Cargando…

Long-term safety and efficacy of leadless pacemakers in the Dutch cohort

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Leadless pacemakers (LPs) were designed to circumvent pocket- and lead-related pacemaker complications. Up to two years after implantation, adequate real-world safety and efficacy have been demonstrated. Because the duration of pac...

Descripción completa

Detalles Bibliográficos
Autores principales: Breeman, K T N, Oosterwerff, E F J, De Graaf, M A, Juffer, A, Saleem-Talib, S, Maass, A H, Wilde, A A M, Boersma, L V A, Remanna, H, Van Dijk, V F, Van Erven, L, Delnoy, P P H M, Tjong, F V Y, Knops, R E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207468/
http://dx.doi.org/10.1093/europace/euad122.406
Descripción
Sumario:FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Leadless pacemakers (LPs) were designed to circumvent pocket- and lead-related pacemaker complications. Up to two years after implantation, adequate real-world safety and efficacy have been demonstrated. Because the duration of pacemaker therapy is well over two years, longer-term data is warranted for the net clinical benefit of leadless pacing. OBJECTIVE: Our aim was to evaluate the safety and efficacy of LP therapy on the long-term in a real-world cohort. METHODS: In this retrospective cohort study, all consecutive patients were included with a first LP implantation (Nanostim LP or Micra VR LP) from December 21, 2012 to December 13, 2016 in 6 Dutch high-volume centers. The primary safety endpoint was the rate of procedure- or device-related major complications at 5-year follow-up. Analyses were performed with and without the Nanostim battery advisory-related complications. The efficacy is described as pacing threshold, impedance and R-wave amplitude over time; changes in these parameters were assessed using mixed models. RESULTS: 179 patients were included (117 [65%] male, mean age 79±9 years), of whom 93 (52%) with a Nanostim and 86 (48%) with a Micra LP. Mean follow-up duration was 45±25 months. A total of 46 major complications occurred, of which 8 not advisory-related. The 5-year major complication rate without advisory-related complications was 4.5% (Figure, A). Including advisory-related complications, the 5-year major complication rate was 30.5%. Not advisory-related complications included dislocations (n=3, of which 2 periprocedurally), pericardial effusion (n=1), groin bleeding (n=1), loss-of-capture (n=2) and pacemaker syndrome (n=1). Reinterventions were required in 7/8 (88%), only prolonged hospitalization in 1 (12%; the groin bleeding), and surgery in none. All 8 occurred within 90 days after implantation. Pacing threshold was stable over time (p=0.53), R-wave amplitude increased (p=0.002), and impedance decreased (p<0.001) (Figure, B). CONCLUSION: The long-term major complication rate excluding advisory-related complications was low. Especially few complications occurred after the acute phase, which may be a specific benefit of LP therapy. The performance was adequate with a stable pacing threshold over time, whereas in transvenous pacemakers usually a gradually increasing threshold is seen. These findings confirm previous safety and efficacy results and are promising for longer-term data on leadless pacing. [Figure: see text]