Robustness of electrocardiographic imaging in the presence of electrical noise

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Other. Main funding source(s): Ministerio de Ciencia, Innovación y Universidades; Generalitat Valenciana BACKGROUND: Electrocardiographic Imaging (ECGI) allows evaluating the cardiac substrate non-invasively. However, the inverse solution is strongl...

Descripción completa

Detalles Bibliográficos
Autores principales: Molero, R, Martinez-Perez, M, Reventos-Presmanes, J, Mont, L, Climent, A M, Guillem, M S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207498/
http://dx.doi.org/10.1093/europace/euad122.640
_version_ 1785046468723212288
author Molero, R
Martinez-Perez, M
Reventos-Presmanes, J
Mont, L
Climent, A M
Guillem, M S
author_facet Molero, R
Martinez-Perez, M
Reventos-Presmanes, J
Mont, L
Climent, A M
Guillem, M S
author_sort Molero, R
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Other. Main funding source(s): Ministerio de Ciencia, Innovación y Universidades; Generalitat Valenciana BACKGROUND: Electrocardiographic Imaging (ECGI) allows evaluating the cardiac substrate non-invasively. However, the inverse solution is strongly dependent on the noise of the body surface signals. Zero-order Tikhonov regularization together with L-curve optimization, widely used in ECGI studies, allows minimizing the sources of noise to find an optimal solution. OBJECTIVE: Evaluate the effect of electrical and noise on the L-curve optimization in computer simulations of atrial activity and in the physiological interpretation of the inverse solution. METHODS: Five atrial simulations of regular rhythms (3 atrial flutter and 2 sinus rhythm) were used for computing the ECGI with five signal-to-noise ratios (SNR) (from 3dB to 40dB). ECGI was computed by zero-order Tikhonov regularization and L-curve optimization. The regularization parameter (λ) and the shape of the curve were analysed. Electrical noise was added to signals from an atrial flutter patient to study the effect on real ECGI signals. Local activation time (LAT) maps were obtained to evaluate the quality of the ECGI in front of noise. Correlation coefficient (CC) of LAT maps was computed between simulated electrograms and ECGIs. RESULTS: The level of noise was found to be correlated with the optimal regularization parameter (λ), (SNR 3dB, λ>10-6, SNR 40dB, λ<10-9). LAT maps for the optimal λ and higher were able to find relevant information about the simulation and patient independently on the SNR (CC3dB-EGM = 0.66±0.1, CC40dB-EGM = 0.76±0.1). Similar behaviour was observed in real atrial flutter signals (CC3dB-Ref = 0.83, CC10dB-Ref = 0.93). LAT maps from the atrial flutter were able to accurately locate the reentry circuit, as found in the electroanatomical map independently on the SNR. CONCLUSION: LAT maps derived from ECGI are robust against the presence of noise. Although the reconstructed potentials are smoother with increasing levels of noise, LAT maps with and without noise show a good correlation thanks to an increased regularization. Figure 1. A. Local activation times (LAT) map of a reference electrogram (EGM) from a computer simulation of sinus rhythm in the atria. B. Electrocardiographic imaging maps (ECGI) obtained from the simulation A for different levels of electrical noise and regularization parameters. C. Example of LAT map obtained with ECGI and the endocardial map of a typical atrial flutter together with LAT maps with increased electrical noise but comparable results (CC > 0.83). [Figure: see text]
format Online
Article
Text
id pubmed-10207498
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102074982023-05-25 Robustness of electrocardiographic imaging in the presence of electrical noise Molero, R Martinez-Perez, M Reventos-Presmanes, J Mont, L Climent, A M Guillem, M S Europace 9.3.7 - Noninvasive Diagnostic Methods FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Other. Main funding source(s): Ministerio de Ciencia, Innovación y Universidades; Generalitat Valenciana BACKGROUND: Electrocardiographic Imaging (ECGI) allows evaluating the cardiac substrate non-invasively. However, the inverse solution is strongly dependent on the noise of the body surface signals. Zero-order Tikhonov regularization together with L-curve optimization, widely used in ECGI studies, allows minimizing the sources of noise to find an optimal solution. OBJECTIVE: Evaluate the effect of electrical and noise on the L-curve optimization in computer simulations of atrial activity and in the physiological interpretation of the inverse solution. METHODS: Five atrial simulations of regular rhythms (3 atrial flutter and 2 sinus rhythm) were used for computing the ECGI with five signal-to-noise ratios (SNR) (from 3dB to 40dB). ECGI was computed by zero-order Tikhonov regularization and L-curve optimization. The regularization parameter (λ) and the shape of the curve were analysed. Electrical noise was added to signals from an atrial flutter patient to study the effect on real ECGI signals. Local activation time (LAT) maps were obtained to evaluate the quality of the ECGI in front of noise. Correlation coefficient (CC) of LAT maps was computed between simulated electrograms and ECGIs. RESULTS: The level of noise was found to be correlated with the optimal regularization parameter (λ), (SNR 3dB, λ>10-6, SNR 40dB, λ<10-9). LAT maps for the optimal λ and higher were able to find relevant information about the simulation and patient independently on the SNR (CC3dB-EGM = 0.66±0.1, CC40dB-EGM = 0.76±0.1). Similar behaviour was observed in real atrial flutter signals (CC3dB-Ref = 0.83, CC10dB-Ref = 0.93). LAT maps from the atrial flutter were able to accurately locate the reentry circuit, as found in the electroanatomical map independently on the SNR. CONCLUSION: LAT maps derived from ECGI are robust against the presence of noise. Although the reconstructed potentials are smoother with increasing levels of noise, LAT maps with and without noise show a good correlation thanks to an increased regularization. Figure 1. A. Local activation times (LAT) map of a reference electrogram (EGM) from a computer simulation of sinus rhythm in the atria. B. Electrocardiographic imaging maps (ECGI) obtained from the simulation A for different levels of electrical noise and regularization parameters. C. Example of LAT map obtained with ECGI and the endocardial map of a typical atrial flutter together with LAT maps with increased electrical noise but comparable results (CC > 0.83). [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207498/ http://dx.doi.org/10.1093/europace/euad122.640 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.3.7 - Noninvasive Diagnostic Methods
Molero, R
Martinez-Perez, M
Reventos-Presmanes, J
Mont, L
Climent, A M
Guillem, M S
Robustness of electrocardiographic imaging in the presence of electrical noise
title Robustness of electrocardiographic imaging in the presence of electrical noise
title_full Robustness of electrocardiographic imaging in the presence of electrical noise
title_fullStr Robustness of electrocardiographic imaging in the presence of electrical noise
title_full_unstemmed Robustness of electrocardiographic imaging in the presence of electrical noise
title_short Robustness of electrocardiographic imaging in the presence of electrical noise
title_sort robustness of electrocardiographic imaging in the presence of electrical noise
topic 9.3.7 - Noninvasive Diagnostic Methods
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207498/
http://dx.doi.org/10.1093/europace/euad122.640
work_keys_str_mv AT moleror robustnessofelectrocardiographicimaginginthepresenceofelectricalnoise
AT martinezperezm robustnessofelectrocardiographicimaginginthepresenceofelectricalnoise
AT reventospresmanesj robustnessofelectrocardiographicimaginginthepresenceofelectricalnoise
AT montl robustnessofelectrocardiographicimaginginthepresenceofelectricalnoise
AT climentam robustnessofelectrocardiographicimaginginthepresenceofelectricalnoise
AT guillemms robustnessofelectrocardiographicimaginginthepresenceofelectricalnoise