Cargando…

Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors

The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm(2) torque. The kinematics of the d...

Descripción completa

Detalles Bibliográficos
Autores principales: Monteiro-Netto, Renata de Castro, Braambati, Dieimes, Arruda-Vasconcelos, Rodrigo, Soares, Adriana de-Jesus, Frozoni, Marcos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208292/
https://www.ncbi.nlm.nih.gov/pubmed/37194853
http://dx.doi.org/10.1590/0103-6440202304953
_version_ 1785046637140246528
author Monteiro-Netto, Renata de Castro
Braambati, Dieimes
Arruda-Vasconcelos, Rodrigo
Soares, Adriana de-Jesus
Frozoni, Marcos
author_facet Monteiro-Netto, Renata de Castro
Braambati, Dieimes
Arruda-Vasconcelos, Rodrigo
Soares, Adriana de-Jesus
Frozoni, Marcos
author_sort Monteiro-Netto, Renata de Castro
collection PubMed
description The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm(2) torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values.
format Online
Article
Text
id pubmed-10208292
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-102082922023-05-25 Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors Monteiro-Netto, Renata de Castro Braambati, Dieimes Arruda-Vasconcelos, Rodrigo Soares, Adriana de-Jesus Frozoni, Marcos Braz Dent J Article The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm(2) torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values. Fundação Odontológica de Ribeirão Preto 2023-05-15 /pmc/articles/PMC10208292/ /pubmed/37194853 http://dx.doi.org/10.1590/0103-6440202304953 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
Monteiro-Netto, Renata de Castro
Braambati, Dieimes
Arruda-Vasconcelos, Rodrigo
Soares, Adriana de-Jesus
Frozoni, Marcos
Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors
title Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors
title_full Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors
title_fullStr Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors
title_full_unstemmed Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors
title_short Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors
title_sort evaluation of the rotary kinematics between actual and set speeds of x-smart plus, vdw.silver and iroot motors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208292/
https://www.ncbi.nlm.nih.gov/pubmed/37194853
http://dx.doi.org/10.1590/0103-6440202304953
work_keys_str_mv AT monteironettorenatadecastro evaluationoftherotarykinematicsbetweenactualandsetspeedsofxsmartplusvdwsilverandirootmotors
AT braambatidieimes evaluationoftherotarykinematicsbetweenactualandsetspeedsofxsmartplusvdwsilverandirootmotors
AT arrudavasconcelosrodrigo evaluationoftherotarykinematicsbetweenactualandsetspeedsofxsmartplusvdwsilverandirootmotors
AT soaresadrianadejesus evaluationoftherotarykinematicsbetweenactualandsetspeedsofxsmartplusvdwsilverandirootmotors
AT frozonimarcos evaluationoftherotarykinematicsbetweenactualandsetspeedsofxsmartplusvdwsilverandirootmotors