Cargando…

Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction

The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. MATERIALS AND METHODS: Patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Pham, Thao Thi Thanh, Kirkpatrick, James N., Duong, Hung Duc, Pham, Hung Manh, Vu, Thom Thi, Giap, Nguyet Thi Minh, Trinh, Ha Viet, Nguyen, Yen Thi Hai, Hoang, Mai Thi Ngoc, Nguyen, Hoai Thi Thu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10205352/
https://www.ncbi.nlm.nih.gov/pubmed/37228979
http://dx.doi.org/10.1097/MS9.0000000000000601
_version_ 1785046021103943680
author Pham, Thao Thi Thanh
Kirkpatrick, James N.
Duong, Hung Duc
Pham, Hung Manh
Vu, Thom Thi
Giap, Nguyet Thi Minh
Trinh, Ha Viet
Nguyen, Yen Thi Hai
Hoang, Mai Thi Ngoc
Nguyen, Hoai Thi Thu
author_facet Pham, Thao Thi Thanh
Kirkpatrick, James N.
Duong, Hung Duc
Pham, Hung Manh
Vu, Thom Thi
Giap, Nguyet Thi Minh
Trinh, Ha Viet
Nguyen, Yen Thi Hai
Hoang, Mai Thi Ngoc
Nguyen, Hoai Thi Thu
author_sort Pham, Thao Thi Thanh
collection PubMed
description The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. MATERIALS AND METHODS: Patients with suspected LMVO on transthoracic echocardiography were enrolled consecutively. All patients underwent two-dimensional and three-dimensional TEE, and open-heart surgery to replace obstructed valves. Macroscopic and microscopic analysis of the excised masses was used as the gold standard for the diagnosis of thrombus and/or pannus. RESULTS: Forty-eight patients [34 women (70.8%), age 49±13 years, New York Heart Association II: 68.8%, New York Heart Association III: 31.2%] were enrolled. In the diagnostic of thrombus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 89.2, 72.7, 85.4, 91.7, and 66.7%, respectively, compared with those of two-dimensional TEE (42.2, 66.7, 43.8, 95, and 7.1%, respectively). In the diagnosis of pannus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 53.3, 100, 85.4, 100, and 82.5%, respectively; compared with those of two-dimensional TEE (7.4, 90.5, 43.8, 50, and 43.2%, respectively). Receiver operating characteristic curves depict that the area under the curves of three-dimensional TEE was higher than the area under the curves of two-dimensional TEE in both diagnoses of thrombus and pannus (0.8560 vs. 0.7330, P=0.0427 and 0.8077 vs. 0.5484, P=0.005, respectively). CONCLUSIONS: This study indicated that three-dimensional TEE had a higher diagnostic value than two-dimensional TEE in the detection of thrombus and pannus in patients with LMVO, and can be a reliable imaging modality to identify the causes of LMVO.
format Online
Article
Text
id pubmed-10205352
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-102053522023-05-24 Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction Pham, Thao Thi Thanh Kirkpatrick, James N. Duong, Hung Duc Pham, Hung Manh Vu, Thom Thi Giap, Nguyet Thi Minh Trinh, Ha Viet Nguyen, Yen Thi Hai Hoang, Mai Thi Ngoc Nguyen, Hoai Thi Thu Ann Med Surg (Lond) Original Research The aim of this study was to determine the accuracy of two-dimensional and three-dimensional transesophageal echocardiography (TEE) in the detection of pannus and thrombus in left mechanical valve obstruction (LMVO) compared with surgical and histopathology findings. MATERIALS AND METHODS: Patients with suspected LMVO on transthoracic echocardiography were enrolled consecutively. All patients underwent two-dimensional and three-dimensional TEE, and open-heart surgery to replace obstructed valves. Macroscopic and microscopic analysis of the excised masses was used as the gold standard for the diagnosis of thrombus and/or pannus. RESULTS: Forty-eight patients [34 women (70.8%), age 49±13 years, New York Heart Association II: 68.8%, New York Heart Association III: 31.2%] were enrolled. In the diagnostic of thrombus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 89.2, 72.7, 85.4, 91.7, and 66.7%, respectively, compared with those of two-dimensional TEE (42.2, 66.7, 43.8, 95, and 7.1%, respectively). In the diagnosis of pannus, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of three-dimensional TEE were 53.3, 100, 85.4, 100, and 82.5%, respectively; compared with those of two-dimensional TEE (7.4, 90.5, 43.8, 50, and 43.2%, respectively). Receiver operating characteristic curves depict that the area under the curves of three-dimensional TEE was higher than the area under the curves of two-dimensional TEE in both diagnoses of thrombus and pannus (0.8560 vs. 0.7330, P=0.0427 and 0.8077 vs. 0.5484, P=0.005, respectively). CONCLUSIONS: This study indicated that three-dimensional TEE had a higher diagnostic value than two-dimensional TEE in the detection of thrombus and pannus in patients with LMVO, and can be a reliable imaging modality to identify the causes of LMVO. Lippincott Williams & Wilkins 2023-04-11 /pmc/articles/PMC10205352/ /pubmed/37228979 http://dx.doi.org/10.1097/MS9.0000000000000601 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Research
Pham, Thao Thi Thanh
Kirkpatrick, James N.
Duong, Hung Duc
Pham, Hung Manh
Vu, Thom Thi
Giap, Nguyet Thi Minh
Trinh, Ha Viet
Nguyen, Yen Thi Hai
Hoang, Mai Thi Ngoc
Nguyen, Hoai Thi Thu
Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
title Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
title_full Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
title_fullStr Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
title_full_unstemmed Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
title_short Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
title_sort diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10205352/
https://www.ncbi.nlm.nih.gov/pubmed/37228979
http://dx.doi.org/10.1097/MS9.0000000000000601
work_keys_str_mv AT phamthaothithanh diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT kirkpatrickjamesn diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT duonghungduc diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT phamhungmanh diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT vuthomthi diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT giapnguyetthiminh diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT trinhhaviet diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT nguyenyenthihai diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT hoangmaithingoc diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction
AT nguyenhoaithithu diagnosticaccuracyoftwodimensionalandthreedimensionaltransesophagealechocardiographyindetectingpannusandthrombusinleftmechanicalvalveobstruction