Cargando…

Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Ablation procedures for cavo-tricuspid isthmus (CTI) dependent typical atrial flutter (AFL) have traditionally been performed with conventional electrophysiology mapping guided by fluoroscopy. Three-dimensional electroanatomical ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodriguez, O R, Zaraket, F Z, Gonzalez, C G, Casteigt, B C, Jimenez, J J, Valles Gras, E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207368/
http://dx.doi.org/10.1093/europace/euad122.234
_version_ 1785046438418317312
author Rodriguez, O R
Zaraket, F Z
Gonzalez, C G
Casteigt, B C
Jimenez, J J
Valles Gras, E
author_facet Rodriguez, O R
Zaraket, F Z
Gonzalez, C G
Casteigt, B C
Jimenez, J J
Valles Gras, E
author_sort Rodriguez, O R
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Ablation procedures for cavo-tricuspid isthmus (CTI) dependent typical atrial flutter (AFL) have traditionally been performed with conventional electrophysiology mapping guided by fluoroscopy. Three-dimensional electroanatomical mapping (EAM) systems have routinely been used to guide ablation of more complex arrhythmias, but in recent years, have been used for simple ablations with the aim of reducing irradiation. High voltage regions in the CTI have been described as a target in order to minimize procedure times, but there is a lack of knowledge regarding the utility of slow conduction zones for this purpose. METHODS: In a prospective cohort of patients undergoing 3D EAM assisted AFL ablation, we evaluated a novel strategy (NS) based on omnipolar vectors, using both wave speed and voltage information to focus radiofrequency (RF) lesions (see figure), and compared with a recent retrospective cohort of patients undergoing voltage-guided ablation (VG). RESULTS: A group of 26 consecutive patients with mean age 68±12 years and 88% male, underwent NS ablation, and were compared to 23 patients undergoing VG ablation, with no differences among patient characteristics. Of the 26 patients in group NS, 16 (53.9%) were successfully ablated targeting only 2 sites, representing the 2 most confluent areas of low wave speed and high voltage. A total of 24 (92.5%) were ablated successfully with targeting all sites of low wave speed. Only a single patient in the NS group required the completion of a classic CTI line. Average fluoroscopy time and radiation dose were lower in the NS group compared to VG group (1.1±2.4 min 19.5±41.7 mGray vs 8.2±10.2 min and 64.4±76.5 mGray, p=0.0014 and p=0.013, respectively). Furthermore, RF time trended towards reduction in the NS group. CONCLUSIONS: A strategy based on targeting only areas of low wave speed is effective, limiting the need to complete a traditional CTI line, and reducing fluoroscopy in patients undergoin CTI ablation. [Figure: see text]
format Online
Article
Text
id pubmed-10207368
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102073682023-05-25 Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter Rodriguez, O R Zaraket, F Z Gonzalez, C G Casteigt, B C Jimenez, J J Valles Gras, E Europace 11.4 - Treatment FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Ablation procedures for cavo-tricuspid isthmus (CTI) dependent typical atrial flutter (AFL) have traditionally been performed with conventional electrophysiology mapping guided by fluoroscopy. Three-dimensional electroanatomical mapping (EAM) systems have routinely been used to guide ablation of more complex arrhythmias, but in recent years, have been used for simple ablations with the aim of reducing irradiation. High voltage regions in the CTI have been described as a target in order to minimize procedure times, but there is a lack of knowledge regarding the utility of slow conduction zones for this purpose. METHODS: In a prospective cohort of patients undergoing 3D EAM assisted AFL ablation, we evaluated a novel strategy (NS) based on omnipolar vectors, using both wave speed and voltage information to focus radiofrequency (RF) lesions (see figure), and compared with a recent retrospective cohort of patients undergoing voltage-guided ablation (VG). RESULTS: A group of 26 consecutive patients with mean age 68±12 years and 88% male, underwent NS ablation, and were compared to 23 patients undergoing VG ablation, with no differences among patient characteristics. Of the 26 patients in group NS, 16 (53.9%) were successfully ablated targeting only 2 sites, representing the 2 most confluent areas of low wave speed and high voltage. A total of 24 (92.5%) were ablated successfully with targeting all sites of low wave speed. Only a single patient in the NS group required the completion of a classic CTI line. Average fluoroscopy time and radiation dose were lower in the NS group compared to VG group (1.1±2.4 min 19.5±41.7 mGray vs 8.2±10.2 min and 64.4±76.5 mGray, p=0.0014 and p=0.013, respectively). Furthermore, RF time trended towards reduction in the NS group. CONCLUSIONS: A strategy based on targeting only areas of low wave speed is effective, limiting the need to complete a traditional CTI line, and reducing fluoroscopy in patients undergoin CTI ablation. [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207368/ http://dx.doi.org/10.1093/europace/euad122.234 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 11.4 - Treatment
Rodriguez, O R
Zaraket, F Z
Gonzalez, C G
Casteigt, B C
Jimenez, J J
Valles Gras, E
Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
title Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
title_full Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
title_fullStr Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
title_full_unstemmed Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
title_short Wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
title_sort wave speed guided point-by-point cavo-tricuspid isthmus ablation to reduce ablation and fluoroscopy in typical atrial flutter
topic 11.4 - Treatment
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207368/
http://dx.doi.org/10.1093/europace/euad122.234
work_keys_str_mv AT rodriguezor wavespeedguidedpointbypointcavotricuspidisthmusablationtoreduceablationandfluoroscopyintypicalatrialflutter
AT zaraketfz wavespeedguidedpointbypointcavotricuspidisthmusablationtoreduceablationandfluoroscopyintypicalatrialflutter
AT gonzalezcg wavespeedguidedpointbypointcavotricuspidisthmusablationtoreduceablationandfluoroscopyintypicalatrialflutter
AT casteigtbc wavespeedguidedpointbypointcavotricuspidisthmusablationtoreduceablationandfluoroscopyintypicalatrialflutter
AT jimenezjj wavespeedguidedpointbypointcavotricuspidisthmusablationtoreduceablationandfluoroscopyintypicalatrialflutter
AT vallesgrase wavespeedguidedpointbypointcavotricuspidisthmusablationtoreduceablationandfluoroscopyintypicalatrialflutter