy. Available equipment for early glaucoma detection is not cost-effective or readily available in resource-scarce...

Descripción completa

Detalles Bibliográficos
Autores principales: Gbadegesin, Temitope Mariam, Olawoye, Olusola, Sarimiye, Tarela Frederick, Idowu, Oluwatobi Olalekan, Ajayi, Benedictus G.K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204916/
https://www.ncbi.nlm.nih.gov/pubmed/37228887
http://dx.doi.org/10.4103/jwas.jwas_275_22
_version_ 1785045930664263680
author Gbadegesin, Temitope Mariam
Olawoye, Olusola
Sarimiye, Tarela Frederick
Idowu, Oluwatobi Olalekan
Ajayi, Benedictus G.K.
author_facet Gbadegesin, Temitope Mariam
Olawoye, Olusola
Sarimiye, Tarela Frederick
Idowu, Oluwatobi Olalekan
Ajayi, Benedictus G.K.
author_sort Gbadegesin, Temitope Mariam
collection PubMed
description BACKGROUND: Glaucoma is the leading cause of global irreversible blindness. The goal of management in glaucoma lies in its early detection and treatment to prevent further optic neuropathy. Available equipment for early glaucoma detection is not cost-effective or readily available in resource-scarce settings such as Nigeria. Thus, there is a need for a simple cost-effective tool to detect glaucomatous central visual field (CVF) defects in all the stages of glaucoma within the community in resource scarce-settings. AIMS AND OBJECTIVES: The aim of this article is to determine the validity of the Amsler grid in detecting central glaucomatous visual field defects in primary open angle glaucoma (POAG). MATERIALS AND METHODS: This was a cross-sectional study of follow-up glaucoma patients at a secondary eye care hospital in Nigeria. All patients had detailed ophthalmic examination in addition to 24-2 and 10-2 CVF tests and Amsler grid test. POAG was classified using the Hodapp–Parrish–Anderson criteria into mild, moderate, and severe on 24-2 CVF. The diagnostic validity of the Amsler grid was calculated using the 10-2 CVF as a reference standard. Regression analyses were performed between the Amsler grid scotoma area and 10-2 CVF parameters [mean deviation (MD), scotoma extent (SE), and scotoma mean depth (SMD)]. RESULTS: A total of 150 eyes of 150 patients were enrolled. The sensitivity, specificity, and positive predictive value and negative predictive value of the Amsler grid compared with the 10-2 CVF was 49.5%, 95.9%, 96.2%, and 47.9%, respectively, with an area under curve of 0.7. Sensitivity increased with increasing severity (P < 0.001) from 20.0%, 31.0%, and 76.6% in mild, moderate, and severe POAG, respectively. The Amsler grid scotoma area had the strongest relationship with the 10-2 MD, followed by 10-2 SE and 10-2 SMD with a quadratic R(2) of 0.579, 0.370, and 0.307, respectively. CONCLUSION: The Amsler grid has a low sensitivity in mild-to-moderate POAG. However, it may serve as an adjunctive tool in resource-scarce settings for detection of severe POAG in the community by primary eye care providers.
format Online
Article
Text
id pubmed-10204916
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-102049162023-05-24 Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma Gbadegesin, Temitope Mariam Olawoye, Olusola Sarimiye, Tarela Frederick Idowu, Oluwatobi Olalekan Ajayi, Benedictus G.K. J West Afr Coll Surg Original Article BACKGROUND: Glaucoma is the leading cause of global irreversible blindness. The goal of management in glaucoma lies in its early detection and treatment to prevent further optic neuropathy. Available equipment for early glaucoma detection is not cost-effective or readily available in resource-scarce settings such as Nigeria. Thus, there is a need for a simple cost-effective tool to detect glaucomatous central visual field (CVF) defects in all the stages of glaucoma within the community in resource scarce-settings. AIMS AND OBJECTIVES: The aim of this article is to determine the validity of the Amsler grid in detecting central glaucomatous visual field defects in primary open angle glaucoma (POAG). MATERIALS AND METHODS: This was a cross-sectional study of follow-up glaucoma patients at a secondary eye care hospital in Nigeria. All patients had detailed ophthalmic examination in addition to 24-2 and 10-2 CVF tests and Amsler grid test. POAG was classified using the Hodapp–Parrish–Anderson criteria into mild, moderate, and severe on 24-2 CVF. The diagnostic validity of the Amsler grid was calculated using the 10-2 CVF as a reference standard. Regression analyses were performed between the Amsler grid scotoma area and 10-2 CVF parameters [mean deviation (MD), scotoma extent (SE), and scotoma mean depth (SMD)]. RESULTS: A total of 150 eyes of 150 patients were enrolled. The sensitivity, specificity, and positive predictive value and negative predictive value of the Amsler grid compared with the 10-2 CVF was 49.5%, 95.9%, 96.2%, and 47.9%, respectively, with an area under curve of 0.7. Sensitivity increased with increasing severity (P < 0.001) from 20.0%, 31.0%, and 76.6% in mild, moderate, and severe POAG, respectively. The Amsler grid scotoma area had the strongest relationship with the 10-2 MD, followed by 10-2 SE and 10-2 SMD with a quadratic R(2) of 0.579, 0.370, and 0.307, respectively. CONCLUSION: The Amsler grid has a low sensitivity in mild-to-moderate POAG. However, it may serve as an adjunctive tool in resource-scarce settings for detection of severe POAG in the community by primary eye care providers. Wolters Kluwer - Medknow 2023 2023-03-20 /pmc/articles/PMC10204916/ /pubmed/37228887 http://dx.doi.org/10.4103/jwas.jwas_275_22 Text en Copyright: © 2023 Journal of the West African College of Surgeons https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Gbadegesin, Temitope Mariam
Olawoye, Olusola
Sarimiye, Tarela Frederick
Idowu, Oluwatobi Olalekan
Ajayi, Benedictus G.K.
Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma
title Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma
title_full Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma
title_fullStr Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma
title_full_unstemmed Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma
title_short Amsler Grid Versus 10-2 Test in Primary Open Angle Glaucoma
title_sort amsler grid versus 10-2 test in primary open angle glaucoma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10204916/
https://www.ncbi.nlm.nih.gov/pubmed/37228887
http://dx.doi.org/10.4103/jwas.jwas_275_22
work_keys_str_mv AT gbadegesintemitopemariam amslergridversus102testinprimaryopenangleglaucoma
AT olawoyeolusola amslergridversus102testinprimaryopenangleglaucoma
AT sarimiyetarelafrederick amslergridversus102testinprimaryopenangleglaucoma
AT idowuoluwatobiolalekan amslergridversus102testinprimaryopenangleglaucoma
AT ajayibenedictusgk amslergridversus102testinprimaryopenangleglaucoma