Cargando…
Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation
This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveO...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Fundação Odontológica de Ribeirão Preto
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208298/ https://www.ncbi.nlm.nih.gov/pubmed/37194855 http://dx.doi.org/10.1590/0103-6440202305231 |
_version_ | 1785046638529609728 |
---|---|
author | Castro-Perez, Marco Antonio Nabeshima, Cleber Keiti Silva, Emmanuel. J. N. L. Valdivia, José Edgar Gavini, Giulio Machado, Manoel Eduardo de Lima |
author_facet | Castro-Perez, Marco Antonio Nabeshima, Cleber Keiti Silva, Emmanuel. J. N. L. Valdivia, José Edgar Gavini, Giulio Machado, Manoel Eduardo de Lima |
author_sort | Castro-Perez, Marco Antonio |
collection | PubMed |
description | This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation. |
format | Online Article Text |
id | pubmed-10208298 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Fundação Odontológica de Ribeirão Preto |
record_format | MEDLINE/PubMed |
spelling | pubmed-102082982023-05-25 Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation Castro-Perez, Marco Antonio Nabeshima, Cleber Keiti Silva, Emmanuel. J. N. L. Valdivia, José Edgar Gavini, Giulio Machado, Manoel Eduardo de Lima Braz Dent J Article This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation. Fundação Odontológica de Ribeirão Preto 2023-05-15 /pmc/articles/PMC10208298/ /pubmed/37194855 http://dx.doi.org/10.1590/0103-6440202305231 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License |
spellingShingle | Article Castro-Perez, Marco Antonio Nabeshima, Cleber Keiti Silva, Emmanuel. J. N. L. Valdivia, José Edgar Gavini, Giulio Machado, Manoel Eduardo de Lima Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
title | Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
title_full | Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
title_fullStr | Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
title_full_unstemmed | Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
title_short | Optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
title_sort | optimization of automated preparation of long oval-shaped root canals using supplementary instrumentation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208298/ https://www.ncbi.nlm.nih.gov/pubmed/37194855 http://dx.doi.org/10.1590/0103-6440202305231 |
work_keys_str_mv | AT castroperezmarcoantonio optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation AT nabeshimacleberkeiti optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation AT silvaemmanueljnl optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation AT valdiviajoseedgar optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation AT gavinigiulio optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation AT machadomanoeleduardodelima optimizationofautomatedpreparationoflongovalshapedrootcanalsusingsupplementaryinstrumentation |