Cargando…

Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids

Tetracycline is an antibiotic that has been prescribed for COVID-19 treatment, raising concerns about antibiotic resistance after long-term use. This study reported fluorescent polyvinylpyrrolidone-passivated iron oxide quantum dots (IO QDs) for detecting tetracycline in biological fluids for the fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sudewi, Sri, Chabib, Lutfi, Zulfajri, Muhammad, Gedda, Gangaraju, Huang, Genin G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taiwan Food and Drug Administration 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208663/
https://www.ncbi.nlm.nih.gov/pubmed/37224556
http://dx.doi.org/10.38212/2224-6614.3440
_version_ 1785046717859627008
author Sudewi, Sri
Chabib, Lutfi
Zulfajri, Muhammad
Gedda, Gangaraju
Huang, Genin G.
author_facet Sudewi, Sri
Chabib, Lutfi
Zulfajri, Muhammad
Gedda, Gangaraju
Huang, Genin G.
author_sort Sudewi, Sri
collection PubMed
description Tetracycline is an antibiotic that has been prescribed for COVID-19 treatment, raising concerns about antibiotic resistance after long-term use. This study reported fluorescent polyvinylpyrrolidone-passivated iron oxide quantum dots (IO QDs) for detecting tetracycline in biological fluids for the first time. The as-prepared IO QDs have an average size of 2.84 nm and exist a good stability under different conditions. The IO QDs’ tetracycline detection performance could be attributed to a combination of static quenching and inner filter effect. The IO QDs displayed high sensitivity and selectivity toward tetracycline and achieved a good linear relationship with the corresponding detection limit being 91.6 nM.
format Online
Article
Text
id pubmed-10208663
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Taiwan Food and Drug Administration
record_format MEDLINE/PubMed
spelling pubmed-102086632023-05-25 Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids Sudewi, Sri Chabib, Lutfi Zulfajri, Muhammad Gedda, Gangaraju Huang, Genin G. J Food Drug Anal Original Article Tetracycline is an antibiotic that has been prescribed for COVID-19 treatment, raising concerns about antibiotic resistance after long-term use. This study reported fluorescent polyvinylpyrrolidone-passivated iron oxide quantum dots (IO QDs) for detecting tetracycline in biological fluids for the first time. The as-prepared IO QDs have an average size of 2.84 nm and exist a good stability under different conditions. The IO QDs’ tetracycline detection performance could be attributed to a combination of static quenching and inner filter effect. The IO QDs displayed high sensitivity and selectivity toward tetracycline and achieved a good linear relationship with the corresponding detection limit being 91.6 nM. Taiwan Food and Drug Administration 2023-03-15 /pmc/articles/PMC10208663/ /pubmed/37224556 http://dx.doi.org/10.38212/2224-6614.3440 Text en © 2023 Taiwan Food and Drug Administration https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Original Article
Sudewi, Sri
Chabib, Lutfi
Zulfajri, Muhammad
Gedda, Gangaraju
Huang, Genin G.
Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
title Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
title_full Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
title_fullStr Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
title_full_unstemmed Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
title_short Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
title_sort polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208663/
https://www.ncbi.nlm.nih.gov/pubmed/37224556
http://dx.doi.org/10.38212/2224-6614.3440
work_keys_str_mv AT sudewisri polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids
AT chabiblutfi polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids
AT zulfajrimuhammad polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids
AT geddagangaraju polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids
AT huanggening polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids