Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles

BACKGROUND: Air embolism (AE), especially when affecting the brain, is an underrated and potentially life-threatening complication in various endovascular interventions. This study aims to investigate experimental AEs using a new model to generate micro air bubbles (MAB), to assess the impact of a c...

Descripción completa

Detalles Bibliográficos
Autores principales: C. Schaefer, Tabea, Greive, Svenja, Heiland, Sabine, Kramer, Martin, Bendszus, Martin, Vollherbst, Dominik F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10209548/
https://www.ncbi.nlm.nih.gov/pubmed/35255747
http://dx.doi.org/10.1177/15266028221082010
_version_ 1785046899535904768
author C. Schaefer, Tabea
Greive, Svenja
Heiland, Sabine
Kramer, Martin
Bendszus, Martin
Vollherbst, Dominik F.
author_facet C. Schaefer, Tabea
Greive, Svenja
Heiland, Sabine
Kramer, Martin
Bendszus, Martin
Vollherbst, Dominik F.
author_sort C. Schaefer, Tabea
collection PubMed
description BACKGROUND: Air embolism (AE), especially when affecting the brain, is an underrated and potentially life-threatening complication in various endovascular interventions. This study aims to investigate experimental AEs using a new model to generate micro air bubbles (MAB), to assess the impact of a catheter on these MAB, and to demonstrate the applicability of this model in vivo. MATERIALS AND METHODS: Micro air bubbles were created using a system based on microfluidic channels. The MAB were detected and analyzed automatically. Micro air bubbles, with a target size of 85 µm, were generated and injected through a microcatheter. The MAB diameters proximal and distal to the catheter were assessed and compared. In a subsequent in vivo application, 2000 MAB were injected into the aorta (at the aortic valve) and into the common carotid artery (CCA) of a rat, respectively, using a microcatheter, resembling AE occurring during cardiovascular interventions. RESULTS: Micro air bubbles with a highly calibrated size could be successfully generated (median: 85.5 µm, SD 1.9 µm). After passage of the microcatheter, the MAB were similar in diameter (median: 86.6 µm) but at a lower number (60.1% of the injected MAB) and a substantially higher scattering of diameters (SD 29.6 µm). In vivo injection of MAB into the aorta resulted in cerebral microinfarctions in both hemispheres, whereas injection into the CCA caused exclusively ipsilateral microinfarctions. CONCLUSION: Using this new AE model, MAB can be generated precisely and reproducibly, resulting in cerebral microinfarctions. This model is feasible for further studies on the pathophysiology and prevention of AE in cardiovascular procedures.
format Online
Article
Text
id pubmed-10209548
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-102095482023-05-26 Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles C. Schaefer, Tabea Greive, Svenja Heiland, Sabine Kramer, Martin Bendszus, Martin Vollherbst, Dominik F. J Endovasc Ther Experimental Investigations BACKGROUND: Air embolism (AE), especially when affecting the brain, is an underrated and potentially life-threatening complication in various endovascular interventions. This study aims to investigate experimental AEs using a new model to generate micro air bubbles (MAB), to assess the impact of a catheter on these MAB, and to demonstrate the applicability of this model in vivo. MATERIALS AND METHODS: Micro air bubbles were created using a system based on microfluidic channels. The MAB were detected and analyzed automatically. Micro air bubbles, with a target size of 85 µm, were generated and injected through a microcatheter. The MAB diameters proximal and distal to the catheter were assessed and compared. In a subsequent in vivo application, 2000 MAB were injected into the aorta (at the aortic valve) and into the common carotid artery (CCA) of a rat, respectively, using a microcatheter, resembling AE occurring during cardiovascular interventions. RESULTS: Micro air bubbles with a highly calibrated size could be successfully generated (median: 85.5 µm, SD 1.9 µm). After passage of the microcatheter, the MAB were similar in diameter (median: 86.6 µm) but at a lower number (60.1% of the injected MAB) and a substantially higher scattering of diameters (SD 29.6 µm). In vivo injection of MAB into the aorta resulted in cerebral microinfarctions in both hemispheres, whereas injection into the CCA caused exclusively ipsilateral microinfarctions. CONCLUSION: Using this new AE model, MAB can be generated precisely and reproducibly, resulting in cerebral microinfarctions. This model is feasible for further studies on the pathophysiology and prevention of AE in cardiovascular procedures. SAGE Publications 2022-03-08 2023-06 /pmc/articles/PMC10209548/ /pubmed/35255747 http://dx.doi.org/10.1177/15266028221082010 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Experimental Investigations
C. Schaefer, Tabea
Greive, Svenja
Heiland, Sabine
Kramer, Martin
Bendszus, Martin
Vollherbst, Dominik F.
Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles
title Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles
title_full Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles
title_fullStr Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles
title_full_unstemmed Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles
title_short Investigation of Experimental Endovascular Air Embolisms Using a New Model for the Generation and Detection of Highly Calibrated Micro Air Bubbles
title_sort investigation of experimental endovascular air embolisms using a new model for the generation and detection of highly calibrated micro air bubbles
topic Experimental Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10209548/
https://www.ncbi.nlm.nih.gov/pubmed/35255747
http://dx.doi.org/10.1177/15266028221082010
work_keys_str_mv AT cschaefertabea investigationofexperimentalendovascularairembolismsusinganewmodelforthegenerationanddetectionofhighlycalibratedmicroairbubbles
AT greivesvenja investigationofexperimentalendovascularairembolismsusinganewmodelforthegenerationanddetectionofhighlycalibratedmicroairbubbles
AT heilandsabine investigationofexperimentalendovascularairembolismsusinganewmodelforthegenerationanddetectionofhighlycalibratedmicroairbubbles
AT kramermartin investigationofexperimentalendovascularairembolismsusinganewmodelforthegenerationanddetectionofhighlycalibratedmicroairbubbles
AT bendszusmartin investigationofexperimentalendovascularairembolismsusinganewmodelforthegenerationanddetectionofhighlycalibratedmicroairbubbles
AT vollherbstdominikf investigationofexperimentalendovascularairembolismsusinganewmodelforthegenerationanddetectionofhighlycalibratedmicroairbubbles