Cargando…
QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators
FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – EU funding. Main funding source(s): European Community’s 7th Framework Programme (HEALTH-F2-2009-602299) Ministry of Health, Czech Republic BACKGROUND: Three-dimensional (e.g., vectorcardiography) loops of normal physiologic QRS co...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207134/ http://dx.doi.org/10.1093/europace/euad122.345 |
_version_ | 1785046383427846144 |
---|---|
author | Novotny, T Hnatkova, K Andrsova, I Vandenberk, B Sprenkeler, D J Junttila, J Reichlin, T Schloegl, S Friede, T Bauer, A Willems, R Schmidt, G Sticherling, C Zabel, M Malik, M |
author_facet | Novotny, T Hnatkova, K Andrsova, I Vandenberk, B Sprenkeler, D J Junttila, J Reichlin, T Schloegl, S Friede, T Bauer, A Willems, R Schmidt, G Sticherling, C Zabel, M Malik, M |
author_sort | Novotny, T |
collection | PubMed |
description | FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – EU funding. Main funding source(s): European Community’s 7th Framework Programme (HEALTH-F2-2009-602299) Ministry of Health, Czech Republic BACKGROUND: Three-dimensional (e.g., vectorcardiography) loops of normal physiologic QRS complex and T wave are known to be planar. Non-planarity of these electrocardiogram (ECG) loops was described in cardiac patients, mainly in relation to ischemic heart disease, but predictive values of the extent of non-planarity of the loops have not been systematically researched. METHODS: Pre-implantation digital ECGs were collected in 1948 cardiac patients (381 females, median age 65, inter-quartile range 56 – 72 years, 62% ischemic heart disease) who obtained an implantable cardioverter-defibrillator (ICD) for primary prophylactic reasons. In each ECG, QRS and T wave 3-dimensional loops were constructed using singular value decomposition and the non-planarity of the loops was measured as the relative power of the 3rd, least significant decomposition component. The non-planarity (i.e., the spatial twist) of the loops was related to all-cause mortality and to appropriate ICD shocks that occurred during the first 5 years after device implantation. This predictive power was compared to that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval, and T-peak to T-end interval. RESULTS: Non-planarity of the QRS loop was significantly associated with follow-up deaths despite ICD protection (p<0.001 both univariably and in multivariable Cox regression analysis) but was less powerfully associated with appropriate ICD shocks. Non-planarity of the T wave loop was significantly associated with appropriate ICD shocks during follow-up (p<0.001 both univariably and in multivariable Cox regression analysis) but was not associated with mortality during follow-up (Table). This was also seen in significant separation of Kaplan-Meier event probability curves (Figure). CONCLUSIONS: The analysed data of recipients of prophylactic ICDs suggest that non-planarity of QRS complex and T wave loops offers distinction between patients who are at greater risk of death despite ICD protection and those who are likely to utilize the defibrillator protection. [Figure: see text] [Figure: see text] |
format | Online Article Text |
id | pubmed-10207134 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-102071342023-05-25 QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators Novotny, T Hnatkova, K Andrsova, I Vandenberk, B Sprenkeler, D J Junttila, J Reichlin, T Schloegl, S Friede, T Bauer, A Willems, R Schmidt, G Sticherling, C Zabel, M Malik, M Europace 13.4.4 - Device Treatment FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – EU funding. Main funding source(s): European Community’s 7th Framework Programme (HEALTH-F2-2009-602299) Ministry of Health, Czech Republic BACKGROUND: Three-dimensional (e.g., vectorcardiography) loops of normal physiologic QRS complex and T wave are known to be planar. Non-planarity of these electrocardiogram (ECG) loops was described in cardiac patients, mainly in relation to ischemic heart disease, but predictive values of the extent of non-planarity of the loops have not been systematically researched. METHODS: Pre-implantation digital ECGs were collected in 1948 cardiac patients (381 females, median age 65, inter-quartile range 56 – 72 years, 62% ischemic heart disease) who obtained an implantable cardioverter-defibrillator (ICD) for primary prophylactic reasons. In each ECG, QRS and T wave 3-dimensional loops were constructed using singular value decomposition and the non-planarity of the loops was measured as the relative power of the 3rd, least significant decomposition component. The non-planarity (i.e., the spatial twist) of the loops was related to all-cause mortality and to appropriate ICD shocks that occurred during the first 5 years after device implantation. This predictive power was compared to that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval, and T-peak to T-end interval. RESULTS: Non-planarity of the QRS loop was significantly associated with follow-up deaths despite ICD protection (p<0.001 both univariably and in multivariable Cox regression analysis) but was less powerfully associated with appropriate ICD shocks. Non-planarity of the T wave loop was significantly associated with appropriate ICD shocks during follow-up (p<0.001 both univariably and in multivariable Cox regression analysis) but was not associated with mortality during follow-up (Table). This was also seen in significant separation of Kaplan-Meier event probability curves (Figure). CONCLUSIONS: The analysed data of recipients of prophylactic ICDs suggest that non-planarity of QRS complex and T wave loops offers distinction between patients who are at greater risk of death despite ICD protection and those who are likely to utilize the defibrillator protection. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207134/ http://dx.doi.org/10.1093/europace/euad122.345 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | 13.4.4 - Device Treatment Novotny, T Hnatkova, K Andrsova, I Vandenberk, B Sprenkeler, D J Junttila, J Reichlin, T Schloegl, S Friede, T Bauer, A Willems, R Schmidt, G Sticherling, C Zabel, M Malik, M QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
title | QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
title_full | QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
title_fullStr | QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
title_full_unstemmed | QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
title_short | QRS complex and T wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
title_sort | qrs complex and t wave planarity for the prediction of death and appropriate shocks in recipients of prophylactic implantable defibrillators |
topic | 13.4.4 - Device Treatment |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207134/ http://dx.doi.org/10.1093/europace/euad122.345 |
work_keys_str_mv | AT novotnyt qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT hnatkovak qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT andrsovai qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT vandenberkb qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT sprenkelerdj qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT junttilaj qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT reichlint qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT schloegls qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT friedet qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT bauera qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT willemsr qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT schmidtg qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT sticherlingc qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT zabelm qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators AT malikm qrscomplexandtwaveplanarityforthepredictionofdeathandappropriateshocksinrecipientsofprophylacticimplantabledefibrillators |