Cargando…

Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: It has been shown recently that ablation of paroxysmal and persistent atrial fibrillation (AF) using very high-power-short duration (vHPSD) ablation protocol is safe and effective. Data for vHPSD ablation protocol in adult patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Lengauer, S, Telishevska, M, Krafft, K, Bahlke, B, Englert, E, Lennerz, L, Popa, P, Reents, R, Deisenhofer, D, Hessing, H
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207338/
http://dx.doi.org/10.1093/europace/euad122.725
_version_ 1785046431148539904
author Lengauer, S
Telishevska, M
Krafft, K
Bahlke, B
Englert, E
Lennerz, L
Popa, P
Reents, R
Deisenhofer, D
Hessing, H
author_facet Lengauer, S
Telishevska, M
Krafft, K
Bahlke, B
Englert, E
Lennerz, L
Popa, P
Reents, R
Deisenhofer, D
Hessing, H
author_sort Lengauer, S
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: It has been shown recently that ablation of paroxysmal and persistent atrial fibrillation (AF) using very high-power-short duration (vHPSD) ablation protocol is safe and effective. Data for vHPSD ablation protocol in adult patients with congenital heart disease (ACHD) are lacking. We searched our database for ACHD patients undergoing AF ablation using vHPSD ablation regarding periprocedural safety and outcome. METHODS: The data of 62 consecutive ACHD patients with mild (n=43; 69.4%), moderate (n=15; 24.2%) or complex (n= 4; 6.4%) CHD were analysed (Table 1 ). Mean age was 60,43 ± 12,7 years ( 46% male) with a Cha2ds2-VASc2 Score median of 2. Patients were diagnosed with paroxysmal AF (n= 24; 38%) or persistent AF (n= 38; 61%). In 6 patients (9,6 %), a previous conventional pulmonary vein isolation (PVI) had been performed. Settings used for vHPSD ablation were 70 W/5-7 s or 60 W/7-10 s using irrigated-tip catheters. Circumferential PVI was performed in all 62 patients; in 30 patients (48%) additional substrate ablation was performed. The 30-day incidence of adverse events was analyzed and patients followed-up in regular visits at our outpatient clinic using repetitive 7 days Holter ECGs every 3 months. RESULTS: No adverse events such as cardiac tamponade, pericardial effusion >10mm, transient ischemic attack/stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Vascular access complications were detected in 7/62 patients (11%), including 4 patients with a need of intervention (surgical n=2, thrombin injection n=2). Complete PVI was performed in all patients (mean procedure time 129 ± 42min, mean fluoroscopy time 9,09 ± 5.44 min. Radiofrequency (RF) time was 127.27 ± 7,25 min (111,43 ± 27,83 min PVI only, 148,76 ± 46,07 min PVI + substrate ablation). After a mean follow up of 249 days, freedom of any atrial arrhythmia off antiarrhythmic drugs (AAD) after a single ablation procedure was present in 26/47 patients (55.3%). Success rate was significantly higher in patients with paroxysmal AF (n=16/18; 88%) compared to patients with persistent AF (n=10/29; 34.5%; p< 0.001; Figure 1) Conclusion: In this first study using vHPSD in ACHD patients of variable complexity with paroxysmal or persistent AF, the technique was safe and effective. Major periprocedural complications were rare and limited to vascular access problems. No vHPSD ablation modality-related complications occurred. vHPSD was fast in all patintes regardless of CHD complexity. Results in the paroxysmal CHD group were excellent and encouraging for persistent AF. [Figure: see text] [Figure: see text]
format Online
Article
Text
id pubmed-10207338
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102073382023-05-25 Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome Lengauer, S Telishevska, M Krafft, K Bahlke, B Englert, E Lennerz, L Popa, P Reents, R Deisenhofer, D Hessing, H Europace 9.4.4 - Catheter Ablation of Arrhythmias FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: It has been shown recently that ablation of paroxysmal and persistent atrial fibrillation (AF) using very high-power-short duration (vHPSD) ablation protocol is safe and effective. Data for vHPSD ablation protocol in adult patients with congenital heart disease (ACHD) are lacking. We searched our database for ACHD patients undergoing AF ablation using vHPSD ablation regarding periprocedural safety and outcome. METHODS: The data of 62 consecutive ACHD patients with mild (n=43; 69.4%), moderate (n=15; 24.2%) or complex (n= 4; 6.4%) CHD were analysed (Table 1 ). Mean age was 60,43 ± 12,7 years ( 46% male) with a Cha2ds2-VASc2 Score median of 2. Patients were diagnosed with paroxysmal AF (n= 24; 38%) or persistent AF (n= 38; 61%). In 6 patients (9,6 %), a previous conventional pulmonary vein isolation (PVI) had been performed. Settings used for vHPSD ablation were 70 W/5-7 s or 60 W/7-10 s using irrigated-tip catheters. Circumferential PVI was performed in all 62 patients; in 30 patients (48%) additional substrate ablation was performed. The 30-day incidence of adverse events was analyzed and patients followed-up in regular visits at our outpatient clinic using repetitive 7 days Holter ECGs every 3 months. RESULTS: No adverse events such as cardiac tamponade, pericardial effusion >10mm, transient ischemic attack/stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Vascular access complications were detected in 7/62 patients (11%), including 4 patients with a need of intervention (surgical n=2, thrombin injection n=2). Complete PVI was performed in all patients (mean procedure time 129 ± 42min, mean fluoroscopy time 9,09 ± 5.44 min. Radiofrequency (RF) time was 127.27 ± 7,25 min (111,43 ± 27,83 min PVI only, 148,76 ± 46,07 min PVI + substrate ablation). After a mean follow up of 249 days, freedom of any atrial arrhythmia off antiarrhythmic drugs (AAD) after a single ablation procedure was present in 26/47 patients (55.3%). Success rate was significantly higher in patients with paroxysmal AF (n=16/18; 88%) compared to patients with persistent AF (n=10/29; 34.5%; p< 0.001; Figure 1) Conclusion: In this first study using vHPSD in ACHD patients of variable complexity with paroxysmal or persistent AF, the technique was safe and effective. Major periprocedural complications were rare and limited to vascular access problems. No vHPSD ablation modality-related complications occurred. vHPSD was fast in all patintes regardless of CHD complexity. Results in the paroxysmal CHD group were excellent and encouraging for persistent AF. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207338/ http://dx.doi.org/10.1093/europace/euad122.725 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.4.4 - Catheter Ablation of Arrhythmias
Lengauer, S
Telishevska, M
Krafft, K
Bahlke, B
Englert, E
Lennerz, L
Popa, P
Reents, R
Deisenhofer, D
Hessing, H
Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
title Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
title_full Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
title_fullStr Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
title_full_unstemmed Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
title_short Very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
title_sort very high power- short duration radiofrequency ablation in patients with congenital heart disease and atrial fibrillation: safety and outcome
topic 9.4.4 - Catheter Ablation of Arrhythmias
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207338/
http://dx.doi.org/10.1093/europace/euad122.725
work_keys_str_mv AT lengauers veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT telishevskam veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT krafftk veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT bahlkeb veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT englerte veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT lennerzl veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT popap veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT reentsr veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT deisenhoferd veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome
AT hessingh veryhighpowershortdurationradiofrequencyablationinpatientswithcongenitalheartdiseaseandatrialfibrillationsafetyandoutcome