Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): ISCIII Smartwatch with heart rate (HR) tracker measures may allow for identification of people with high resting HR who have a higher risk of atrial fibrillation (AF), a potent independ...

Descripción completa

Detalles Bibliográficos
Autores principales: Pagola, J, Meza, C M B
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207049/
http://dx.doi.org/10.1093/europace/euad122.572
_version_ 1785046363221786624
author Pagola, J
Meza, C M B
author_facet Pagola, J
Meza, C M B
author_sort Pagola, J
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): ISCIII Smartwatch with heart rate (HR) tracker measures may allow for identification of people with high resting HR who have a higher risk of atrial fibrillation (AF), a potent independent risk factor for embolic strokes. In this research, we propose a new protocol for collecting real time data of patients with cryptogenic stroke including HR at rest along with monitoring electrocardiogram (ECG). First, we assess the concordance of HR measurement between telemetry (TLM) and two smartwatches in acute stroke patients, as well as the determinants of measurement error. METHOD: We included patients over 50 years of age hospitalized in our Stroke Unit who were monitored by TLM and used the Garmin Vivosmart HR® (S1) and Fitbit Charge 5® (S2) devices. Mean HR was collected at 5, 10, 15, 20, and 25 minutes. We applied the Bland-Altman method in combination with Lin's Concordance Correlation Coefficient (CCC) to assess agreement between measurements. A coefficient CCC > 0.9 indicates acceptable agreement. RESULTS: The experimental setup was performed using 49 stroke patients (59% women, mean age 78 ± 9.86 years, and 69% with a history of AF). Poor agreement was observed between HR measurements by SI or S2 and TLM (CCC = 0.48 and 0.57 respectively), which was conditioned by the presence of AF during the measurement (CCC = -0.17 and -0.06). There was only good concordance in the absence of AF (CCC = 0.97 and 0.92). A higher percentage of error between measurements was significantly associated with a HR > 90 bpm, a history of AF, or presenting AF during the measurement (p<0.001). CONCLUSIONS: Real-time monitoring of HR at rest in each smartwatch was not accurate in acute stroke patients who had presented AF during the intake, or when HR by TLM was greater than 90. This suggests certain limitations when considering the application of processed data from this wearable technology.
format Online
Article
Text
id pubmed-10207049
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102070492023-05-25 Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit Pagola, J Meza, C M B Europace 38.7.99 - Remote Patient Monitoring and Telehealth, Other FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): ISCIII Smartwatch with heart rate (HR) tracker measures may allow for identification of people with high resting HR who have a higher risk of atrial fibrillation (AF), a potent independent risk factor for embolic strokes. In this research, we propose a new protocol for collecting real time data of patients with cryptogenic stroke including HR at rest along with monitoring electrocardiogram (ECG). First, we assess the concordance of HR measurement between telemetry (TLM) and two smartwatches in acute stroke patients, as well as the determinants of measurement error. METHOD: We included patients over 50 years of age hospitalized in our Stroke Unit who were monitored by TLM and used the Garmin Vivosmart HR® (S1) and Fitbit Charge 5® (S2) devices. Mean HR was collected at 5, 10, 15, 20, and 25 minutes. We applied the Bland-Altman method in combination with Lin's Concordance Correlation Coefficient (CCC) to assess agreement between measurements. A coefficient CCC > 0.9 indicates acceptable agreement. RESULTS: The experimental setup was performed using 49 stroke patients (59% women, mean age 78 ± 9.86 years, and 69% with a history of AF). Poor agreement was observed between HR measurements by SI or S2 and TLM (CCC = 0.48 and 0.57 respectively), which was conditioned by the presence of AF during the measurement (CCC = -0.17 and -0.06). There was only good concordance in the absence of AF (CCC = 0.97 and 0.92). A higher percentage of error between measurements was significantly associated with a HR > 90 bpm, a history of AF, or presenting AF during the measurement (p<0.001). CONCLUSIONS: Real-time monitoring of HR at rest in each smartwatch was not accurate in acute stroke patients who had presented AF during the intake, or when HR by TLM was greater than 90. This suggests certain limitations when considering the application of processed data from this wearable technology. Oxford University Press 2023-05-24 /pmc/articles/PMC10207049/ http://dx.doi.org/10.1093/europace/euad122.572 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 38.7.99 - Remote Patient Monitoring and Telehealth, Other
Pagola, J
Meza, C M B
Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
title Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
title_full Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
title_fullStr Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
title_full_unstemmed Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
title_short Accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
title_sort accuracy of real time heart rate monitoring using smartwatch in a stroke care unit
topic 38.7.99 - Remote Patient Monitoring and Telehealth, Other
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207049/
http://dx.doi.org/10.1093/europace/euad122.572
work_keys_str_mv AT pagolaj accuracyofrealtimeheartratemonitoringusingsmartwatchinastrokecareunit
AT mezacmb accuracyofrealtimeheartratemonitoringusingsmartwatchinastrokecareunit