Cargando…

Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation

This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveO...

Descripción completa

Detalles Bibliográficos
Autores principales: Castro-Perez, Marco Antonio, Nabeshima, Cleber Keiti, Silva, Emmanuel. J. N. L., Valdivia, José Edgar, Gavini, Giulio, Machado, Manoel Eduardo de Lima
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208298/
https://www.ncbi.nlm.nih.gov/pubmed/37194855
http://dx.doi.org/10.1590/0103-6440202305231
_version_ 1785046638529609728
author Castro-Perez, Marco Antonio
Nabeshima, Cleber Keiti
Silva, Emmanuel. J. N. L.
Valdivia, José Edgar
Gavini, Giulio
Machado, Manoel Eduardo de Lima
author_facet Castro-Perez, Marco Antonio
Nabeshima, Cleber Keiti
Silva, Emmanuel. J. N. L.
Valdivia, José Edgar
Gavini, Giulio
Machado, Manoel Eduardo de Lima
author_sort Castro-Perez, Marco Antonio
collection PubMed
description This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation.
format Online
Article
Text
id pubmed-10208298
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-102082982023-05-25 Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation Castro-Perez, Marco Antonio Nabeshima, Cleber Keiti Silva, Emmanuel. J. N. L. Valdivia, José Edgar Gavini, Giulio Machado, Manoel Eduardo de Lima Braz Dent J Article This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation. Fundação Odontológica de Ribeirão Preto 2023-05-15 /pmc/articles/PMC10208298/ /pubmed/37194855 http://dx.doi.org/10.1590/0103-6440202305231 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
Castro-Perez, Marco Antonio
Nabeshima, Cleber Keiti
Silva, Emmanuel. J. N. L.
Valdivia, José Edgar
Gavini, Giulio
Machado, Manoel Eduardo de Lima
Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
title Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
title_full Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
title_fullStr Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
title_full_unstemmed Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
title_short Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
title_sort optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208298/
https://www.ncbi.nlm.nih.gov/pubmed/37194855
http://dx.doi.org/10.1590/0103-6440202305231
work_keys_str_mv AT castroperezmarcoantonio optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation
AT nabeshimacleberkeiti optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation
AT silvaemmanueljnl optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation
AT valdiviajoseedgar optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation
AT gavinigiulio optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation
AT machadomanoeleduardodelima optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation