Cargando…

Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public Institution(s). Main funding source(s): Research reported in this abstract was supported by the National Heart, Lung, And Blood Institute of the National Institutes of Health under Award Number R44HL158375 (the content is solely the responsib...

Descripción completa

Detalles Bibliográficos
Autores principales: Mercado Montoya, M, Gomez Bustamante, T, Kulstad, E, Berjano, E, Mickelsen, S, Hernandez Arango, P, Gonzalez Suarez, A, Schieber, J, Daniels, J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207689/
http://dx.doi.org/10.1093/europace/euad122.717
_version_ 1785046512835756032
author Mercado Montoya, M
Gomez Bustamante, T
Kulstad, E
Berjano, E
Mickelsen, S
Hernandez Arango, P
Gonzalez Suarez, A
Schieber, J
Daniels, J
author_facet Mercado Montoya, M
Gomez Bustamante, T
Kulstad, E
Berjano, E
Mickelsen, S
Hernandez Arango, P
Gonzalez Suarez, A
Schieber, J
Daniels, J
author_sort Mercado Montoya, M
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public Institution(s). Main funding source(s): Research reported in this abstract was supported by the National Heart, Lung, And Blood Institute of the National Institutes of Health under Award Number R44HL158375 (the content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health). BACKGROUND: Placing lesions at the same point (stacking lesions) in the left atrium during radiofrequency (RF) ablation can increase the risk of collateral injury. The use of active esophageal cooling has been shown to significantly reduce the risk of thermal injury to the esophagus, but stacking of lesions may overcome these protective effects. Longer pauses between lesions may reduce this risk, but the effect of very short pauses has not been previously quantified. PURPOSE: To examine the impact of ultra-short pauses between stacked lesions with and without active esophageal cooling. METHODS: Using a computational model of the left atrium, we measured the effect of RF ablation in the left atrium on injury formation in the esophagus. Models with and without active esophageal cooling, using a dedicated esophageal cooling device, were created. Using a power of 50 W for 10 s, with up to 3 sequential lesions placed in the same location, we used the Arrhenius equation to quantify the fraction of damage (FOD) in the esophageal wall. The time between lesions was set to as short as 1 s, and results were compared to prior studies using longer pauses of up to 20 s. To account for thermal latency, measures of esophageal damage were taken both immediately after RF ablation, and again 90 s afterwards. RESULTS: With active cooling in place, esophageal injury was eliminated with active esophageal cooling after the first lesion placement, but reached 21% transmurality without cooling. Lesion transmurality increased after each lesion due to thermal latency, but active esophageal cooling prevented this effect when only one lesion was placed. Subsequent lesions resulted in esophageal injury when placed in the same location. After 3 lesions with 1 s pauses between each, esophageal injury transmurality reached 91% without cooling in place, and 22% with active cooling in place (Figure 1). In contrast, analysis of the intended lesions in the atrial wall demonstrated minimal effects from cooling (Figure 2). CONCLUSIONS: Active esophageal cooling significantly reduces esophageal injury from RF ablation, but placing additional lesions at the same point can overcome the heat extraction capacity of a dedicated cooling device. Decreased time between lesions exacerbates this risk, with an ultra-short pause of one second posing the greatest risk. [Figure: see text] [Figure: see text]
format Online
Article
Text
id pubmed-10207689
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102076892023-05-25 Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling Mercado Montoya, M Gomez Bustamante, T Kulstad, E Berjano, E Mickelsen, S Hernandez Arango, P Gonzalez Suarez, A Schieber, J Daniels, J Europace 9.4.4 - Catheter Ablation of Arrhythmias FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Public Institution(s). Main funding source(s): Research reported in this abstract was supported by the National Heart, Lung, And Blood Institute of the National Institutes of Health under Award Number R44HL158375 (the content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health). BACKGROUND: Placing lesions at the same point (stacking lesions) in the left atrium during radiofrequency (RF) ablation can increase the risk of collateral injury. The use of active esophageal cooling has been shown to significantly reduce the risk of thermal injury to the esophagus, but stacking of lesions may overcome these protective effects. Longer pauses between lesions may reduce this risk, but the effect of very short pauses has not been previously quantified. PURPOSE: To examine the impact of ultra-short pauses between stacked lesions with and without active esophageal cooling. METHODS: Using a computational model of the left atrium, we measured the effect of RF ablation in the left atrium on injury formation in the esophagus. Models with and without active esophageal cooling, using a dedicated esophageal cooling device, were created. Using a power of 50 W for 10 s, with up to 3 sequential lesions placed in the same location, we used the Arrhenius equation to quantify the fraction of damage (FOD) in the esophageal wall. The time between lesions was set to as short as 1 s, and results were compared to prior studies using longer pauses of up to 20 s. To account for thermal latency, measures of esophageal damage were taken both immediately after RF ablation, and again 90 s afterwards. RESULTS: With active cooling in place, esophageal injury was eliminated with active esophageal cooling after the first lesion placement, but reached 21% transmurality without cooling. Lesion transmurality increased after each lesion due to thermal latency, but active esophageal cooling prevented this effect when only one lesion was placed. Subsequent lesions resulted in esophageal injury when placed in the same location. After 3 lesions with 1 s pauses between each, esophageal injury transmurality reached 91% without cooling in place, and 22% with active cooling in place (Figure 1). In contrast, analysis of the intended lesions in the atrial wall demonstrated minimal effects from cooling (Figure 2). CONCLUSIONS: Active esophageal cooling significantly reduces esophageal injury from RF ablation, but placing additional lesions at the same point can overcome the heat extraction capacity of a dedicated cooling device. Decreased time between lesions exacerbates this risk, with an ultra-short pause of one second posing the greatest risk. [Figure: see text] [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207689/ http://dx.doi.org/10.1093/europace/euad122.717 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.4.4 - Catheter Ablation of Arrhythmias
Mercado Montoya, M
Gomez Bustamante, T
Kulstad, E
Berjano, E
Mickelsen, S
Hernandez Arango, P
Gonzalez Suarez, A
Schieber, J
Daniels, J
Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
title Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
title_full Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
title_fullStr Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
title_full_unstemmed Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
title_short Impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
title_sort impact of ultra-short pauses between stacked lesions with and without active esophageal cooling
topic 9.4.4 - Catheter Ablation of Arrhythmias
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207689/
http://dx.doi.org/10.1093/europace/euad122.717
work_keys_str_mv AT mercadomontoyam impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT gomezbustamantet impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT kulstade impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT berjanoe impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT mickelsens impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT hernandezarangop impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT gonzalezsuareza impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT schieberj impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling
AT danielsj impactofultrashortpausesbetweenstackedlesionswithandwithoutactiveesophagealcooling