Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Previous studies have demonstrated that cardiac biomarkers elevate after both cryoballoon (CB) and radiofrequency atrial fibrillation (AF) ablation, depending on the amount of energy delivered and the site of ablation. To date no c...

Descripción completa

Detalles Bibliográficos
Autores principales: Majocchi, B, Moltrasio, M, Fassini, G, Tundo, F, Riva, S, Vettor, G, Sicuso, R, Bianchini, L, Malacrida, M, Tondo, C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207679/
http://dx.doi.org/10.1093/europace/euad122.739
_version_ 1785046510672543744
author Majocchi, B
Moltrasio, M
Fassini, G
Tundo, F
Riva, S
Vettor, G
Sicuso, R
Bianchini, L
Malacrida, M
Tondo, C
author_facet Majocchi, B
Moltrasio, M
Fassini, G
Tundo, F
Riva, S
Vettor, G
Sicuso, R
Bianchini, L
Malacrida, M
Tondo, C
author_sort Majocchi, B
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Previous studies have demonstrated that cardiac biomarkers elevate after both cryoballoon (CB) and radiofrequency atrial fibrillation (AF) ablation, depending on the amount of energy delivered and the site of ablation. To date no comparison has been made between these thermal energy source and a novel non-thermal pulsed-field ablation (PFA) technology based on cells electroporation. PURPOSE: Our analysis aims to compare acute myocardial injury through cardiac troponin I variation after pulmonary vein isolation (PVI) performed with different technologies (PFA vs CB). METHODS: All consecutive patients undergoing paroxysmal AF ablation with CB and PFA at our center from July to November 2022 were included. Protocol-directed cryoablation (CBA) was delivered for 180 sec or 240 sec according to operator’s preference for isolation achieved in ≤60 sec, or 240 sec if isolation occurred >60 sec or when time to isolation was not available. A standard PFA protocol-directed PVI was applied using 2kV with eight applications per vein (four applications each in the basket and flower poses). The ablation endpoint was PVI as assessed by entrance and exit block. Pre- and post-procedure samples of cardiac troponin I (CTpI) were collected before CBA/PFA and at 24h after ablation. Only patients with normal baseline values for myocardial injury were included. RESULTS: A total of 71 patients met inclusion criteria and were included in this analysis. The CBA group consists of 50 (70%) patients and the PFA group comprises 21 (30%) patients. The number of CBA applications to reach PVI was 5.0±1.4 and the number of PFA applications to achieve PVI was 32±4. All (100%) patients were in sinus rhythm at the time of the procedure. Evaluating the kinetic of CTpI, baseline values were homogeneous between CBA and PFA groups (p=0.979) whereas CTpI values significantly rose from baseline (7±2 ng/L) to 24h (8979±3691 ng/L, p<0.0001) and were significantly different between groups after CBA/PFA (8148±3311 ng/L for CBA vs 11900±7143 ng/L for PFA, p=0.0056). PVI was achieved in all patients (100%) using only CB or PFA. No major procedure-related adverse events were reported. CONCLUSION: Our preliminary results showed that cardiac troponin I enzyme level increased after PVI by means of both cryoballoon and pulsed-field ablation and were higher after cellular electroporation by PFA than cryoablation.
format Online
Article
Text
id pubmed-10207679
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102076792023-05-25 Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy Majocchi, B Moltrasio, M Fassini, G Tundo, F Riva, S Vettor, G Sicuso, R Bianchini, L Malacrida, M Tondo, C Europace 9.4.4 - Catheter Ablation of Arrhythmias FUNDING ACKNOWLEDGEMENTS: Type of funding sources: None. BACKGROUND: Previous studies have demonstrated that cardiac biomarkers elevate after both cryoballoon (CB) and radiofrequency atrial fibrillation (AF) ablation, depending on the amount of energy delivered and the site of ablation. To date no comparison has been made between these thermal energy source and a novel non-thermal pulsed-field ablation (PFA) technology based on cells electroporation. PURPOSE: Our analysis aims to compare acute myocardial injury through cardiac troponin I variation after pulmonary vein isolation (PVI) performed with different technologies (PFA vs CB). METHODS: All consecutive patients undergoing paroxysmal AF ablation with CB and PFA at our center from July to November 2022 were included. Protocol-directed cryoablation (CBA) was delivered for 180 sec or 240 sec according to operator’s preference for isolation achieved in ≤60 sec, or 240 sec if isolation occurred >60 sec or when time to isolation was not available. A standard PFA protocol-directed PVI was applied using 2kV with eight applications per vein (four applications each in the basket and flower poses). The ablation endpoint was PVI as assessed by entrance and exit block. Pre- and post-procedure samples of cardiac troponin I (CTpI) were collected before CBA/PFA and at 24h after ablation. Only patients with normal baseline values for myocardial injury were included. RESULTS: A total of 71 patients met inclusion criteria and were included in this analysis. The CBA group consists of 50 (70%) patients and the PFA group comprises 21 (30%) patients. The number of CBA applications to reach PVI was 5.0±1.4 and the number of PFA applications to achieve PVI was 32±4. All (100%) patients were in sinus rhythm at the time of the procedure. Evaluating the kinetic of CTpI, baseline values were homogeneous between CBA and PFA groups (p=0.979) whereas CTpI values significantly rose from baseline (7±2 ng/L) to 24h (8979±3691 ng/L, p<0.0001) and were significantly different between groups after CBA/PFA (8148±3311 ng/L for CBA vs 11900±7143 ng/L for PFA, p=0.0056). PVI was achieved in all patients (100%) using only CB or PFA. No major procedure-related adverse events were reported. CONCLUSION: Our preliminary results showed that cardiac troponin I enzyme level increased after PVI by means of both cryoballoon and pulsed-field ablation and were higher after cellular electroporation by PFA than cryoablation. Oxford University Press 2023-05-24 /pmc/articles/PMC10207679/ http://dx.doi.org/10.1093/europace/euad122.739 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.4.4 - Catheter Ablation of Arrhythmias
Majocchi, B
Moltrasio, M
Fassini, G
Tundo, F
Riva, S
Vettor, G
Sicuso, R
Bianchini, L
Malacrida, M
Tondo, C
Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
title Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
title_full Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
title_fullStr Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
title_full_unstemmed Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
title_short Cardiac Troponin I kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
title_sort cardiac troponin i kinetic after pulmonary vein isolation for atrial fibrillation ablation with pulsed-field ablation and cryo-energy
topic 9.4.4 - Catheter Ablation of Arrhythmias
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207679/
http://dx.doi.org/10.1093/europace/euad122.739
work_keys_str_mv AT majocchib cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT moltrasiom cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT fassinig cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT tundof cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT rivas cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT vettorg cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT sicusor cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT bianchinil cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT malacridam cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy
AT tondoc cardiactroponinikineticafterpulmonaryveinisolationforatrialfibrillationablationwithpulsedfieldablationandcryoenergy