Cargando…

Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Foundation. Main funding source(s): Magdi Yacoub foundation INTRODUCTION: Cryo balloon ablation is widely used for AF ablation. Cryo ablation techniques include regular 2 shots per vein Vs single shot freeze technique. Studies showed that the single...

Descripción completa

Detalles Bibliográficos
Autores principales: Hammouda, T, Ali, W, Mostafa, M, Mahfouz, A, Nasr, A, Nabil, S H, Elnagar, R, Kamel, O
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207061/
http://dx.doi.org/10.1093/europace/euad122.130
_version_ 1785046366170382336
author Hammouda, T
Ali, W
Mostafa, M
Mahfouz, A
Nasr, A
Nabil, S H
Elnagar, R
Kamel, O
author_facet Hammouda, T
Ali, W
Mostafa, M
Mahfouz, A
Nasr, A
Nabil, S H
Elnagar, R
Kamel, O
author_sort Hammouda, T
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Foundation. Main funding source(s): Magdi Yacoub foundation INTRODUCTION: Cryo balloon ablation is widely used for AF ablation. Cryo ablation techniques include regular 2 shots per vein Vs single shot freeze technique. Studies showed that the single shot freeze technique is as effective as the double freezing shot, thus becoming the standard technique (1). There is a debate on whether the single shot freeze should be 3 minutes or 4 minutes. Some data suggest similar efficacy while other data suggest more durable PV isolation with the 4-minute technique (2). Severe pulmonary vein (PV) stenosis is a rare but a serious complication. The only available data on iatrogenic PV stenosis are from studies on the single 3-minute freeze technique (3). PURPOSE: Assessment of the incidence of PVs stenosis using single shot 4-minute freeze technique. METHODS: We conducted a single center prospective study where we recruited 28 consecutive patients with 102 PVs scheduled for cryo AF ablation using 2nd generation cryo balloon using single shot 4-minute freeze technique as the standard technique. All patients had cardiac CT before ablation and at least 3 months post ablation where each PV’s cross-sectional area was measured. Measurements were validated by a single experienced operator. PV stenosis was classified to minimal, mild, moderate, and severe if the PV’s area decreased by 25%, 25-50%, 50-75% and more than 75% respectively. All patients were assessed regarding the presence of any symptom suggesting PV stenosis or other complications. RESULTS: Of the studied 102 PVs, only one vein (0.98%) had severe stenosis (asymptomatic) and one vein (0.98%) had moderate stenosis. Both were left superior pulmonary vein (LSPV). 13 veins (12.7%) developed mild stenosis, 74 veins (72%) showed minimal stenosis and 13 veins had no change in area. None of the studied patients developed phrenic nerve palsy or esophageal injury peri-procedure. DISCUSSION: Our results suggest low risk of developing severe PV stenosis using the 4-minute single shot freeze technique (0.98%). However, minimal, and mild pulmonary vein stenosis occurred in 84.7% of the patients denoting that this change is expected with the procedure. Tokutake et al studied the effect of using the single shot 3-minute freeze technique on PV area 3 months post cryo AF ablation and reported mild, moderate and severe (>75%) PV stenosis in 24.6%, 3.8% and 1.3% of PVs respectively (3). This shows that using the 4-minute freeze technique has a similarly low incidence of severe PV stenosis to the published data on the 3-minute technique. It appears that the LSPV is the most liable for this complication and this goes in line with the previous studies. CONCLUSION: Using the 4-minute single shot freeze technique in cryo AF ablation appears to have a comparable low incidence of severe PV stenosis to the published data for the 3-minute freeze technique. The overall risk of severe PV stenosis is low. It appears that the LSPV is the most liable for this complication.
format Online
Article
Text
id pubmed-10207061
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102070612023-05-25 Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique Hammouda, T Ali, W Mostafa, M Mahfouz, A Nasr, A Nabil, S H Elnagar, R Kamel, O Europace 10.4.5 - Rhythm Control, Catheter Ablation FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Foundation. Main funding source(s): Magdi Yacoub foundation INTRODUCTION: Cryo balloon ablation is widely used for AF ablation. Cryo ablation techniques include regular 2 shots per vein Vs single shot freeze technique. Studies showed that the single shot freeze technique is as effective as the double freezing shot, thus becoming the standard technique (1). There is a debate on whether the single shot freeze should be 3 minutes or 4 minutes. Some data suggest similar efficacy while other data suggest more durable PV isolation with the 4-minute technique (2). Severe pulmonary vein (PV) stenosis is a rare but a serious complication. The only available data on iatrogenic PV stenosis are from studies on the single 3-minute freeze technique (3). PURPOSE: Assessment of the incidence of PVs stenosis using single shot 4-minute freeze technique. METHODS: We conducted a single center prospective study where we recruited 28 consecutive patients with 102 PVs scheduled for cryo AF ablation using 2nd generation cryo balloon using single shot 4-minute freeze technique as the standard technique. All patients had cardiac CT before ablation and at least 3 months post ablation where each PV’s cross-sectional area was measured. Measurements were validated by a single experienced operator. PV stenosis was classified to minimal, mild, moderate, and severe if the PV’s area decreased by 25%, 25-50%, 50-75% and more than 75% respectively. All patients were assessed regarding the presence of any symptom suggesting PV stenosis or other complications. RESULTS: Of the studied 102 PVs, only one vein (0.98%) had severe stenosis (asymptomatic) and one vein (0.98%) had moderate stenosis. Both were left superior pulmonary vein (LSPV). 13 veins (12.7%) developed mild stenosis, 74 veins (72%) showed minimal stenosis and 13 veins had no change in area. None of the studied patients developed phrenic nerve palsy or esophageal injury peri-procedure. DISCUSSION: Our results suggest low risk of developing severe PV stenosis using the 4-minute single shot freeze technique (0.98%). However, minimal, and mild pulmonary vein stenosis occurred in 84.7% of the patients denoting that this change is expected with the procedure. Tokutake et al studied the effect of using the single shot 3-minute freeze technique on PV area 3 months post cryo AF ablation and reported mild, moderate and severe (>75%) PV stenosis in 24.6%, 3.8% and 1.3% of PVs respectively (3). This shows that using the 4-minute freeze technique has a similarly low incidence of severe PV stenosis to the published data on the 3-minute technique. It appears that the LSPV is the most liable for this complication and this goes in line with the previous studies. CONCLUSION: Using the 4-minute single shot freeze technique in cryo AF ablation appears to have a comparable low incidence of severe PV stenosis to the published data for the 3-minute freeze technique. The overall risk of severe PV stenosis is low. It appears that the LSPV is the most liable for this complication. Oxford University Press 2023-05-24 /pmc/articles/PMC10207061/ http://dx.doi.org/10.1093/europace/euad122.130 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 10.4.5 - Rhythm Control, Catheter Ablation
Hammouda, T
Ali, W
Mostafa, M
Mahfouz, A
Nasr, A
Nabil, S H
Elnagar, R
Kamel, O
Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
title Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
title_full Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
title_fullStr Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
title_full_unstemmed Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
title_short Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
title_sort pulmonary vein stenosis post cryo af ablation using single shot 4-minute freeze technique
topic 10.4.5 - Rhythm Control, Catheter Ablation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207061/
http://dx.doi.org/10.1093/europace/euad122.130
work_keys_str_mv AT hammoudat pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT aliw pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT mostafam pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT mahfouza pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT nasra pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT nabilsh pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT elnagarr pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique
AT kamelo pulmonaryveinstenosispostcryoafablationusingsingleshot4minutefreezetechnique