Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology

FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Private company. Main funding source(s): XSpline S.p.a. AIM: Noninvasive electrocardiographic mapping systems may require multichannel (150-250) ECG body surface recordings which is a huge limitation for the adoption into clinical practice. However,...

Descripción completa

Detalles Bibliográficos
Autores principales: Chmelevsky, M, Zubarev, S, Khamzin, S, Dokuchaev, A, Bazhutina, A, Sinitca, A, Budanova, M, Auricchio, A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207848/
http://dx.doi.org/10.1093/europace/euad122.647
_version_ 1785046544202858496
author Chmelevsky, M
Zubarev, S
Khamzin, S
Dokuchaev, A
Bazhutina, A
Sinitca, A
Budanova, M
Auricchio, A
author_facet Chmelevsky, M
Zubarev, S
Khamzin, S
Dokuchaev, A
Bazhutina, A
Sinitca, A
Budanova, M
Auricchio, A
author_sort Chmelevsky, M
collection PubMed
description FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Private company. Main funding source(s): XSpline S.p.a. AIM: Noninvasive electrocardiographic mapping systems may require multichannel (150-250) ECG body surface recordings which is a huge limitation for the adoption into clinical practice. However, most of the currently available noninvasive mapping systems accurately represent epicardial activation. Over the last few years, various technical solutions have been implemented to increase the accuracy of ECG forward-inverse calculations including machine learning algorithms. We developed a novel 12-lead ECG-based, fully automated system for noninvasive full transmural (epi-endocardial) mapping. The aim of this study was to evaluate accuracy of this system in heart failure patients with typical LBBB. METHODS: Eight consecutive patients (median age: 65; 25-75% range 59-64; 5 male) with typical LBBB QRS morphology (QRS duration 146–224 ms), scheduled for CRT implantation underwent a cardiac CT scan and 12-lead ECG recording, followed by detailed bi-ventricular endocardial electroanatomical contact mapping (EAM). A median of 258 (181-576) local electrograms in LV and 86 (70-139) in RV were collected during EAM. Cardiac CT data were semiautomatically processed using a Unet-like neural network to obtain meshes containing the heart (each chamber with both endocardial and epicardial contour as well as coronary sinus and its branches), lungs and torso using different segmentation module. Noninvasive epi-endocardial activation maps were calculated using state-of-the-art mathematical models including machine learning methods. These data were compared with EAM from the invasive mapping system using Spearman correlation (r), mean absolute error (MAE) and relative distance metrics. RESULTS: All early and latest activation patterns were correctly identified (see figure). The average correlation (r) of endocardial activation maps was 0.92 for all cases (min-max: 0.82-0.96). MAE was rather small (9-15 mm) when the non-invasive late activation zone nearly matches the CARTO data (average distance error 14 mm). Overall, the QRS complex was correctly reproduced by our method in all cases (r = 0.96). CONCLUSIONS: This study shows that new mapping technique can accurately reconstruct endocardial electrical activation maps based on 12-lead ECG and cardiac CT scan. The approach may be very useful in pre-procedural planning of device implantation and catheter ablation. Larger validation studies are however needed for confirming method accuracy at epicardial site. [Figure: see text]
format Online
Article
Text
id pubmed-10207848
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-102078482023-05-25 Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology Chmelevsky, M Zubarev, S Khamzin, S Dokuchaev, A Bazhutina, A Sinitca, A Budanova, M Auricchio, A Europace 9.3.7 - Noninvasive Diagnostic Methods FUNDING ACKNOWLEDGEMENTS: Type of funding sources: Private company. Main funding source(s): XSpline S.p.a. AIM: Noninvasive electrocardiographic mapping systems may require multichannel (150-250) ECG body surface recordings which is a huge limitation for the adoption into clinical practice. However, most of the currently available noninvasive mapping systems accurately represent epicardial activation. Over the last few years, various technical solutions have been implemented to increase the accuracy of ECG forward-inverse calculations including machine learning algorithms. We developed a novel 12-lead ECG-based, fully automated system for noninvasive full transmural (epi-endocardial) mapping. The aim of this study was to evaluate accuracy of this system in heart failure patients with typical LBBB. METHODS: Eight consecutive patients (median age: 65; 25-75% range 59-64; 5 male) with typical LBBB QRS morphology (QRS duration 146–224 ms), scheduled for CRT implantation underwent a cardiac CT scan and 12-lead ECG recording, followed by detailed bi-ventricular endocardial electroanatomical contact mapping (EAM). A median of 258 (181-576) local electrograms in LV and 86 (70-139) in RV were collected during EAM. Cardiac CT data were semiautomatically processed using a Unet-like neural network to obtain meshes containing the heart (each chamber with both endocardial and epicardial contour as well as coronary sinus and its branches), lungs and torso using different segmentation module. Noninvasive epi-endocardial activation maps were calculated using state-of-the-art mathematical models including machine learning methods. These data were compared with EAM from the invasive mapping system using Spearman correlation (r), mean absolute error (MAE) and relative distance metrics. RESULTS: All early and latest activation patterns were correctly identified (see figure). The average correlation (r) of endocardial activation maps was 0.92 for all cases (min-max: 0.82-0.96). MAE was rather small (9-15 mm) when the non-invasive late activation zone nearly matches the CARTO data (average distance error 14 mm). Overall, the QRS complex was correctly reproduced by our method in all cases (r = 0.96). CONCLUSIONS: This study shows that new mapping technique can accurately reconstruct endocardial electrical activation maps based on 12-lead ECG and cardiac CT scan. The approach may be very useful in pre-procedural planning of device implantation and catheter ablation. Larger validation studies are however needed for confirming method accuracy at epicardial site. [Figure: see text] Oxford University Press 2023-05-24 /pmc/articles/PMC10207848/ http://dx.doi.org/10.1093/europace/euad122.647 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle 9.3.7 - Noninvasive Diagnostic Methods
Chmelevsky, M
Zubarev, S
Khamzin, S
Dokuchaev, A
Bazhutina, A
Sinitca, A
Budanova, M
Auricchio, A
Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology
title Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology
title_full Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology
title_fullStr Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology
title_full_unstemmed Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology
title_short Clinical evaluation of the new 12-lead ECG noninvasive epi-endocardial mapping technology
title_sort clinical evaluation of the new 12-lead ecg noninvasive epi-endocardial mapping technology
topic 9.3.7 - Noninvasive Diagnostic Methods
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10207848/
http://dx.doi.org/10.1093/europace/euad122.647
work_keys_str_mv AT chmelevskym clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT zubarevs clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT khamzins clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT dokuchaeva clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT bazhutinaa clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT sinitcaa clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT budanovam clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology
AT auricchioa clinicalevaluationofthenew12leadecgnoninvasiveepiendocardialmappingtechnology