Cargando…
Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation
INTRODUCTION: In morphologically normal-appearing inner ears, measurements of the distance between the round window and carotid canal (RCD), the maximum diameter of the basal turn of the cochlea next to the round window (BD), and the thickness of the promontory (PT) just lateral to the basal turn ma...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mashhad University of Medical Sciences
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10209812/ https://www.ncbi.nlm.nih.gov/pubmed/37251294 http://dx.doi.org/10.22038/IJORL.2023.65579.3249 |
_version_ | 1785046958032814080 |
---|---|
author | Kavitha, Yellur Joish, Upendra Kumar |
author_facet | Kavitha, Yellur Joish, Upendra Kumar |
author_sort | Kavitha, Yellur |
collection | PubMed |
description | INTRODUCTION: In morphologically normal-appearing inner ears, measurements of the distance between the round window and carotid canal (RCD), the maximum diameter of the basal turn of the cochlea next to the round window (BD), and the thickness of the promontory (PT) just lateral to the basal turn may be used as guide for safe cochleostomy and implant placement. MATERIALS AND METHODS: From January to March 2022, a cross-sectional observational study was carried out in a tertiary care hospital. The round window to carotid canal distance (RCD), the largest diameter of the cochlea's basal turn next to the round window (BD), and the thickness of the promontory immediately lateral to the basal turn (PT) were measured using CT temporal bone images of 150 persons without cochlear abnormalities. The values obtained were compared using Paired T-test for significance of difference between both genders and sides. RESULTS: A total of 150 participants—75 men and 75 women—with a mean age of 37.5 years were enrolled in the study. With a range of 7.18 mm to 10.52 mm, the mean RCD was 8.84 mm (SD 0.8 mm). The mean BD was 2.27 mm (SD 0.4 mm), while the mean PT was 1.15 mm (SD 0. mm). The values obtained did not differ significantly in both the genders and the right and left sides (p = 0.37 and 0.24, respectively). CONCLUSION: The present study has defined and calculated pertinent measures at cochleostomy site that will aid safe electrode insertion and prevent misplacement. |
format | Online Article Text |
id | pubmed-10209812 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Mashhad University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-102098122023-05-26 Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation Kavitha, Yellur Joish, Upendra Kumar Iran J Otorhinolaryngol Original Article INTRODUCTION: In morphologically normal-appearing inner ears, measurements of the distance between the round window and carotid canal (RCD), the maximum diameter of the basal turn of the cochlea next to the round window (BD), and the thickness of the promontory (PT) just lateral to the basal turn may be used as guide for safe cochleostomy and implant placement. MATERIALS AND METHODS: From January to March 2022, a cross-sectional observational study was carried out in a tertiary care hospital. The round window to carotid canal distance (RCD), the largest diameter of the cochlea's basal turn next to the round window (BD), and the thickness of the promontory immediately lateral to the basal turn (PT) were measured using CT temporal bone images of 150 persons without cochlear abnormalities. The values obtained were compared using Paired T-test for significance of difference between both genders and sides. RESULTS: A total of 150 participants—75 men and 75 women—with a mean age of 37.5 years were enrolled in the study. With a range of 7.18 mm to 10.52 mm, the mean RCD was 8.84 mm (SD 0.8 mm). The mean BD was 2.27 mm (SD 0.4 mm), while the mean PT was 1.15 mm (SD 0. mm). The values obtained did not differ significantly in both the genders and the right and left sides (p = 0.37 and 0.24, respectively). CONCLUSION: The present study has defined and calculated pertinent measures at cochleostomy site that will aid safe electrode insertion and prevent misplacement. Mashhad University of Medical Sciences 2023-05 /pmc/articles/PMC10209812/ /pubmed/37251294 http://dx.doi.org/10.22038/IJORL.2023.65579.3249 Text en https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kavitha, Yellur Joish, Upendra Kumar Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation |
title | Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation |
title_full | Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation |
title_fullStr | Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation |
title_full_unstemmed | Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation |
title_short | Morphometry around Cochleostomy Site to Aid Safe Cochlear Implantation |
title_sort | morphometry around cochleostomy site to aid safe cochlear implantation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10209812/ https://www.ncbi.nlm.nih.gov/pubmed/37251294 http://dx.doi.org/10.22038/IJORL.2023.65579.3249 |
work_keys_str_mv | AT kavithayellur morphometryaroundcochleostomysitetoaidsafecochlearimplantation AT joishupendrakumar morphometryaroundcochleostomysitetoaidsafecochlearimplantation |