Cargando…

Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine

This study aimed to evaluate the effect of nicotine administration on the osseointegration of a superhydrophilic implants surface on rat tibiae. Thirty-two rats were used and divided into 2 groups according to the administration or not of nicotine: HH - Installation of implants with superhydrophilic...

Descripción completa

Detalles Bibliográficos
Autores principales: Pinotti, Felipe Eduardo, Aroni, Maurício Andrés Tinajero, de Oliveira, Guilherme José Pimentel Lopes, Silva, Bruno Luís Graciliano, Marcantonio, Elcio, Marcantonio, Rosemary Adriana Chiérici
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208290/
https://www.ncbi.nlm.nih.gov/pubmed/37194848
http://dx.doi.org/10.1590/0103-6440202305096
_version_ 1785046636677824512
author Pinotti, Felipe Eduardo
Aroni, Maurício Andrés Tinajero
de Oliveira, Guilherme José Pimentel Lopes
Silva, Bruno Luís Graciliano
Marcantonio, Elcio
Marcantonio, Rosemary Adriana Chiérici
author_facet Pinotti, Felipe Eduardo
Aroni, Maurício Andrés Tinajero
de Oliveira, Guilherme José Pimentel Lopes
Silva, Bruno Luís Graciliano
Marcantonio, Elcio
Marcantonio, Rosemary Adriana Chiérici
author_sort Pinotti, Felipe Eduardo
collection PubMed
description This study aimed to evaluate the effect of nicotine administration on the osseointegration of a superhydrophilic implants surface on rat tibiae. Thirty-two rats were used and divided into 2 groups according to the administration or not of nicotine: HH - Installation of implants with superhydrophilic surfaces in healthy animals; and HN - Installation of implants with superhydrophilic surfaces in animals subjected to nicotine administration. The animals were euthanized 15 and 45 days after implant placement (n = 8). Osseointegration was assessed by means of biomechanical analyses (removal torque), microcomputed tomography (volume of bone around the implants- %BV/TV), and histomorphometry (bone-implant contact -%BIC and the bone area between implant threads -%BBT). The animals subject to the nicotine administration presented lower removal torque than the control animals at the 45-day period (21.88 ± 2.80 Ncm vs. 17.88 ± 2.10 Ncm). The implants placed in the control rats presented higher %BIC (54.26 ± 6.59% vs. 39.25 ± 4.46%) and %BBT (50.57 ± 5.28% vs. 32.25 ± 5.24%) than the implants placed in nicotine animals at 15-day period. The nicotine administration reduces the osseointegration at 15 days, however, the superhydrophilic surface equalized the osseointegration in nicotine-exposed animals compared with healthy animals after 45 days of implant placement.
format Online
Article
Text
id pubmed-10208290
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-102082902023-05-25 Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine Pinotti, Felipe Eduardo Aroni, Maurício Andrés Tinajero de Oliveira, Guilherme José Pimentel Lopes Silva, Bruno Luís Graciliano Marcantonio, Elcio Marcantonio, Rosemary Adriana Chiérici Braz Dent J Article This study aimed to evaluate the effect of nicotine administration on the osseointegration of a superhydrophilic implants surface on rat tibiae. Thirty-two rats were used and divided into 2 groups according to the administration or not of nicotine: HH - Installation of implants with superhydrophilic surfaces in healthy animals; and HN - Installation of implants with superhydrophilic surfaces in animals subjected to nicotine administration. The animals were euthanized 15 and 45 days after implant placement (n = 8). Osseointegration was assessed by means of biomechanical analyses (removal torque), microcomputed tomography (volume of bone around the implants- %BV/TV), and histomorphometry (bone-implant contact -%BIC and the bone area between implant threads -%BBT). The animals subject to the nicotine administration presented lower removal torque than the control animals at the 45-day period (21.88 ± 2.80 Ncm vs. 17.88 ± 2.10 Ncm). The implants placed in the control rats presented higher %BIC (54.26 ± 6.59% vs. 39.25 ± 4.46%) and %BBT (50.57 ± 5.28% vs. 32.25 ± 5.24%) than the implants placed in nicotine animals at 15-day period. The nicotine administration reduces the osseointegration at 15 days, however, the superhydrophilic surface equalized the osseointegration in nicotine-exposed animals compared with healthy animals after 45 days of implant placement. Fundação Odontológica de Ribeirão Preto 2023-05-15 /pmc/articles/PMC10208290/ /pubmed/37194848 http://dx.doi.org/10.1590/0103-6440202305096 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
Pinotti, Felipe Eduardo
Aroni, Maurício Andrés Tinajero
de Oliveira, Guilherme José Pimentel Lopes
Silva, Bruno Luís Graciliano
Marcantonio, Elcio
Marcantonio, Rosemary Adriana Chiérici
Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
title Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
title_full Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
title_fullStr Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
title_full_unstemmed Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
title_short Osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
title_sort osseointegration of implants with superhydrophilic surfaces in rats with high serum levels of nicotine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208290/
https://www.ncbi.nlm.nih.gov/pubmed/37194848
http://dx.doi.org/10.1590/0103-6440202305096
work_keys_str_mv AT pinottifelipeeduardo osseointegrationofimplantswithsuperhydrophilicsurfacesinratswithhighserumlevelsofnicotine
AT aronimauricioandrestinajero osseointegrationofimplantswithsuperhydrophilicsurfacesinratswithhighserumlevelsofnicotine
AT deoliveiraguilhermejosepimentellopes osseointegrationofimplantswithsuperhydrophilicsurfacesinratswithhighserumlevelsofnicotine
AT silvabrunoluisgraciliano osseointegrationofimplantswithsuperhydrophilicsurfacesinratswithhighserumlevelsofnicotine
AT marcantonioelcio osseointegrationofimplantswithsuperhydrophilicsurfacesinratswithhighserumlevelsofnicotine
AT marcantoniorosemaryadrianachierici osseointegrationofimplantswithsuperhydrophilicsurfacesinratswithhighserumlevelsofnicotine