Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Private company. Main funding source(s): Heailum Medical Inc. BACKGROUND: Utilization of collimated acoustic energy transition as an ablation energy source has the advantage of propagation through blood with negligible absorption. This allows delive...

Descripción completa

Detalles Bibliográficos
Autores principales: Leshem-Rubinow, E, Weizman, A, Sela, R, Margolis, G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207482/
http://dx.doi.org/10.1093/europace/euad122.747
_version_ 1785046464895909888
author Leshem-Rubinow, E
Weizman, A
Sela, R
Margolis, G
author_facet Leshem-Rubinow, E
Weizman, A
Sela, R
Margolis, G
author_sort Leshem-Rubinow, E
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Private company. Main funding source(s): Heailum Medical Inc. BACKGROUND: Utilization of collimated acoustic energy transition as an ablation energy source has the advantage of propagation through blood with negligible absorption. This allows delivery of non-contact, directional and precise ablation lesions to cardiac tissue. In addition, with dual mode ultrasound technology real-time monitoring of the tissue is possible during ablation. AIM: To evaluate a proprietary ultrasound-based ablation system in swine and define the characteristics of the isolated ablation lesions and lines performed in-vivo. METHODS: In female large white swines, bilateral thigh muscle prep ablations were performed using different time and energy ablation parameters while tip to tissue distance measured with the imaging B-mode and set to 10mm. Lesions were analysed for maximal depth and width. Additional assessment for contiguous linear ablation was performed in the thigh muscle, SVC and within the coronary sinus with the transducer rotated to the endocardial direction. Tissue was fixed in formalin and gross pathological examination with lesion measurement was performed. RESULTS: 36 distinct ablation lesions were performed in the thigh prep model. No steam pops were observed for any of the lesions. Mean necrotic lesion depth was 5.35 ± 1.5mm, with increased time with greater influence on dimensions compared to small changes in energy delivered (Figure 1). Reversible damage influenced additional 29% of tissue depth, while 55% additional tissue width was reversible. Linear ablation performed at 2.5mm inter-lesion distance showed contiguous lines, with transmural effect in both SVC and coronary sinus. CONCLUSIONS: A novel ultrasound based catheter ablation has the ability for non-contact effective ablation in cardiac tissue with directional and tailored energy selection to achieve transmural atrial ablation. Additional in-vivo experimentation will allow refinement of this tool for both isolated lesions and linear ablation while enabling tissue visualization. [Figure: see text]
format Online
Article
Text
id pubmed-10207482
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102074822023-05-25 Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound Leshem-Rubinow, E Weizman, A Sela, R Margolis, G Europace 9.4.4 - Catheter Ablation of Arrhythmias FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Private company. Main funding source(s): Heailum Medical Inc. BACKGROUND: Utilization of collimated acoustic energy transition as an ablation energy source has the advantage of propagation through blood with negligible absorption. This allows delivery of non-contact, directional and precise ablation lesions to cardiac tissue. In addition, with dual mode ultrasound technology real-time monitoring of the tissue is possible during ablation. AIM: To evaluate a proprietary ultrasound-based ablation system in swine and define the characteristics of the isolated ablation lesions and lines performed in-vivo. METHODS: In female large white swines, bilateral thigh muscle prep ablations were performed using different time and energy ablation parameters while tip to tissue distance measured with the imaging B-mode and set to 10mm. Lesions were analysed for maximal depth and width. Additional assessment for contiguous linear ablation was performed in the thigh muscle, SVC and within the coronary sinus with the transducer rotated to the endocardial direction. Tissue was fixed in formalin and gross pathological examination with lesion measurement was performed. RESULTS: 36 distinct ablation lesions were performed in the thigh prep model. No steam pops were observed for any of the lesions. Mean necrotic lesion depth was 5.35 ± 1.5mm, with increased time with greater influence on dimensions compared to small changes in energy delivered (Figure 1). Reversible damage influenced additional 29% of tissue depth, while 55% additional tissue width was reversible. Linear ablation performed at 2.5mm inter-lesion distance showed contiguous lines, with transmural effect in both SVC and coronary sinus. CONCLUSIONS: A novel ultrasound based catheter ablation has the ability for non-contact effective ablation in cardiac tissue with directional and tailored energy selection to achieve transmural atrial ablation. Additional in-vivo experimentation will allow refinement of this tool for both isolated lesions and linear ablation while enabling tissue visualization. [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207482/ http://dx.doi.org/10.1093/europace/euad122.747 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.4.4 - Catheter Ablation of Arrhythmias
Leshem-Rubinow, E
Weizman, A
Sela, R
Margolis, G
Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
title Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
title_full Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
title_fullStr Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
title_full_unstemmed Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
title_short Feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
title_sort feasibility and proof of concept of a proprietary non-contact ablation system with low intensity collimated ultrasound
topic 9.4.4 - Catheter Ablation of Arrhythmias
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207482/
http://dx.doi.org/10.1093/europace/euad122.747
work_keys_str_mv AT leshemrubinowe feasibilityandproofofconceptofaproprietarynoncontactablationsystemwithlowintensitycollimatedultrasound
AT weizmana feasibilityandproofofconceptofaproprietarynoncontactablationsystemwithlowintensitycollimatedultrasound
AT selar feasibilityandproofofconceptofaproprietarynoncontactablationsystemwithlowintensitycollimatedultrasound
AT margolisg feasibilityandproofofconceptofaproprietarynoncontactablationsystemwithlowintensitycollimatedultrasound