Cargando…

Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Foundation. Main funding source(s): Karl G. Andersen Foundation INTRODUCTION: External cardioversion (ECV) with transthoracic shock is a standard procedure to control atrial fibrillation and flutter in patients regardless of whether cardiovascular i...

Descripción completa

Detalles Bibliográficos
Autores principales: Elgaard, A F, Dinesen, P T, Riahi, S, Lundbye-Christensen, S, Johansen, J B, Nielsen, J C, Larsen, J M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10206809/
http://dx.doi.org/10.1093/europace/euad122.075
_version_ 1785046309230608384
author Elgaard, A F
Dinesen, P T
Riahi, S
Lundbye-Christensen, S
Johansen, J B
Nielsen, J C
Larsen, J M
author_facet Elgaard, A F
Dinesen, P T
Riahi, S
Lundbye-Christensen, S
Johansen, J B
Nielsen, J C
Larsen, J M
author_sort Elgaard, A F
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Foundation. Main funding source(s): Karl G. Andersen Foundation INTRODUCTION: External cardioversion (ECV) with transthoracic shock is a standard procedure to control atrial fibrillation and flutter in patients regardless of whether cardiovascular implantable electronic devices (CIED) are in situ. Studies have demonstrated infrequent ECV-related CIED malfunction, requiring device re-interventions, but the mechanisms seem heterogeneous. We hypothesized, that replaced CIED generators are more vulnerable to ECV procedures, maybe caused by insulation defects. The aim of this study is to investigate the long-term risk of complications following ECV in CIEDs with or without previous generator replacement. METHODS: All CIED implants and re-operations in Denmark were identified in the Danish Pacemaker and ICD Register and ECVs were identified in the Danish National Patient Registry from January 2010 to February 2019. We identified CIED patients with and without previous generator replacement. Inclusion was at the time of first ECV. Time to generator replacement with the same type and lead re-intervention with the same lead type after ECV were calculated independently, using Cox regression with death, generator extraction, and system up-/down-grade being competing events. The cause-specific hazard ratios (HR) were calculated using inverse probability of treatment balancing patient age and sex and stratified for the different types of CIED and lead, allowing different baseline hazard functions (1). RESULTS: We identified 515 CIED patients with previous generator replacement and 1,878 CIED patients without generator replacement. Mean age of patients at inclusion was 68.7±11.7 years with 74% men and the median generator and lead implant times were 1.6 years (0.9 years without replacement) and 3.0 years (0.7 years without replacement) before ECV. The types of CIED included 50% of pacemakers, 30% of Implantable Cardioverter Defibrillators, 6% of Cardiac Resynchronization Therapy-Pacemaker, and 14% of Cardiac Resynchronization Therapy-Defibrillators. During the first 3 years of follow-up, 92 (18%) of the patients with replaced generator had an additional generator replacement compared to 161 (9%) of the patients without generator replacement. The type of leads included 38% atrial leads, 26% right ventricle leads, 13% left ventricle leads, and 23% high voltage leads. During the first 3 years of follow-up, 71 (8%) of the patients with a replaced generator had lead re-intervention compared to 191 (5%) of the patients without a replaced generator. The HR of generator replacement was 2.00 (95%CI:1.51;2.64, p<0.001) and 1.60 (95%CI:1.21;2.12, p=0.001) balancing generator implant time. The HR of lead re-intervention was 1.62 (95%CI:1.21;2.16, p=0.001). CONCLUSION: Wearing a contemporary cardiovascular implantable electronic device with a prior generator replacement is associated with a two-fold increased risk of additional generator replacement and an increased risk of lead re-intervention following external cardioversion. [Figure: see text]
format Online
Article
Text
id pubmed-10206809
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102068092023-05-25 Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement Elgaard, A F Dinesen, P T Riahi, S Lundbye-Christensen, S Johansen, J B Nielsen, J C Larsen, J M Europace 10.4.3 - Rhythm Control, Cardioversion FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Foundation. Main funding source(s): Karl G. Andersen Foundation INTRODUCTION: External cardioversion (ECV) with transthoracic shock is a standard procedure to control atrial fibrillation and flutter in patients regardless of whether cardiovascular implantable electronic devices (CIED) are in situ. Studies have demonstrated infrequent ECV-related CIED malfunction, requiring device re-interventions, but the mechanisms seem heterogeneous. We hypothesized, that replaced CIED generators are more vulnerable to ECV procedures, maybe caused by insulation defects. The aim of this study is to investigate the long-term risk of complications following ECV in CIEDs with or without previous generator replacement. METHODS: All CIED implants and re-operations in Denmark were identified in the Danish Pacemaker and ICD Register and ECVs were identified in the Danish National Patient Registry from January 2010 to February 2019. We identified CIED patients with and without previous generator replacement. Inclusion was at the time of first ECV. Time to generator replacement with the same type and lead re-intervention with the same lead type after ECV were calculated independently, using Cox regression with death, generator extraction, and system up-/down-grade being competing events. The cause-specific hazard ratios (HR) were calculated using inverse probability of treatment balancing patient age and sex and stratified for the different types of CIED and lead, allowing different baseline hazard functions (1). RESULTS: We identified 515 CIED patients with previous generator replacement and 1,878 CIED patients without generator replacement. Mean age of patients at inclusion was 68.7±11.7 years with 74% men and the median generator and lead implant times were 1.6 years (0.9 years without replacement) and 3.0 years (0.7 years without replacement) before ECV. The types of CIED included 50% of pacemakers, 30% of Implantable Cardioverter Defibrillators, 6% of Cardiac Resynchronization Therapy-Pacemaker, and 14% of Cardiac Resynchronization Therapy-Defibrillators. During the first 3 years of follow-up, 92 (18%) of the patients with replaced generator had an additional generator replacement compared to 161 (9%) of the patients without generator replacement. The type of leads included 38% atrial leads, 26% right ventricle leads, 13% left ventricle leads, and 23% high voltage leads. During the first 3 years of follow-up, 71 (8%) of the patients with a replaced generator had lead re-intervention compared to 191 (5%) of the patients without a replaced generator. The HR of generator replacement was 2.00 (95%CI:1.51;2.64, p<0.001) and 1.60 (95%CI:1.21;2.12, p=0.001) balancing generator implant time. The HR of lead re-intervention was 1.62 (95%CI:1.21;2.16, p=0.001). CONCLUSION: Wearing a contemporary cardiovascular implantable electronic device with a prior generator replacement is associated with a two-fold increased risk of additional generator replacement and an increased risk of lead re-intervention following external cardioversion. [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10206809/ http://dx.doi.org/10.1093/europace/euad122.075 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 10.4.3 - Rhythm Control, Cardioversion
Elgaard, A F
Dinesen, P T
Riahi, S
Lundbye-Christensen, S
Johansen, J B
Nielsen, J C
Larsen, J M
Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
title Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
title_full Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
title_fullStr Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
title_full_unstemmed Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
title_short Risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
title_sort risk of complications following external cardioversion in cardiovascular implantable electronic devices with and without generator replacement
topic 10.4.3 - Rhythm Control, Cardioversion
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10206809/
http://dx.doi.org/10.1093/europace/euad122.075
work_keys_str_mv AT elgaardaf riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement
AT dinesenpt riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement
AT riahis riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement
AT lundbyechristensens riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement
AT johansenjb riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement
AT nielsenjc riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement
AT larsenjm riskofcomplicationsfollowingexternalcardioversionincardiovascularimplantableelectronicdeviceswithandwithoutgeneratorreplacement