Cargando…
Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. MATERIALS AND METHODS: Patients...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10205352/ https://www.ncbi.nlm.nih.gov/pubmed/37228979 http://dx.doi.org/10.1097/MS9.0000000000000601 |
_version_ | 1785046021103943680 |
---|---|
author | Pham, Thao Thi Thanh Kirkpatrick, James N. Duong, Hung Duc Pham, Hung Manh Vu, Thom Thi Giap, Nguyet Thi Minh Trinh, Ha Viet Nguyen, Yen Thi Hai Hoang, Mai Thi Ngoc Nguyen, Hoai Thi Thu |
author_facet | Pham, Thao Thi Thanh Kirkpatrick, James N. Duong, Hung Duc Pham, Hung Manh Vu, Thom Thi Giap, Nguyet Thi Minh Trinh, Ha Viet Nguyen, Yen Thi Hai Hoang, Mai Thi Ngoc Nguyen, Hoai Thi Thu |
author_sort | Pham, Thao Thi Thanh |
collection | PubMed |
description | The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. MATERIALS AND METHODS: Patients with suspected LMVO on transthoracic echocardiography were enrolled consecutively. All patients underwent two-dimensional and three-dimensional TEE, and open-heart surgery to replace obstructed valves. Macroscopic and microscopic analysis of the excised masses was used as the gold standard for the diagnosis of thrombus and/or pannus. RESULTS: Forty-eight patients [34 women (70.8%), age 49±13 years, New York Heart Association II: 68.8%, New York Heart Association III: 31.2%] were enrolled. In the diagnostic of thrombus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 89.2, 72.7, 85.4, 91.7, and 66.7%, respectively, compared with those of two-dimensional TEE (42.2, 66.7, 43.8, 95, and 7.1%, respectively). In the diagnosis of pannus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 53.3, 100, 85.4, 100, and 82.5%, respectively; compared with those of two-dimensional TEE (7.4, 90.5, 43.8, 50, and 43.2%, respectively). Receiver operating characteristic curves depict that the area under the curves of three-dimensional TEE was higher than the area under the curves of two-dimensional TEE in both diagnoses of thrombus and pannus (0.8560 vs. 0.7330, P=0.0427 and 0.8077 vs. 0.5484, P=0.005, respectively). CONCLUSIONS: This study indicated that three-dimensional TEE had a higher diagnostic value than two-dimensional TEE in the detection of thrombus and pannus in patients with LMVO, and can be a reliable imaging modality to identify the causes of LMVO. |
format | Online Article Text |
id | pubmed-10205352 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-102053522023-05-24 Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction Pham, Thao Thi Thanh Kirkpatrick, James N. Duong, Hung Duc Pham, Hung Manh Vu, Thom Thi Giap, Nguyet Thi Minh Trinh, Ha Viet Nguyen, Yen Thi Hai Hoang, Mai Thi Ngoc Nguyen, Hoai Thi Thu Ann Med Surg (Lond) Original Research The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. MATERIALS AND METHODS: Patients with suspected LMVO on transthoracic echocardiography were enrolled consecutively. All patients underwent two-dimensional and three-dimensional TEE, and open-heart surgery to replace obstructed valves. Macroscopic and microscopic analysis of the excised masses was used as the gold standard for the diagnosis of thrombus and/or pannus. RESULTS: Forty-eight patients [34 women (70.8%), age 49±13 years, New York Heart Association II: 68.8%, New York Heart Association III: 31.2%] were enrolled. In the diagnostic of thrombus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 89.2, 72.7, 85.4, 91.7, and 66.7%, respectively, compared with those of two-dimensional TEE (42.2, 66.7, 43.8, 95, and 7.1%, respectively). In the diagnosis of pannus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 53.3, 100, 85.4, 100, and 82.5%, respectively; compared with those of two-dimensional TEE (7.4, 90.5, 43.8, 50, and 43.2%, respectively). Receiver operating characteristic curves depict that the area under the curves of three-dimensional TEE was higher than the area under the curves of two-dimensional TEE in both diagnoses of thrombus and pannus (0.8560 vs. 0.7330, P=0.0427 and 0.8077 vs. 0.5484, P=0.005, respectively). CONCLUSIONS: This study indicated that three-dimensional TEE had a higher diagnostic value than two-dimensional TEE in the detection of thrombus and pannus in patients with LMVO, and can be a reliable imaging modality to identify the causes of LMVO. Lippincott Williams & Wilkins 2023-04-11 /pmc/articles/PMC10205352/ /pubmed/37228979 http://dx.doi.org/10.1097/MS9.0000000000000601 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Research Pham, Thao Thi Thanh Kirkpatrick, James N. Duong, Hung Duc Pham, Hung Manh Vu, Thom Thi Giap, Nguyet Thi Minh Trinh, Ha Viet Nguyen, Yen Thi Hai Hoang, Mai Thi Ngoc Nguyen, Hoai Thi Thu Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
title | Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
title_full | Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
title_fullStr | Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
title_full_unstemmed | Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
title_short | Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
title_sort | diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10205352/ https://www.ncbi.nlm.nih.gov/pubmed/37228979 http://dx.doi.org/10.1097/MS9.0000000000000601 |
work_keys_str_mv | AT phamthaothithanh diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT kirkpatrickjamesn diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT duonghungduc diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT phamhungmanh diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT vuthomthi diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT giapnguyetthiminh diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT trinhhaviet diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT nguyenyenthihai diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT hoangmaithingoc diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction AT nguyenhoaithithu diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction |