Cargando…
Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation
FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Pulsed field ablation (PFA) has recently been introduced as a novel routine ablation technology for paroxysmal atrial fibrillation (PAF). PFA can be performed "cryo-style" using fluoroscopy only, or additional pre- and po...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207075/ http://dx.doi.org/10.1093/europace/euad122.108 |
_version_ | 1785046369449279488 |
---|---|
author | Neven, K Fueting, A Hartl, S Reinsch, N |
author_facet | Neven, K Fueting, A Hartl, S Reinsch, N |
author_sort | Neven, K |
collection | PubMed |
description | FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Pulsed field ablation (PFA) has recently been introduced as a novel routine ablation technology for paroxysmal atrial fibrillation (PAF). PFA can be performed "cryo-style" using fluoroscopy only, or additional pre- and post-ablation high-density 3D bipolar voltage maps can be performed to assess lesion formation and acute pulmonary vein isolation. We compared 6-month outcome after PFA using fluoroscopy only (X-ray) vs. PFA guided by 3D mapping (3D). METHODS: In PAF patients, PVI in conscious sedation using a steerable sheath and a pentaspline over-the-wire basket and flower PFA catheter was performed. In a subset of patients, pre- and post-ablation high-density bipolar voltage 3D maps (Carto 3D) were performed. Procedural parameters, acute success, in-hospital safety and arrhythmia recurrence were assessed over 6-month follow-up. Efficacy was evaluated by freedom from a ≥ 30-sec. recurrence of AF/atrial flutter (AFL)/atrial tachycardia (AT). Follow-up included 7-day Holter ECGs and/or telephonic interviews at days 90 and 180 after ablation. RESULTS: This study included a total of 101 patients (mean age: 65±10 years; 42% female) in whom 6-month follow-up data were available. There were no selection criteria for the use of 3D mapping. Pre- and post-ablation high-density maps were performed in 34/101 (34%) of patients. Mean CHA2DS2-VASc-score was 2,1±1,6. Median duration since first AF diagnosis was 21 [3-60] months. Skin-to skin procedure time was 56±20 in the X-ray group vs. 118±22 min in the 3D group, respectively (p<0,0001). Fluoroscopy time was 17±7 in the X-ray group vs. 21±6 in the 3D group, respectively (p<0,01). Acute pulmonary vein isolation rate was 100% in both groups. Primary adverse events occurred in 0% of patients in the X-ray group vs. 2/34 (6%) in the 3D group (2 pericardial tamponades), respectively (p=ns). During a mean follow-up of 204±82 days, 54/67 (81%) in the X-ray group vs. 27/34 (79%) in the 3D group remained free of any symptomatic or documented AF/AFL/AT episode after a single procedure (p=ns). In 4/13 (31%) patients in the X-ray group, a re-do procedure was performed, 2 patients had durable PVI with typical or atypical atrial flutter, 1 patient had reconnection of both posterior carinae and 1 patient had typical atrial flutter degenerating in AF. In 3/7 (43%) patients in the 3D group, a re-do procedure was performed, 2 patients had durable PVI with typical or atypical atrial flutter and 1 patient had reconnection of the LIPV. CONCLUSIONS: PVI using PFA with or without 3D mapping system resulted in a similar 6-month atrial arrhythmia recurrence rate and safety profile. Procedure and fluoroscopy times were significantly shorter in the fluoroscopy only group. |
format | Online Article Text |
