Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Leadless pacemakers (LP) capable of VDD function are a cornerstone of modern pacemaker therapy reducing complications in elderly patients while enabling atrioventricular synchrony through mechanical sensing of atrial contraction. B...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofer, D, Perucchini, F, Zehetleitner, S, Saguner, A, Haeberlin, A, Steffel, J, Breitenstein, A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207250/
http://dx.doi.org/10.1093/europace/euad122.398
_version_ 1785046410751639552
author Hofer, D
Perucchini, F
Zehetleitner, S
Saguner, A
Haeberlin, A
Steffel, J
Breitenstein, A
author_facet Hofer, D
Perucchini, F
Zehetleitner, S
Saguner, A
Haeberlin, A
Steffel, J
Breitenstein, A
author_sort Hofer, D
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Leadless pacemakers (LP) capable of VDD function are a cornerstone of modern pacemaker therapy reducing complications in elderly patients while enabling atrioventricular synchrony through mechanical sensing of atrial contraction. Because mechanical sensing is less reliable than electrical sensing, the reliability of VDD function in LP varies. We evaluated the p-wave amplitude from patient ECGs as a predictor for successful VDD function in LP. MATERIALS AND METHODS: Consecutive patients undergoing LP implantation capable of VDD function were included in this multi-center retrospective cohort study. As VDD function is mainly dependent on the A4 signal amplitude in the current generation of the device, ECG parameters pre-implantation were evaluated separately and in combination for association with A4 signal amplitude post-implantation. RESULTS: 122 Patients (mean age 81, female 44%, mean BMI 25.9 kg/m2) were included. Main indication for LP implantation was AV-Block (70%). BMI-adjusted P-wave amplitude demonstrated a statistically significant positive correlation with A4 signal amplitude in leads I, II, aVL, aVF, aVR, V1 and V2 (all p<0.05). A p-wave amplitude of at least 0.1mV had a specificity of 72% (95%-CI 50%-89%) for a good A4 signal. A sum of at least 0.2mV of p-wave amplitudes in V1 and aVL predicts a specificity of 83% (95%-CI 67-100%) for a good A4 signal. CONCLUSIONS: P-wave amplitudes in selected ECG leads can predict A4 signal amplitude and therefore the reliability of VDD function in LP. [Figure: see text] [Figure: see text]
format Online
Article
Text
id pubmed-10207250
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102072502023-05-25 Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers Hofer, D Perucchini, F Zehetleitner, S Saguner, A Haeberlin, A Steffel, J Breitenstein, A Europace 14.1 - Antibradycardia Pacing FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Leadless pacemakers (LP) capable of VDD function are a cornerstone of modern pacemaker therapy reducing complications in elderly patients while enabling atrioventricular synchrony through mechanical sensing of atrial contraction. Because mechanical sensing is less reliable than electrical sensing, the reliability of VDD function in LP varies. We evaluated the p-wave amplitude from patient ECGs as a predictor for successful VDD function in LP. MATERIALS AND METHODS: Consecutive patients undergoing LP implantation capable of VDD function were included in this multi-center retrospective cohort study. As VDD function is mainly dependent on the A4 signal amplitude in the current generation of the device, ECG parameters pre-implantation were evaluated separately and in combination for association with A4 signal amplitude post-implantation. RESULTS: 122 Patients (mean age 81, female 44%, mean BMI 25.9 kg/m2) were included. Main indication for LP implantation was AV-Block (70%). BMI-adjusted P-wave amplitude demonstrated a statistically significant positive correlation with A4 signal amplitude in leads I, II, aVL, aVF, aVR, V1 and V2 (all p<0.05). A p-wave amplitude of at least 0.1mV had a specificity of 72% (95%-CI 50%-89%) for a good A4 signal. A sum of at least 0.2mV of p-wave amplitudes in V1 and aVL predicts a specificity of 83% (95%-CI 67-100%) for a good A4 signal. CONCLUSIONS: P-wave amplitudes in selected ECG leads can predict A4 signal amplitude and therefore the reliability of VDD function in LP. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207250/ http://dx.doi.org/10.1093/europace/euad122.398 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 14.1 - Antibradycardia Pacing
Hofer, D
Perucchini, F
Zehetleitner, S
Saguner, A
Haeberlin, A
Steffel, J
Breitenstein, A
Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers
title Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers
title_full Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers
title_fullStr Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers
title_full_unstemmed Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers
title_short Electrocardiographic predictors of atrial mechanical sensing in patients with leadless VDD pacemakers
title_sort electrocardiographic predictors of atrial mechanical sensing in patients with leadless vdd pacemakers
topic 14.1 - Antibradycardia Pacing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207250/
http://dx.doi.org/10.1093/europace/euad122.398
work_keys_str_mv AT hoferd electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers
AT perucchinif electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers
AT zehetleitners electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers
AT sagunera electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers
AT haeberlina electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers
AT steffelj electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers
AT breitensteina electrocardiographicpredictorsofatrialmechanicalsensinginpatientswithleadlessvddpacemakers