Cargando…

Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. INTRODUCTION: Transcatheter atrial fibrillation (AF) ablation is in most centres commonly carried out with continuous invasive radial arterial blood pressure (BP) monitoring. Novel devices enable continuous non-invasive BP monitoring, with acc...

Descripción completa

Detalles Bibliográficos
Autores principales: Parollo, M, Di Cori, A, Fiorentini, F, De Lucia, R, Barletta, V, Viani, S, Paperini, L, Canu, A, Mazzocchetti, L, Sbragi, S, Segreti, L, Grifoni, G, Soldati, E, Zucchelli, G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10206824/
http://dx.doi.org/10.1093/europace/euad122.118
_version_ 1785046312586051584
author Parollo, M
Di Cori, A
Fiorentini, F
De Lucia, R
Barletta, V
Viani, S
Paperini, L
Canu, A
Mazzocchetti, L
Sbragi, S
Segreti, L
Grifoni, G
Soldati, E
Zucchelli, G
author_facet Parollo, M
Di Cori, A
Fiorentini, F
De Lucia, R
Barletta, V
Viani, S
Paperini, L
Canu, A
Mazzocchetti, L
Sbragi, S
Segreti, L
Grifoni, G
Soldati, E
Zucchelli, G
author_sort Parollo, M
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. INTRODUCTION: Transcatheter atrial fibrillation (AF) ablation is in most centres commonly carried out with continuous invasive radial arterial blood pressure (BP) monitoring. Novel devices enable continuous non-invasive BP monitoring, with acceptable agreement and optimal safety profile when compared to standard of care invasive BP monitoring, leading to improved patient comfort in the electrophysiology lab. PURPOSE: Aim of the study was to assess in terms of procedural efficiency continuous non-invasive BP monitoring during transcatheter atrial fibrillation ablation. METHODS: We prospectively enrolled 42 consecutive patients (age 61±9 years, 80% male) undergoing transcatheter AF ablation (60% paroxysmal, 40% persistent) at our centre undergoing AF ablation with continuous BP measurement using a non-invasive finger volume clamp device. We then compared them with an historical cohort of 42 consecutive patients undergoing AF ablation (62% paroxysmal, 38% persistent) with standard of care invasive BP monitoring with a radial cannula. We compared the two groups in terms of total procedural duration (in and out from the EP lab). RESULTS: Mean total procedural duration was 165,29±54,95 minutes in the non-invasive group and 196,55±46,67 minutes in the invasive group (P=0,006). CONCLUSION: In patients undergoing AF ablation, non-invasive finger volume-clamp continuous BP monitoring allowed for a significant reduction of total procedural duration when compared to standard of care invasive BP monitoring. Larger studies are needed to confirm these results. [Figure: see text] [Figure: see text]
format Online
Article
Text
id pubmed-10206824
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102068242023-05-25 Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration Parollo, M Di Cori, A Fiorentini, F De Lucia, R Barletta, V Viani, S Paperini, L Canu, A Mazzocchetti, L Sbragi, S Segreti, L Grifoni, G Soldati, E Zucchelli, G Europace 10.4.5 - Rhythm Control, Catheter Ablation FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. INTRODUCTION: Transcatheter atrial fibrillation (AF) ablation is in most centres commonly carried out with continuous invasive radial arterial blood pressure (BP) monitoring. Novel devices enable continuous non-invasive BP monitoring, with acceptable agreement and optimal safety profile when compared to standard of care invasive BP monitoring, leading to improved patient comfort in the electrophysiology lab. PURPOSE: Aim of the study was to assess in terms of procedural efficiency continuous non-invasive BP monitoring during transcatheter atrial fibrillation ablation. METHODS: We prospectively enrolled 42 consecutive patients (age 61±9 years, 80% male) undergoing transcatheter AF ablation (60% paroxysmal, 40% persistent) at our centre undergoing AF ablation with continuous BP measurement using a non-invasive finger volume clamp device. We then compared them with an historical cohort of 42 consecutive patients undergoing AF ablation (62% paroxysmal, 38% persistent) with standard of care invasive BP monitoring with a radial cannula. We compared the two groups in terms of total procedural duration (in and out from the EP lab). RESULTS: Mean total procedural duration was 165,29±54,95 minutes in the non-invasive group and 196,55±46,67 minutes in the invasive group (P=0,006). CONCLUSION: In patients undergoing AF ablation, non-invasive finger volume-clamp continuous BP monitoring allowed for a significant reduction of total procedural duration when compared to standard of care invasive BP monitoring. Larger studies are needed to confirm these results. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10206824/ http://dx.doi.org/10.1093/europace/euad122.118 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 10.4.5 - Rhythm Control, Catheter Ablation
Parollo, M
Di Cori, A
Fiorentini, F
De Lucia, R
Barletta, V
Viani, S
Paperini, L
Canu, A
Mazzocchetti, L
Sbragi, S
Segreti, L
Grifoni, G
Soldati, E
Zucchelli, G
Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
title Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
title_full Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
title_fullStr Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
title_full_unstemmed Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
title_short Noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
title_sort noninvasive continuous arterial pressure monitoring shortens atrial fibrillation ablation procedural duration
topic 10.4.5 - Rhythm Control, Catheter Ablation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10206824/
http://dx.doi.org/10.1093/europace/euad122.118
work_keys_str_mv AT parollom noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT dicoria noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT fiorentinif noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT deluciar noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT barlettav noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT vianis noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT paperinil noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT canua noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT mazzocchettil noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT sbragis noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT segretil noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT grifonig noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT soldatie noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration
AT zucchellig noninvasivecontinuousarterialpressuremonitoringshortensatrialfibrillationablationproceduralduration