id | pubmed-10207075 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-102070752023-05-25 Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation Neven, K Fueting, A Hartl, S Reinsch, N Europace 10.4.5 - Rhythm Control, Catheter Ablation FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Pulsed field ablation (PFA) has recently been introduced as a novel routine ablation technology for paroxysmal atrial fibrillation (PAF). PFA can be performed "cryo-style" using fluoroscopy only, or additional pre- and post-ablation high-density 3D bipolar voltage maps can be performed to assess lesion formation and acute pulmonary vein isolation. We compared 6-month outcome after PFA using fluoroscopy only (X-ray) vs. PFA guided by 3D mapping (3D). METHODS: In PAF patients, PVI in conscious sedation using a steerable sheath and a pentaspline over-the-wire basket and flower PFA catheter was performed. In a subset of patients, pre- and post-ablation high-density bipolar voltage 3D maps (Carto 3D) were performed. Procedural parameters, acute success, in-hospital safety and arrhythmia recurrence were assessed over 6-month follow-up. Efficacy was evaluated by freedom from a ≥ 30-sec. recurrence of AF/atrial flutter (AFL)/atrial tachycardia (AT). Follow-up included 7-day Holter ECGs and/or telephonic interviews at days 90 and 180 after ablation. RESULTS: This study included a total of 101 patients (mean age: 65±10 years; 42% female) in whom 6-month follow-up data were available. There were no selection criteria for the use of 3D mapping. Pre- and post-ablation high-density maps were performed in 34/101 (34%) of patients. Mean CHA2DS2-VASc-score was 2,1±1,6. Median duration since first AF diagnosis was 21 [3-60] months. Skin-to skin procedure time was 56±20 in the X-ray group vs. 118±22 min in the 3D group, respectively (p<0,0001). Fluoroscopy time was 17±7 in the X-ray group vs. 21±6 in the 3D group, respectively (p<0,01). Acute pulmonary vein isolation rate was 100% in both groups. Primary adverse events occurred in 0% of patients in the X-ray group vs. 2/34 (6%) in the 3D group (2 pericardial tamponades), respectively (p=ns). During a mean follow-up of 204±82 days, 54/67 (81%) in the X-ray group vs. 27/34 (79%) in the 3D group remained free of any symptomatic or documented AF/AFL/AT episode after a single procedure (p=ns). In 4/13 (31%) patients in the X-ray group, a re-do procedure was performed, 2 patients had durable PVI with typical or atypical atrial flutter, 1 patient had reconnection of both posterior carinae and 1 patient had typical atrial flutter degenerating in AF. In 3/7 (43%) patients in the 3D group, a re-do procedure was performed, 2 patients had durable PVI with typical or atypical atrial flutter and 1 patient had reconnection of the LIPV. CONCLUSIONS: PVI using PFA with or without 3D mapping system resulted in a similar 6-month atrial arrhythmia recurrence rate and safety profile. Procedure and fluoroscopy times were significantly shorter in the fluoroscopy only group. Oxford University Press 2023-05-24 /pmc/articles/PMC10207075/ http://dx.doi.org/10.1093/europace/euad122.108 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | 10.4.5 - Rhythm Control, Catheter Ablation Neven, K Fueting, A Hartl, S Reinsch, N Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation |
title | Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation |
title_full | Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation |
title_fullStr | Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation |
title_full_unstemmed | Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation |
title_short | Safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3D mapping system for paroxysmal atrial fibrillation |
title_sort | safety and efficacy of pulmonary vein isolation using pulsed field ablation with or without 3d mapping system for paroxysmal atrial fibrillation |
topic | 10.4.5 - Rhythm Control, Catheter Ablation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207075/ http://dx.doi.org/10.1093/europace/euad122.108 |
work_keys_str_mv | AT nevenk safetyandefficacyofpulmonaryveinisolationusingpulsedfieldablationwithorwithout3dmappingsystemforparoxysmalatrialfibrillation AT fuetinga safetyandefficacyofpulmonaryveinisolationusingpulsedfieldablationwithorwithout3dmappingsystemforparoxysmalatrialfibrillation AT hartls safetyandefficacyofpulmonaryveinisolationusingpulsedfieldablationwithorwithout3dmappingsystemforparoxysmalatrialfibrillation AT reinschn safetyandefficacyofpulmonaryveinisolationusingpulsedfieldablationwithorwithout3dmappingsystemforparoxysmalatrialfibrillation |