Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (SICD) is effective therapy for sudden cardiac death prevention. The condition for implantation is an electrocardiographic screening test before procedure (ECG-s). Patients wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Lewandowski, M, Syska, P, Kowalik, I
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207667/
http://dx.doi.org/10.1093/europace/euad122.423
_version_ 1785046507717656576
author Lewandowski, M
Syska, P
Kowalik, I
author_facet Lewandowski, M
Syska, P
Kowalik, I
author_sort Lewandowski, M
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (SICD) is effective therapy for sudden cardiac death prevention. The condition for implantation is an electrocardiographic screening test before procedure (ECG-s). Patients who don’t pass are regarded to be at risk of inappropriate detection of tachyarrhythmias with inappropriate interventions. A patient is considered suitable for implant if at least one surface ECG lead (sense vector) is acceptable for all tested postures. OBJECTIVE: The aim of the study was to identify the incidence of failure, the predicting factors and clinical importance of extended ECG-s with right sided lead position and lying on the left and right side of the body. METHODS: ECG-s to determine suitability for SICD is based and performed using a manufacturer –specific measurement tool. We performed this test in 75 consecutive pts with indication for SICD therapy on the basis of standard manufacturer protocol(lead at the left sternum border: sitting, standing and lying position), and extended for right sternal lead location and two additional body position: lying on the left and right side (10 position for each individual). We analyzed: age, gender, body mass index(BMI), heart rate, heart rhythm(sinus/atrial fibrillation), QRS duration, PR interval, corrected QT interval(QTc), echocardiography parameters, etiology. RESULTS: ECG-s failure occurred in 6/75(8%) of patients. Screening results: 1 vector failure rate with the standard device and lead positions: primary(P) 12%, seconadary(S) 17%, alternative(A) 40%, P vs. A and S vs. A p<0,001. Testing with an electrode positioned on the right sternum border- 1 vector failure: (P) 10%,seconadary(S) 17%, alternative(A) 48%, P vs. A and S vs. A p<0,001. In case of failure on left side 50%, 14% and 6% of pts passed the test with the right sided lead position for P, S and A vector respectively, p<0.001. Identified factors predicting ESG-s passing vs. failure included: QTc interval 445,32±35,4 vs. 480,6±37,6 ms for any vector(p=0,034), BMI:26,7±4,7 vs. 29,9±4,7 for vector A( p=0,008 ), EF: 43,3±20,1 vs. 34,0±16,2 for vector A( p=0,027). Sense vector failure rate with the left sternal lead location lying on the left and right side of the body was concordant with the rate lying on the back, p=0,05. For the right parasternal lead location the rate failure was lower lying on the right side for all sense vectors: P, S and A(p=0,045; 0,083 and 0,020) respectively. CONCLUSIONS: ECG screening failure rate for SICD is comparable with previous reports. The right sternal lead location screening is effective and enables important clinical findings before implantation and in case of lead reposition( defibrillation threshold test failure) during procedure. We recommend to screen routinely on both sternum borders. Some additional body position testing: lying on the left and right side of the body, mimicking sleeping/rest could be an important element to determine eligibility for SICD. [Figure: see text] [Figure: see text]
format Online
Article
Text
id pubmed-10207667
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102076672023-05-25 Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator Lewandowski, M Syska, P Kowalik, I Europace 14.2 - Implantable Cardioverter-Defibrillator (ICD) FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (SICD) is effective therapy for sudden cardiac death prevention. The condition for implantation is an electrocardiographic screening test before procedure (ECG-s). Patients who don’t pass are regarded to be at risk of inappropriate detection of tachyarrhythmias with inappropriate interventions. A patient is considered suitable for implant if at least one surface ECG lead (sense vector) is acceptable for all tested postures. OBJECTIVE: The aim of the study was to identify the incidence of failure, the predicting factors and clinical importance of extended ECG-s with right sided lead position and lying on the left and right side of the body. METHODS: ECG-s to determine suitability for SICD is based and performed using a manufacturer –specific measurement tool. We performed this test in 75 consecutive pts with indication for SICD therapy on the basis of standard manufacturer protocol(lead at the left sternum border: sitting, standing and lying position), and extended for right sternal lead location and two additional body position: lying on the left and right side (10 position for each individual). We analyzed: age, gender, body mass index(BMI), heart rate, heart rhythm(sinus/atrial fibrillation), QRS duration, PR interval, corrected QT interval(QTc), echocardiography parameters, etiology. RESULTS: ECG-s failure occurred in 6/75(8%) of patients. Screening results: 1 vector failure rate with the standard device and lead positions: primary(P) 12%, seconadary(S) 17%, alternative(A) 40%, P vs. A and S vs. A p<0,001. Testing with an electrode positioned on the right sternum border- 1 vector failure: (P) 10%,seconadary(S) 17%, alternative(A) 48%, P vs. A and S vs. A p<0,001. In case of failure on left side 50%, 14% and 6% of pts passed the test with the right sided lead position for P, S and A vector respectively, p<0.001. Identified factors predicting ESG-s passing vs. failure included: QTc interval 445,32±35,4 vs. 480,6±37,6 ms for any vector(p=0,034), BMI:26,7±4,7 vs. 29,9±4,7 for vector A( p=0,008 ), EF: 43,3±20,1 vs. 34,0±16,2 for vector A( p=0,027). Sense vector failure rate with the left sternal lead location lying on the left and right side of the body was concordant with the rate lying on the back, p=0,05. For the right parasternal lead location the rate failure was lower lying on the right side for all sense vectors: P, S and A(p=0,045; 0,083 and 0,020) respectively. CONCLUSIONS: ECG screening failure rate for SICD is comparable with previous reports. The right sternal lead location screening is effective and enables important clinical findings before implantation and in case of lead reposition( defibrillation threshold test failure) during procedure. We recommend to screen routinely on both sternum borders. Some additional body position testing: lying on the left and right side of the body, mimicking sleeping/rest could be an important element to determine eligibility for SICD. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207667/ http://dx.doi.org/10.1093/europace/euad122.423 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 14.2 - Implantable Cardioverter-Defibrillator (ICD)
Lewandowski, M
Syska, P
Kowalik, I
Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
title Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
title_full Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
title_fullStr Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
title_full_unstemmed Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
title_short Standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
title_sort standard and extended electrocardiographic screening for the subcutaneous implantable cardioverter-defibrillator
topic 14.2 - Implantable Cardioverter-Defibrillator (ICD)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207667/
http://dx.doi.org/10.1093/europace/euad122.423
work_keys_str_mv AT lewandowskim standardandextendedelectrocardiographicscreeningforthesubcutaneousimplantablecardioverterdefibrillator
AT syskap standardandextendedelectrocardiographicscreeningforthesubcutaneousimplantablecardioverterdefibrillator
AT kowaliki standardandextendedelectrocardiographicscreeningforthesubcutaneousimplantablecardioverterdefibrillator