Cargando…
Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids
Tetracycline is an antibiotic that has been prescribed for COVID-19 treatment, raising concerns about antibiotic resistance after long-term use. This study reported fluorescent polyvinylpyrrolidone-passivated iron oxide quantum dots (IO QDs) for detecting tetracycline in biological fluids for the fi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taiwan Food and Drug Administration
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208663/ https://www.ncbi.nlm.nih.gov/pubmed/37224556 http://dx.doi.org/10.38212/2224-6614.3440 |
_version_ | 1785046717859627008 |
---|---|
author | Sudewi, Sri Chabib, Lutfi Zulfajri, Muhammad Gedda, Gangaraju Huang, Genin G. |
author_facet | Sudewi, Sri Chabib, Lutfi Zulfajri, Muhammad Gedda, Gangaraju Huang, Genin G. |
author_sort | Sudewi, Sri |
collection | PubMed |
description | Tetracycline is an antibiotic that has been prescribed for COVID-19 treatment, raising concerns about antibiotic resistance after long-term use. This study reported fluorescent polyvinylpyrrolidone-passivated iron oxide quantum dots (IO QDs) for detecting tetracycline in biological fluids for the first time. The as-prepared IO QDs have an average size of 2.84 nm and exist a good stability under different conditions. The IO QDs’ tetracycline detection performance could be attributed to a combination of static quenching and inner filter effect. The IO QDs displayed high sensitivity and selectivity toward tetracycline and achieved a good linear relationship with the corresponding detection limit being 91.6 nM. |
format | Online Article Text |
id | pubmed-10208663 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Taiwan Food and Drug Administration |
record_format | MEDLINE/PubMed |
spelling | pubmed-102086632023-05-25 Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids Sudewi, Sri Chabib, Lutfi Zulfajri, Muhammad Gedda, Gangaraju Huang, Genin G. J Food Drug Anal Original Article Tetracycline is an antibiotic that has been prescribed for COVID-19 treatment, raising concerns about antibiotic resistance after long-term use. This study reported fluorescent polyvinylpyrrolidone-passivated iron oxide quantum dots (IO QDs) for detecting tetracycline in biological fluids for the first time. The as-prepared IO QDs have an average size of 2.84 nm and exist a good stability under different conditions. The IO QDs’ tetracycline detection performance could be attributed to a combination of static quenching and inner filter effect. The IO QDs displayed high sensitivity and selectivity toward tetracycline and achieved a good linear relationship with the corresponding detection limit being 91.6 nM. Taiwan Food and Drug Administration 2023-03-15 /pmc/articles/PMC10208663/ /pubmed/37224556 http://dx.doi.org/10.38212/2224-6614.3440 Text en © 2023 Taiwan Food and Drug Administration https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ). |
spellingShingle | Original Article Sudewi, Sri Chabib, Lutfi Zulfajri, Muhammad Gedda, Gangaraju Huang, Genin G. Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
title | Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
title_full | Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
title_fullStr | Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
title_full_unstemmed | Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
title_short | Polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
title_sort | polyvinylpyrrolidone-passivated fluorescent iron oxide quantum dots for turn-off detection of tetracycline in biological fluids |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208663/ https://www.ncbi.nlm.nih.gov/pubmed/37224556 http://dx.doi.org/10.38212/2224-6614.3440 |
work_keys_str_mv | AT sudewisri polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids AT chabiblutfi polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids AT zulfajrimuhammad polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids AT geddagangaraju polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids AT huanggening polyvinylpyrrolidonepassivatedfluorescentironoxidequantumdotsforturnoffdetectionoftetracyclineinbiologicalfluids |