Using a smartwatch to record precordial electrocardiograms: a validation study

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): This work received financial support from the French Government as part of the “Investments of the Future” program managed by the National Research Agency (ANR) BACKGROUND: Smartwatches...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Der Zande, J L, Strik, M, Dubois, R, Ploux, S, Abu-Alrub, S, Donker, D W, Oppersma, E, Bordachar, P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207286/
http://dx.doi.org/10.1093/europace/euad122.637
_version_ 1785046418739691520
author Van Der Zande, J L
Strik, M
Dubois, R
Ploux, S
Abu-Alrub, S
Donker, D W
Oppersma, E
Bordachar, P
author_facet Van Der Zande, J L
Strik, M
Dubois, R
Ploux, S
Abu-Alrub, S
Donker, D W
Oppersma, E
Bordachar, P
author_sort Van Der Zande, J L
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): This work received financial support from the French Government as part of the “Investments of the Future” program managed by the National Research Agency (ANR) BACKGROUND: Smartwatches which support recording of a single-lead electrocardiogram (ECG) are increasingly being used worldwide, mainly for detection of atrial fibrillation. Recordings beyond the wrist are anecdotal as their reliability remains unknown. AIM: This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain frontal and precordial leads as compared with standard 12-lead ECGs in both healthy subjects and patients with underlying heart disease. METHODS: In 100 subjects (80 with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland-Altman analysis including bias (mean difference), absolute offset (mean absolute difference), and 95% limits of agreement. RESULTS: No significant differences were observed for any parameter across any lead, except for R-wave measured across precordial leads V1, V3, and V6 where significantly greater amplitudes were measured by the AW, (0.20 mV; 0.19mV; 0.49 mV respectively; p = 9x10-7; p = 7x10-4; p = 6x10-14, respectively), indicating overestimation by the AW. There were no significant differences in absolute offset or bias for any parameters of any leads (p > 0.05). CONCLUSION: ECGs recorded with the AW on the wrist but also on other positions had comparable durations and amplitudes compared to standard 12-lead ECG. The AW can be used to record frontal and precordial leads, paving the way for broader clinical applications. [Figure: see text] [Figure: see text]
format Online
Article
Text
id pubmed-10207286
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102072862023-05-25 Using a smartwatch to record precordial electrocardiograms: a validation study Van Der Zande, J L Strik, M Dubois, R Ploux, S Abu-Alrub, S Donker, D W Oppersma, E Bordachar, P Europace 9.3.7 - Noninvasive Diagnostic Methods FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): This work received financial support from the French Government as part of the “Investments of the Future” program managed by the National Research Agency (ANR) BACKGROUND: Smartwatches which support recording of a single-lead electrocardiogram (ECG) are increasingly being used worldwide, mainly for detection of atrial fibrillation. Recordings beyond the wrist are anecdotal as their reliability remains unknown. AIM: This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain frontal and precordial leads as compared with standard 12-lead ECGs in both healthy subjects and patients with underlying heart disease. METHODS: In 100 subjects (80 with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland-Altman analysis including bias (mean difference), absolute offset (mean absolute difference), and 95% limits of agreement. RESULTS: No significant differences were observed for any parameter across any lead, except for R-wave measured across precordial leads V1, V3, and V6 where significantly greater amplitudes were measured by the AW, (0.20 mV; 0.19mV; 0.49 mV respectively; p = 9x10-7; p = 7x10-4; p = 6x10-14, respectively), indicating overestimation by the AW. There were no significant differences in absolute offset or bias for any parameters of any leads (p > 0.05). CONCLUSION: ECGs recorded with the AW on the wrist but also on other positions had comparable durations and amplitudes compared to standard 12-lead ECG. The AW can be used to record frontal and precordial leads, paving the way for broader clinical applications. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207286/ http://dx.doi.org/10.1093/europace/euad122.637 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.3.7 - Noninvasive Diagnostic Methods
Van Der Zande, J L
Strik, M
Dubois, R
Ploux, S
Abu-Alrub, S
Donker, D W
Oppersma, E
Bordachar, P
Using a smartwatch to record precordial electrocardiograms: a validation study
title Using a smartwatch to record precordial electrocardiograms: a validation study
title_full Using a smartwatch to record precordial electrocardiograms: a validation study
title_fullStr Using a smartwatch to record precordial electrocardiograms: a validation study
title_full_unstemmed Using a smartwatch to record precordial electrocardiograms: a validation study
title_short Using a smartwatch to record precordial electrocardiograms: a validation study
title_sort using a smartwatch to record precordial electrocardiograms: a validation study
topic 9.3.7 - Noninvasive Diagnostic Methods
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207286/
http://dx.doi.org/10.1093/europace/euad122.637
work_keys_str_mv AT vanderzandejl usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT strikm usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT duboisr usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT plouxs usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT abualrubs usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT donkerdw usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT oppersmae usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy
AT bordacharp usingasmartwatchtorecordprecordialelectrocardiogramsavalidationstudy