Cargando…

Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Other. Main funding source(s): The DEVICE registries were financed by “Stiftung Institut für Herzinfarktforschung (IHF)”, with additional support by grants from Biotronik, Medtronic, and St. Jude Medical. BACKGROUND: Experimental data and early clin...

Descripción completa

Detalles Bibliográficos
Autores principales: Wiedmann, F, Ince, H, Stellbrink, C, Kleemann, T, Eckardt, L, Brachmann, J, Gonska, B D, Kaab, S, Perings, C A, Jung, W, Lugenbiel, P, Hochadel, M, Senges, J, Frey, N, Schmidt, C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207440/
http://dx.doi.org/10.1093/europace/euad122.410
_version_ 1785046454081945600
author Wiedmann, F
Ince, H
Stellbrink, C
Kleemann, T
Eckardt, L
Brachmann, J
Gonska, B D
Kaab, S
Perings, C A
Jung, W
Lugenbiel, P
Hochadel, M
Senges, J
Frey, N
Schmidt, C
author_facet Wiedmann, F
Ince, H
Stellbrink, C
Kleemann, T
Eckardt, L
Brachmann, J
Gonska, B D
Kaab, S
Perings, C A
Jung, W
Lugenbiel, P
Hochadel, M
Senges, J
Frey, N
Schmidt, C
author_sort Wiedmann, F
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Other. Main funding source(s): The DEVICE registries were financed by “Stiftung Institut für Herzinfarktforschung (IHF)”, with additional support by grants from Biotronik, Medtronic, and St. Jude Medical. BACKGROUND: Experimental data and early clinical trials suggested that amiodarone may alter the defibrillation threshold of ICD systems. However, because of its potent antiarrhythmic effect and lack of alternatives, amiodarone is frequently used for antiarrhythmic therapy in ICD or CRT-D patients, leading to the question of whether ICD testing with ventricular fibrillation induction should be repeated in these patients after starting amiodarone. OBJECTIVE: This study was designed to assess the impact of amiodarone therapy on the success of ventricular fibrillation induction tests in this "real life" cohort of ICD recipients of the German DEVICE registry. METHODS: 3,680 patients who underwent ICD implantation, revision, or upgrade in 49 centers participating in the German DEVICE Registry were enrolled 03/2007-02/2014. RESULTS: Intraoperative defibrillation testing was conducted in 2,705 patients receiving only beta-blockes as antiarrhythmic therapy and in 422 patients under betablocker plus amiodarone therapy. With regard to ineffective defibrillation tests, no difference could be described between the two groups (0.6% vs. 0.5%; p=0.77). In a similar fashion 488 patients receiving beta-blockers only and 65 patients under beta-blocker plus amiodarone therapy who were scheduled for postoperative defibrillation testing showed comparable rates of ineffective testing (14.5% vs. 15.4%; p=0.86). CONCLUSIONS: Based on 3,127 intraoperative and 553 postoperative defibrillator testings, our study failed to show a significant association of amiodarone therapy and ineffective defibrillator testings in this "real life" cohort of ICD recipients of the German DEVICE registry. Our results thus underline that, apart from special situations such as right-sided implantation, HCM, extravenous ICD systems, etc., it might not be necessary to perform a DFT test after the start of an amiodarone therapy in ICD patients. [Figure: see text]
format Online
Article
Text
id pubmed-10207440
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102074402023-05-25 Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry Wiedmann, F Ince, H Stellbrink, C Kleemann, T Eckardt, L Brachmann, J Gonska, B D Kaab, S Perings, C A Jung, W Lugenbiel, P Hochadel, M Senges, J Frey, N Schmidt, C Europace 14.2 - Implantable Cardioverter-Defibrillator (ICD) FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Other. Main funding source(s): The DEVICE registries were financed by “Stiftung Institut für Herzinfarktforschung (IHF)”, with additional support by grants from Biotronik, Medtronic, and St. Jude Medical. BACKGROUND: Experimental data and early clinical trials suggested that amiodarone may alter the defibrillation threshold of ICD systems. However, because of its potent antiarrhythmic effect and lack of alternatives, amiodarone is frequently used for antiarrhythmic therapy in ICD or CRT-D patients, leading to the question of whether ICD testing with ventricular fibrillation induction should be repeated in these patients after starting amiodarone. OBJECTIVE: This study was designed to assess the impact of amiodarone therapy on the success of ventricular fibrillation induction tests in this "real life" cohort of ICD recipients of the German DEVICE registry. METHODS: 3,680 patients who underwent ICD implantation, revision, or upgrade in 49 centers participating in the German DEVICE Registry were enrolled 03/2007-02/2014. RESULTS: Intraoperative defibrillation testing was conducted in 2,705 patients receiving only beta-blockes as antiarrhythmic therapy and in 422 patients under betablocker plus amiodarone therapy. With regard to ineffective defibrillation tests, no difference could be described between the two groups (0.6% vs. 0.5%; p=0.77). In a similar fashion 488 patients receiving beta-blockers only and 65 patients under beta-blocker plus amiodarone therapy who were scheduled for postoperative defibrillation testing showed comparable rates of ineffective testing (14.5% vs. 15.4%; p=0.86). CONCLUSIONS: Based on 3,127 intraoperative and 553 postoperative defibrillator testings, our study failed to show a significant association of amiodarone therapy and ineffective defibrillator testings in this "real life" cohort of ICD recipients of the German DEVICE registry. Our results thus underline that, apart from special situations such as right-sided implantation, HCM, extravenous ICD systems, etc., it might not be necessary to perform a DFT test after the start of an amiodarone therapy in ICD patients. [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207440/ http://dx.doi.org/10.1093/europace/euad122.410 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 14.2 - Implantable Cardioverter-Defibrillator (ICD)
Wiedmann, F
Ince, H
Stellbrink, C
Kleemann, T
Eckardt, L
Brachmann, J
Gonska, B D
Kaab, S
Perings, C A
Jung, W
Lugenbiel, P
Hochadel, M
Senges, J
Frey, N
Schmidt, C
Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry
title Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry
title_full Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry
title_fullStr Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry
title_full_unstemmed Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry
title_short Amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after ICD implantation. Insights from the German DEVICE registry
title_sort amiodarone does not significantly affect the success rate of ventricular fibrillation induction tests performed during or after icd implantation. insights from the german device registry
topic 14.2 - Implantable Cardioverter-Defibrillator (ICD)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207440/
http://dx.doi.org/10.1093/europace/euad122.410
work_keys_str_mv AT wiedmannf amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT inceh amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT stellbrinkc amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT kleemannt amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT eckardtl amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT brachmannj amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT gonskabd amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT kaabs amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT peringsca amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT jungw amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT lugenbielp amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT hochadelm amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT sengesj amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT freyn amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry
AT schmidtc amiodaronedoesnotsignificantlyaffectthesuccessrateofventricularfibrillationinductiontestsperformedduringoraftericdimplantationinsightsfromthegermandeviceregistry